Darren Drosdowech
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Darren Drosdowech has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Milej
Western University, Department of Medical Biophysics, London, Ontario, Canada
2 shared publications - Farah Kamar
Western University, Department of Medical Biophysics, London, Ontario, Canada
2 shared publications - Jason Chui
Department of Anesthesiology, Pharmacology and Therapeutics, Vancouver General Hospital and University of British Columbia, British Columbia, Canada
2 shared publications - Keith. St. Lawrence
Western University, Department of Medical Biophysics, London, Ontario, Canada
2 shared publications - Leena N. Shoemaker
Western University, Department of Medical Biophysics, London, Ontario, Canada
2 shared publications - Ruby Grewal
Roth | McFarlane Hand and Upper Limb Centre, St Joseph’s Healthcare Centre , London, Ontario
2 shared publications
Latest Publications
- 16 July 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (5) , 1117-1131
Cerebral Hemodynamic and Metabolic Responses to Anesthesia and Vasopressors in Adult Shoulder Surgery: A 2 × 2 Factorial Design Randomized Controlled Trial with Light-based Neuromonitoring (CHEM-FACT Study)
Background: Ephedrine has been suggested to improve cerebral microcirculation and perfusion compared with phenylephrine. However, prospective intraoperative data are lacking, and possible interactions with anesthetic choice remain untested. Methods: Forty adults undergoing shoulder surgery in the beach chair position were recruited between February and November 2024 at St. Joseph’s Hospital (London, Canada). Patients were randomized in a 2 × 2 factorial design to anesthetic maintenance (propofol vs . sevoflurane) and vasopressor strategy (phenylephrine infusion vs . ephedrine boluses). Relative tissue oxygenation saturation (rStO 2 ) and the relative cerebral metabolic rate of oxygen (rCMRO 2 ), the coprimary outcomes, were monitored using an in-house hybrid optical system combining time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy. Only data from the first 30 min after positioning were analyzed. Outcomes and interactions were assessed using linear mixed-effects models. Results: Of the 40 patients, 39 were analyzed. Neither anesthetic nor vasopressor choice showed a significant main effect on average rStO 2 or rCMRO 2 during the 30-min period. However, analysis of temporal changes revealed rStO 2 declined over time (β = –0.005 per minute; χ 2 (1) = 10.2; P = 0.001), while rCMRO 2 increased (β = 3.2 per minute; χ 2 (1) = 35.2; P < 0.001). There was a time by vasopressor interaction for rStO 2 (β = –0.0014; χ 2 (1) = 8.4; P = 0.004), with phenylephrine producing a 9% greater decline during 30 min compared to ephedrine, while for relative rCMRO 2 (β = 2.2; 95% CI, 0.6 to 3.8; P = 0.007), phenylephrine produced a 70% increase during 30 min. Conclusions: This trial found no overall effect of anesthetic or vasopressor choice on rStO 2 or rCMRO 2 during the first 30 min of surgery, suggesting that initial cerebral physiologic responses were comparable across treatment combinations. However, phenylephrine was associated with progressive cerebral desaturation and increasing metabolic demand over time.
- 16 July 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (5) , 1117-1131
Cerebral Hemodynamic and Metabolic Responses to Anesthesia and Vasopressors in Adult Shoulder Surgery: A 2 × 2 Factorial Design Randomized Controlled Trial with Light-based Neuromonitoring (CHEM-FACT Study)
Background: Ephedrine has been suggested to improve cerebral microcirculation and perfusion compared with phenylephrine. However, prospective intraoperative data are lacking, and possible interactions with anesthetic choice remain untested. Methods: Forty adults undergoing shoulder surgery in the beach chair position were recruited between February and November 2024 at St. Joseph’s Hospital (London, Canada). Patients were randomized in a 2 × 2 factorial design to anesthetic maintenance (propofol vs . sevoflurane) and vasopressor strategy (phenylephrine infusion vs . ephedrine boluses). Relative tissue oxygenation saturation (rStO 2 ) and the relative cerebral metabolic rate of oxygen (rCMRO 2 ), the coprimary outcomes, were monitored using an in-house hybrid optical system combining time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy. Only data from the first 30 min after positioning were analyzed. Outcomes and interactions were assessed using linear mixed-effects models. Results: Of the 40 patients, 39 were analyzed. Neither anesthetic nor vasopressor choice showed a significant main effect on average rStO 2 or rCMRO 2 during the 30-min period. However, analysis of temporal changes revealed rStO 2 declined over time (β = –0.005 per minute; χ 2 (1) = 10.2; P = 0.001), while rCMRO 2 increased (β = 3.2 per minute; χ 2 (1) = 35.2; P < 0.001). There was a time by vasopressor interaction for rStO 2 (β = –0.0014; χ 2 (1) = 8.4; P = 0.004), with phenylephrine producing a 9% greater decline during 30 min compared to ephedrine, while for relative rCMRO 2 (β = 2.2; 95% CI, 0.6 to 3.8; P = 0.007), phenylephrine produced a 70% increase during 30 min. Conclusions: This trial found no overall effect of anesthetic or vasopressor choice on rStO 2 or rCMRO 2 during the first 30 min of surgery, suggesting that initial cerebral physiologic responses were comparable across treatment combinations. However, phenylephrine was associated with progressive cerebral desaturation and increasing metabolic demand over time.
