HMHongmei Mi

Hongmei Mi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hongmei Mi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quad‐Band Terahertz Electromagnetically Induced Transparency‐Like Metasurface Sensor With Geometry‐Constrained Inversion

    by Binggang Xiao, Luqi Liu, Wangyang Qiu, Jiabin Yu, Lihua Xiao, Hongmei Mi

    This study proposes a quad‐band terahertz electromagnetically induced transparency (EIT)‐like metasurface sensor with geometry‐constrained parameter inversion. The device consists of three concentric ring resonators and a bottom U‐shaped resonator. A gap in the inner ring breaks symmetry, while cooperative bright–dark and dark–dark mode coupling produces four transparency windows at 0.49, 0.59, 0.76, and 0.86 THz. Refractive‐index sensing simulations yield a maximum sensitivity of 269.8 GHz/RIU (RIU, refractive index unit) and a maximum Q factor of 66.4. Further experiments with antibiotic samples are required to validate practical detection performance. An improved multiscale temporal convolutional network (Improved‐TCN) captures multiscale local features and cross‐band correlations in the multimode‐coupled spectra. By integrating multiscale dilated convolutions and self‐attention, it predicts a geometrically feasible candidate set of five parameters from 201‐point linear transmission amplitude spectra. Across five independent runs, the full model achieves a standardized mean squared error (MSE) of 0.028 ± 0.001 and a coefficient of determination (R 2 ) of 0.969 ± 0.003, demonstrating stable performance on the held‐out test set. The method provides a practical reference for rapid, geometrically feasible parameter inversion of multiband terahertz sensors with predefined topologies.

  • Open Access

    Weakly supervised deep learning for multimodal MRI-TRUS registration: Toward assisting prostate biopsy guidance

    by Jiabin Yu, Binggang Xiao, Jiayi Wang, Hongmei Mi, Enyu Wang, Ningjie Huang, You Zhou, Dongping Zhang, Furong Luo, Li Yang, et al.

    Objective: Accurate magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) registration is essential for improving prostate cancer detection and biopsy guidance. This study presents a weakly supervised learning framework to enhance image alignment while minimizing reliance on extensive labeled data. Methods: We developed a two-stage weakly supervised framework integrating an attention-enhanced U-Net for prostate segmentation and a residual-enhanced registration network (RERN) for MRI-TRUS alignment. The segmentation model was trained and evaluated on public MRI datasets (MSD Prostate, Promise12, µ-RegPro) and TRUS datasets (µ-RegPro), with additional testing on a clinical cohort of 32 MRI-TRUS pairs. Performance was assessed using dice similarity coefficient (DSC), accuracy (Acc), precision (Pre), recall (Rec), and the 95th percentile Hausdorff distance (HD95). The registration model was trained and tested using MRI-TRUS pairs from µ-RegPro and the clinical cohort, with performance evaluated based on HD95 and target registration error (TRE). Additionally, clinical validation included PI-RADS-like grading, Likert confidence scoring, and receiver operating characteristic (ROC) analysis to assess diagnostic impact. Results: The segmentation model demonstrated high accuracy (DSC: MRI 0.9154, TRUS 0.9384) and strong generalizability to clinical data (MRI 0.9010, TRUS 0.9173). The registration model achieved robust performance, with HD95 of 10.18 mm on public datasets and 11.18 mm on clinical data, and TRE below 8.64 mm. Clinical validation confirmed that registered MRI images preserved diagnostic integrity, as no significant differences were observed in radiologists’ diagnostic performance (AUC: junior 0.706, senior 0.781, p > 0.05). Moreover, registered images enhanced diagnostic confidence among senior radiologists (Likert score: 3.032 vs. 3.548, p = 0.015), highlighting their potential to support expert-level decision-making. Conclusions: The proposed weakly supervised framework achieves high-precision MRI-TRUS registration with minimal annotation, ensuring strong generalizability and clinical applicability.


  • Pseudo–Contrast-enhanced US via Enhanced Generative Adversarial Networks for Evaluating Tumor Ablation Efficacy

    by Chen Chen, Jiabin Yu, Zhikang Xu, Changsong Xu, Zubang Zhou, Jindong Hao, Vicky Yang Wang, Jincao Yao, Lingyan Zhou, Chenke Xu, et al.

    The pseudo–contrast-enhanced US (CEUS) method, based on enhanced generative adversarial networks, demonstrated high similarity to real CEUS in evaluating tumor ablation effectiveness.


  • Predicting lung tumor evolution during radiotherapy from PET images using a patient specific model

    by Hongmei Mi, Caroline Petitjean, Su Ruan, Pierre Vera, Bernard Dubray

    We propose a patient-specific model based on PDE to predict the evolution of lung tumors during radiotherapy. The evolution of tumor cell densities is formulated by three terms: 1) advection describing the mobility, 2) reaction representing the proliferation modeled as Gompertz differential equation, and 3) treatment quanti tying the radiotherapeutic efficacy modeled as exponential function. As tumor cell density variation can be derived from PET images, the novel idea is to model the advection term by calculating 3D optical flow field from sequential images. To estimate patient-specific parameters, we carry out an optimization between the predicted and observed images, under a volume-dose model constraint. Threshold method is then used to define tumor contours and maximum standardized uptake values, based on the predicted tumor cell densities. We present the results obtained in 8 patients, where the predicted tumor contours are compared to those drawn by an expert.