SKStacey Kennerly

Stacey Kennerly

*This is an algorithmically generated author record based on publicly available information.

Stacey Kennerly has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep Implanted SiC Super-Junction Technology

    by Reza Ghandi, Collin Hitchcock, Stacey Kennerly

    GE Aerospace is developing a novel fabrication method for >3.3 kV devices using ultra-high energy deep implantation and epitaxial overgrowth. We report succesful fabrication of the world’s first 3.5 kV SiC SJ deep implanted junction barrier Schottky (JBS) diodes and 5 kV SiC SJ deep implanted MOSFETs, which exhibit record low specific on-resistance (Ron,sp) and superior breakdown voltages. This innovative method offers a scalable path towards more efficient medium-voltage converters, outperforming traditional SiC unipolar devices.


  • Open Access

    Analysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions with Silicon Energy-Filter for Ion Implantation

    by Ze Yu Chen, Qian Yu Cheng, Shan Shan Hu, Balaji Raghothamachar, Charles Carlson, Dannie Steski, Thomas Kubley, Florian Krippendorf, Michael Rüb, Robert Koch, et al.

    Multi-step high energy ion implantation enables uniform doping to depths up to 12 µm in 4H-SiC epiwafers for superjunction devices but extent of lattice damage is of significant concern for device fabrication. 4H-SiC wafers with 12 µm thick epilayers implanted with Al ions at a concentration of 5 x 1016 cm-3 using the Tandem Van de Graaff accelerator at Brookhaven National Laboratory across an energy range of 13.8 to 65.7 MeV and at different temperatures: room temperature, 300 °C, and 600 °C were analyzed by reciprocal space mapping measurements. Implanted layers exhibited tensile strains that decreased with increasing implantation temperature indicating dynamic annealing effect reduces lattice damage. On annealing at 1700 °C, for recovery of the lattice strain, RSM measurements show that the highest implantation temperatures have the lowest residual strains. In addition, the use of a Silicon Energy-Filter for Ion Implantation (EFII) for Al implantation in a single stage to the depth of 15µm is found to further reduce lattice strain compared to wafers implanted without EFII to the same doping concentration. This preliminary study will assist in optimizing the implantation and annealing conditions for the development of superjunction devices.

  • Open Access

    Experimental Demonstration and Analysis of 3.3kV 4H-SiC Common-Drain Bidirectional Charge-Balanced Power MOSFETs

    by Mohamed Torky, Zhaowen He, Collin Hitchcock, Reza Ghandi, Stacey Kennerly, T. Paul Chow

    By using 4H-SiC packaged Charge-Balanced (CB) MOSFET, we have experimentally demonstrated a 3.3kV 4H-SiC common-drain bidirectional (BD) CB power MOSFET and measured its static and dynamic characteristics compared to its unidirectional counterpart. We show that the BD CB MOSFET conducts and blocks at the first and third quadrants with the appropriate gate bias with an on-state resistance double its unidirectional counterpart, while its switching energies are 12 (19) and 34 (12) mJ/cm2for BD CB MOSFET (UD CB MOSFET).


  • Open Access

    Analysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions at Elevated Temperatures

    by Ze Yu Chen, Yafei Liu, Qian Yu Cheng, Shanshan Hu, Balaji Raghothamachar, Reza Ghandi, Stacey Kennerly, Charles Carlson, Dannie Steski, Michael Dudley

    4H-SiC wafers with 12 µm epilayers were blanket implanted to a depth of 12 µm with 5 x 1016 cm-3 Al ions via Tandem Van de Graaff accelerator located at Brookhaven National Laboratory with energy range of 13.8 to 65.7 MeV at room temperature, 300 °C and 600 °C. High resolution X-ray diffraction measurements reveal the implanted layers are characterized by tensile strains. However, the dynamic annealing process reduces the level of tensile strains as the temperature of implantation is increased. Analysis indicates that the implant temperature of 600 °C is not sufficient to minimize lattice damage due to implantation and a higher implantation temperature will be required. This preliminary experiment will guide the optimization of implantation conditions for fabricating superjunction devices.