- Open Access
- 3 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33302-15
Assessing changes in regional cerebral hemodynamics in adults with a high-density full-head coverage time-resolved near-infrared spectroscopy device
SignificanceCerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS).AimThis work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery.ApproachThe Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts.ResultsIn the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed.ConclusionsThe Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.
- 3 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33302-15
Open AccessAssessing changes in regional cerebral hemodynamics in adults with a high-density full-head coverage time-resolved near-infrared spectroscopy device
SignificanceCerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS).AimThis work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery.ApproachThe Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts.ResultsIn the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed.ConclusionsThe Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (1)
Interscalene Block Catheter Knotting in Brachial Plexus Following Elective Reverse Total Shoulder Arthroplasty
Case: A male patient in his late 50s had attempted removal of an interscalene block catheter after reverse total shoulder arthroplasty. Atypical pain and resistance raised concern for entrapment in the brachial plexus, requiring surgical exploration. It was found to have knotted in the anterior and posterior divisions of the upper trunk of the brachial plexus. Under direct visualization, the catheter was removed and the brachial plexus was unharmed. Conclusion: This case raises awareness that if unexpected pain or resistance is encountered during nerve block catheter removal, it is vital to pause and evaluate the possibility of entrapment in neural structures.
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (1)
Interscalene Block Catheter Knotting in Brachial Plexus Following Elective Reverse Total Shoulder Arthroplasty
Case: A male patient in his late 50s had attempted removal of an interscalene block catheter after reverse total shoulder arthroplasty. Atypical pain and resistance raised concern for entrapment in the brachial plexus, requiring surgical exploration. It was found to have knotted in the anterior and posterior divisions of the upper trunk of the brachial plexus. Under direct visualization, the catheter was removed and the brachial plexus was unharmed. Conclusion: This case raises awareness that if unexpected pain or resistance is encountered during nerve block catheter removal, it is vital to pause and evaluate the possibility of entrapment in neural structures.
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (10) , e327-e333
Effect of Concomitant Elbow Injuries on the Outcomes of Radial Head Arthroplasty: A Cohort Comparison
Objectives: To compare physical impairments and patient-reported outcomes in patients after simple and complex elbow injuries who were treated with radial head arthroplasty. Design: Prospective. Setting: Quaternary upper extremity referral hospital. Patients/Participants: 148 patients with isolated elbow trauma and no previous injury to the elbow were prospectively enrolled after radial head arthroplasty for an acute unreconstructable fracture. Injury patterns were classified as simple or complex based on the presence or absence of associated elbow fractures and/or dislocation. Intervention: Radial head arthroplasty. Main Outcome Measurements: Patient-Rated Elbow Evaluation (PREE), Disability of the Arm, Shoulder, and Hand, range of motion (ROM), and Biodex measurements. Results: At a minimum 1-year follow-up PREE and Disability of the Arm, Shoulder, and Hand, and ROM and strength values were similar. Forty-four patients evaluated at a mean of 7 years demonstrated no effect of injury pattern on clinical outcomes at any time point. Continued statistical improvements in PREE, supination ROM, and flexion ROM at medium term compared with earlier follow-up were observed. Eight patients required secondary surgery, 2 in the simple injury group and 6 complex injury patients. Conclusions: Concomitant elbow injuries do not affect the longer term outcomes of patients with unreconstructable radial head fractures requiring radial head arthroplasty. Patient outcomes continued to improve beyond 2 years of follow-up. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (10) , e327-e333
Effect of Concomitant Elbow Injuries on the Outcomes of Radial Head Arthroplasty: A Cohort Comparison
Objectives: To compare physical impairments and patient-reported outcomes in patients after simple and complex elbow injuries who were treated with radial head arthroplasty. Design: Prospective. Setting: Quaternary upper extremity referral hospital. Patients/Participants: 148 patients with isolated elbow trauma and no previous injury to the elbow were prospectively enrolled after radial head arthroplasty for an acute unreconstructable fracture. Injury patterns were classified as simple or complex based on the presence or absence of associated elbow fractures and/or dislocation. Intervention: Radial head arthroplasty. Main Outcome Measurements: Patient-Rated Elbow Evaluation (PREE), Disability of the Arm, Shoulder, and Hand, range of motion (ROM), and Biodex measurements. Results: At a minimum 1-year follow-up PREE and Disability of the Arm, Shoulder, and Hand, and ROM and strength values were similar. Forty-four patients evaluated at a mean of 7 years demonstrated no effect of injury pattern on clinical outcomes at any time point. Continued statistical improvements in PREE, supination ROM, and flexion ROM at medium term compared with earlier follow-up were observed. Eight patients required secondary surgery, 2 in the simple injury group and 6 complex injury patients. Conclusions: Concomitant elbow injuries do not affect the longer term outcomes of patients with unreconstructable radial head fractures requiring radial head arthroplasty. Patient outcomes continued to improve beyond 2 years of follow-up. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 6 May 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 147
