Latest Publications

  • Open Access

    Extension to 230 kA with uncertainty reduction for calibration of shortcircuit currents at INRiM

    by Flavio Galliana, Stefano Emilio Caria, Paolo Emilio Roccato

    The Istituto Nazionale di Ricerca Metrologica (INRiM) is the only National Metrology Institute (NMI) holding the Calibration Measurement Capability (CMC) for calibrating short-circuit currents up to 170 kA under the framework of the Mutual Recognition Arrangement of the Comité international des poids et mesures (CIPM MRA). This paper presents the extension of this CMC up to 230 kA and the improvement of the measurement uncertainty of the INRiM system for calibrating sensors and measurement systems for high short-circuit currents and for the Joule integral. The extension has been possible by means of a linearity verification of the INRiM system carried out by comparing it with an intrinsically linear measurement system based on a Rogowski coil. This comparison allowed the update and refinement of the uncertainty budget, specifically the component associated with the linearity of the INRiM system, for both the peak current and the Joule integral. An innovative approach has been adopted by applying a median filter to the voltage measurement of the Rogowski coil to remove noise. This filter has been integrated into the calibration software for high short-circuit currents and optimized for the use with Rogowski coils without an integrator.The uncertainties of the INRiM measurement system have been then reviewed and improved for currents up to 170 kA and 230 kA, resulting, in relative parts 4.2×10⁻³ and 5.6×10⁻³, respectively. Consequently, the extension of the INRiM CMC for calibration of short-circuit currents and for Joule integral up to 230 kA can be considered feasible with the achieved uncertainties.


  • Open Access

    Improvement of the INRiM Calibration Capabilities for Lightning Impulse Voltages From 200 to 600 kV

    by Stefano Emilio Caria, Flavio Galliana, Paolo Emilio Roccato

    In this paper, an improvement of the calibration measurement capabilities (CMCs) of the Istituto Nazionale di Ricerca Metrologica (INRiM) for measurements of Lightning impulse (LI) voltages from 200 kV to 600 kV, is proposed. This improvement is the result of a more detailed characterization of the INRiM measurement system for LI measurements. The INRiM LI measurements of the most critical waveforms at voltages up to 600 kV for the EURAMET.EM-S42 comparison were submitted to a refinement with a discrete deconvolution method. The comparison results were then recalculated by inserting the INRiM measurements, both with and without deconvolution, (the latter for less critical waveforms) and the updated uncertainties. The INRiM measurements after recalculation were still in agreement with the comparison reference value, even for short impulses (0.84 μs), where the size of the used divider was not optimal. The recalculation did not affect the degrees of equivalence of the other participants and the consistency of the comparison. The new INRiM uncertainties range from 0.5 % of Ut (test voltage) for the long impulse at 600 kV to 2 % of T1 (front time of the impulse) for the short impulse at 400 kV and 600 kV. A validation of both the new uncertainties and the selected discrete application of deconvolution is also proposed, together with a verification of the compliance of the INRIM measurement system up to 600 kV with the requirements of a reference system.

  • Characterization of Digitizers for Combined and Composite Waveform

    by Stefano Emilio Caria, Ahmet Merev, Paolo Emilio Roccato, Serkan Dedeoglu

    Driven by the increasing demands on traceable measurement systems and given the importance of having reliable electricity grids able to support renewable energy sources and the growing energy demand for electric mobility, there is an imperative need for an adequate grid components testing. The typical tests on high voltage electricity grid systems include the combined and composite voltage tests, during which lightning or switching impulses are superimposed on the High Voltage Alternating Current or High Voltage Direct Current. However, at present, there are inadequate traceable measurement systems that can be directly connected to the equipment under combined and composite high voltage tests, which may result in unreliable test results. Combined and composite waveform measurements are complex due to their characteristics. The aspect addressed in this paper is to verify the capabilities of the recording instruments used for measurements. Nowadays, there are a lot of off-the-shelf digitizers with adequate accuracy and uncertainties for the measurement of impulse voltage and current. In high voltage testing and calibration, these digitizers are used not only in the measurement of impulse voltage but also composite and combined voltages. The current IEC 60060 standard series do not provide evidence for the ability of such measurement systems to accurately measure combined and composite voltages. Furthermore, there is a lack of standardization in the IEC 61083 series for measuring instruments and software used for combined and composite wave shapes measurements. This paper includes the characterization results of commercial digitizers which are the brands of Dr. Strauss TR-AS 200/12 and National Instruments oscilloscope PXI-5124 on DC and lightning impulse (LI) performed by INRiM and TUBITAK. This paper arises in the context of the European project 19NRM07 Hv-com 2 which support the standardization in high voltage testing.

  • Open Access

    The Effect of Thermal Stresses on the Electrical Resistance of Crimped Connections

    by F. Galliana, L. Bellavia, S. E. Caria, A. P. Perta, P. E. Roccato

    Cables headed with crimped lugs are frequently used in test laboratories in temperature rise tests carried out to validate electrical devices. The increase in the electrical resistance of the crimped connections can cause high dissipation of power and heat during these tests, impairing their outcome. This work evaluates the effect of thermal stresses on the resistance and on the dissipated power of crimped connections. This resistance was found to be more sensitive to thermal stresses than to mechanical ones analysed in a previous work. A limit of the dissipated power from crimped connections during temperature rise tests was estimated to be about 4 W corresponding to a crimp resistance of 24 μΩ for tests made at 400 A. Respecting these limits could avoid unnecessary rejections of equipment under test.


  • Open Access

    Towards a traceable divider for composite voltage waveforms below 1 kV

    by F. Galliana, S. E. Caria, P. E. Roccato

    In the framework of the European Project 19NRM07 HV-com2 supporting the standardization in high-voltage testing with composite and combined wave shapes, a divider to employ in a test set-up for validation of electrical devices submitted to composite voltages below 1 kV has been developed at the Istituto Nazionale di Ricerca Metrologica (INRIM) and currently is under extensive testing. After a simulation stage, an available divider has been modified to comply with the IEC 60,060 requirements in terms of step response and scale factor. To be suitably fast in replying to step voltages, an adjustment of the components of the low-voltage arm has been made. The divider has been calibrated with traceability to the relevant INRIM National Standards and characterized exploiting its scale factor at different voltages and frequencies. The divider has been then inserted in a set-up with a sinusoidal generator, an impulse generator and coupling–blocking elements to carry out tests at low voltages (below 1 kV) with single voltages. In these tests, the divider showed a satisfactory attitude as converting device and its scale factor is traceable with suitable uncertainty.