Stacey Kennerly
Stacey Kennerly has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Reza Ghandi
GE Aerospace Research
2 shared publications - Shanshan Hu
Stony Brook University
2 shared publications - Zeyu Chen
Stony Brook University
2 shared publications - Balaji Raghothamachar
Stony Brook University
1 shared publication - Balaji Raghothamachar
Stony Brook University
1 shared publication - Charles Carlson
Brookhaven National Laboratory
1 shared publication
Latest Publications
- Open Access
- 8 September 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1158, 75-79
Deep Implanted SiC Super-Junction Technology
GE Aerospace is developing a novel fabrication method for >3.3 kV devices using ultra-high energy deep implantation and epitaxial overgrowth. We report succesful fabrication of the world’s first 3.5 kV SiC SJ deep implanted junction barrier Schottky (JBS) diodes and 5 kV SiC SJ deep implanted MOSFETs, which exhibit record low specific on-resistance (Ron,sp) and superior breakdown voltages. This innovative method offers a scalable path towards more efficient medium-voltage converters, outperforming traditional SiC unipolar devices.
- 8 September 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1158, 75-79
Open AccessDeep Implanted SiC Super-Junction Technology
GE Aerospace is developing a novel fabrication method for >3.3 kV devices using ultra-high energy deep implantation and epitaxial overgrowth. We report succesful fabrication of the world’s first 3.5 kV SiC SJ deep implanted junction barrier Schottky (JBS) diodes and 5 kV SiC SJ deep implanted MOSFETs, which exhibit record low specific on-resistance (Ron,sp) and superior breakdown voltages. This innovative method offers a scalable path towards more efficient medium-voltage converters, outperforming traditional SiC unipolar devices.
- Open Access
- 5 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 375, 29-34
Analysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions with Silicon Energy-Filter for Ion Implantation
Multi-step high energy ion implantation enables uniform doping to depths up to 12 µm in 4H-SiC epiwafers for superjunction devices but extent of lattice damage is of significant concern for device fabrication. 4H-SiC wafers with 12 µm thick epilayers implanted with Al ions at a concentration of 5 x 1016 cm-3 using the Tandem Van de Graaff accelerator at Brookhaven National Laboratory across an energy range of 13.8 to 65.7 MeV and at different temperatures: room temperature, 300 °C, and 600 °C were analyzed by reciprocal space mapping measurements. Implanted layers exhibited tensile strains that decreased with increasing implantation temperature indicating dynamic annealing effect reduces lattice damage. On annealing at 1700 °C, for recovery of the lattice strain, RSM measurements show that the highest implantation temperatures have the lowest residual strains. In addition, the use of a Silicon Energy-Filter for Ion Implantation (EFII) for Al implantation in a single stage to the depth of 15µm is found to further reduce lattice strain compared to wafers implanted without EFII to the same doping concentration. This preliminary study will assist in optimizing the implantation and annealing conditions for the development of superjunction devices.
- 5 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 375, 29-34
Open AccessAnalysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions with Silicon Energy-Filter for Ion Implantation
Multi-step high energy ion implantation enables uniform doping to depths up to 12 µm in 4H-SiC epiwafers for superjunction devices but extent of lattice damage is of significant concern for device fabrication. 4H-SiC wafers with 12 µm thick epilayers implanted with Al ions at a concentration of 5 x 1016 cm-3 using the Tandem Van de Graaff accelerator at Brookhaven National Laboratory across an energy range of 13.8 to 65.7 MeV and at different temperatures: room temperature, 300 °C, and 600 °C were analyzed by reciprocal space mapping measurements. Implanted layers exhibited tensile strains that decreased with increasing implantation temperature indicating dynamic annealing effect reduces lattice damage. On annealing at 1700 °C, for recovery of the lattice strain, RSM measurements show that the highest implantation temperatures have the lowest residual strains. In addition, the use of a Silicon Energy-Filter for Ion Implantation (EFII) for Al implantation in a single stage to the depth of 15µm is found to further reduce lattice strain compared to wafers implanted without EFII to the same doping concentration. This preliminary study will assist in optimizing the implantation and annealing conditions for the development of superjunction devices.
- Open Access
- 23 August 2024
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 360, 151-155
Experimental Demonstration and Analysis of 3.3kV 4H-SiC Common-Drain Bidirectional Charge-Balanced Power MOSFETs
By using 4H-SiC packaged Charge-Balanced (CB) MOSFET, we have experimentally demonstrated a 3.3kV 4H-SiC common-drain bidirectional (BD) CB power MOSFET and measured its static and dynamic characteristics compared to its unidirectional counterpart. We show that the BD CB MOSFET conducts and blocks at the first and third quadrants with the appropriate gate bias with an on-state resistance double its unidirectional counterpart, while its switching energies are 12 (19) and 34 (12) mJ/cm2for BD CB MOSFET (UD CB MOSFET).
- 23 August 2024
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 360, 151-155
Open AccessExperimental Demonstration and Analysis of 3.3kV 4H-SiC Common-Drain Bidirectional Charge-Balanced Power MOSFETs
By using 4H-SiC packaged Charge-Balanced (CB) MOSFET, we have experimentally demonstrated a 3.3kV 4H-SiC common-drain bidirectional (BD) CB power MOSFET and measured its static and dynamic characteristics compared to its unidirectional counterpart. We show that the BD CB MOSFET conducts and blocks at the first and third quadrants with the appropriate gate bias with an on-state resistance double its unidirectional counterpart, while its switching energies are 12 (19) and 34 (12) mJ/cm2for BD CB MOSFET (UD CB MOSFET).
- Open Access
- 22 August 2024
- Published by Trans Tech Publications, Ltd. in Defect and Diffusion Forum
- Vol. 434, 87-92
Analysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions at Elevated Temperatures
4H-SiC wafers with 12 µm epilayers were blanket implanted to a depth of 12 µm with 5 x 1016 cm-3 Al ions via Tandem Van de Graaff accelerator located at Brookhaven National Laboratory with energy range of 13.8 to 65.7 MeV at room temperature, 300 °C and 600 °C. High resolution X-ray diffraction measurements reveal the implanted layers are characterized by tensile strains. However, the dynamic annealing process reduces the level of tensile strains as the temperature of implantation is increased. Analysis indicates that the implant temperature of 600 °C is not sufficient to minimize lattice damage due to implantation and a higher implantation temperature will be required. This preliminary experiment will guide the optimization of implantation conditions for fabricating superjunction devices.
- 22 August 2024
- Published by Trans Tech Publications, Ltd. in Defect and Diffusion Forum
- Vol. 434, 87-92
Open AccessAnalysis of Lattice Damage in 4H-SiC Epiwafers Implanted with High Energy Al Ions at Elevated Temperatures
4H-SiC wafers with 12 µm epilayers were blanket implanted to a depth of 12 µm with 5 x 1016 cm-3 Al ions via Tandem Van de Graaff accelerator located at Brookhaven National Laboratory with energy range of 13.8 to 65.7 MeV at room temperature, 300 °C and 600 °C. High resolution X-ray diffraction measurements reveal the implanted layers are characterized by tensile strains. However, the dynamic annealing process reduces the level of tensile strains as the temperature of implantation is increased. Analysis indicates that the implant temperature of 600 °C is not sufficient to minimize lattice damage due to implantation and a higher implantation temperature will be required. This preliminary experiment will guide the optimization of implantation conditions for fabricating superjunction devices.