A randomized controlled trial of nonoperative treatment versus open reduction and internal fixation for stable, displaced, partial articular fractures of the radial head: the RAMBO trial
The choice between operative or nonoperative treatment is questioned for partial articular fractures of the radial head that have at least 2 millimeters of articular step-off on at least one radiograph (defined as displaced), but less than 2 millimeter of gap between the fragments (defined as stable) and that are not associated with an elbow dislocation, interosseous ligament injury, or other fractures. These kinds of fractures are often classified as Mason type-2 fractures. Retrospective comparative studies suggest that operative treatment might be better than nonoperative treatment, but the long-term results of nonoperative treatment are very good. Most experts agree that problems like reduced range of motion, painful crepitation, nonunion or bony ankylosis are infrequent with both nonoperative and operative treatment of an isolated displaced partial articular fracture of the radial head, but determining which patients will have problems is difficult. A prospective, randomized comparison would help minimize bias and determine the balance between operative and nonoperative risks and benefits. The RAMBO trial (Radial Head – Amsterdam – Amphia – Boston - Others) is an international prospective, randomized, multicenter trial. The primary objective of this study is to compare patient related outcome defined by the ‘Disabilities of Arm, Shoulder and Hand (DASH) score’ twelve months after injury between operative and nonoperative treated patients. Adult patients with partial articular fractures of the radial head that comprise at least 1/3rd of the articular surface, have ≥ 2 millimeters of articular step-off but less than 2 millimeter of gap between the fragments will be enrolled. Secondary outcome measures will be the Mayo Elbow Performance Index (MEPI), the Oxford Elbow Score (OES), pain intensity through the ‘Numeric Rating Scale’, range of motion (flexion arc and rotational arc), radiographic appearance of the fracture (heterotopic ossification, radiocapitellar and ulnohumeral arthrosis, fracture healing, and signs of implant loosening or breakage) and adverse events (infection, nerve injury, secondary interventions) after one year. The successful completion of this trial will provide evidence on the best treatment for stable, displaced, partial articular fractures of the radial head. The trial is registered at the Dutch Trial Register: NTR3413 .
- 6 May 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 147
Open AccessA randomized controlled trial of nonoperative treatment versus open reduction and internal fixation for stable, displaced, partial articular fractures of the radial head: the RAMBO trial
The choice between operative or nonoperative treatment is questioned for partial articular fractures of the radial head that have at least 2 millimeters of articular step-off on at least one radiograph (defined as displaced), but less than 2 millimeter of gap between the fragments (defined as stable) and that are not associated with an elbow dislocation, interosseous ligament injury, or other fractures. These kinds of fractures are often classified as Mason type-2 fractures. Retrospective comparative studies suggest that operative treatment might be better than nonoperative treatment, but the long-term results of nonoperative treatment are very good. Most experts agree that problems like reduced range of motion, painful crepitation, nonunion or bony ankylosis are infrequent with both nonoperative and operative treatment of an isolated displaced partial articular fracture of the radial head, but determining which patients will have problems is difficult. A prospective, randomized comparison would help minimize bias and determine the balance between operative and nonoperative risks and benefits. The RAMBO trial (Radial Head – Amsterdam – Amphia – Boston - Others) is an international prospective, randomized, multicenter trial. The primary objective of this study is to compare patient related outcome defined by the ‘Disabilities of Arm, Shoulder and Hand (DASH) score’ twelve months after injury between operative and nonoperative treated patients. Adult patients with partial articular fractures of the radial head that comprise at least 1/3rd of the articular surface, have ≥ 2 millimeters of articular step-off but less than 2 millimeter of gap between the fragments will be enrolled. Secondary outcome measures will be the Mayo Elbow Performance Index (MEPI), the Oxford Elbow Score (OES), pain intensity through the ‘Numeric Rating Scale’, range of motion (flexion arc and rotational arc), radiographic appearance of the fracture (heterotopic ossification, radiocapitellar and ulnohumeral arthrosis, fracture healing, and signs of implant loosening or breakage) and adverse events (infection, nerve injury, secondary interventions) after one year. The successful completion of this trial will provide evidence on the best treatment for stable, displaced, partial articular fractures of the radial head. The trial is registered at the Dutch Trial Register: NTR3413 .