Joshua Ireland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joshua Ireland has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
James Marco
2 shared publications- Ryan J. Mᶜglen
Aavid, Thermal Division of Boyd Corporation, Ashington NE63 8QW, UK
2 shared publications - Dinh Quang Truong
Warwick Manufacturing Group (WMG), University of Warwick, Coventry CV4 7AL, UK
1 shared publication - James Marco
The Faraday Institution, Harwell Campus Didcot UK
1 shared publication Kevin Lynn
1 shared publication- Kevin Lynn
Boyd Corporation, Unit 12, Wansbeck Business Park, Ashington NE638QW, UK
1 shared publication
Latest Publications
- Open Access
- 21 August 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 657
Effect of cylindrical cell tab architecture on global external temperature distribution using optical fibre temperature measurement
- 21 August 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 657
Open AccessEffect of cylindrical cell tab architecture on global external temperature distribution using optical fibre temperature measurement
- Open Access
An Investigation into the Insertion of a Solid Mandrel into a Commercial Cylindrical Li-Ion Cell for Improved Thermal Performance
Cylindrical Li-ion cells have found utilisation in numerous industries, but they are susceptible to thermal issues, and so they require suitable thermal management. One of the conceptual methods for addressing this issue is the introduction of a metallic mandrel inserted axially through the cell’s central cavity, which has previously been shown to have a thermal benefit through simulation, thermal emulation, and experimentally through bespoke functional test cells. This work has demonstrated the potential ability to modify a commercial LGM50 21700 cell to accept a 2 mm solid metal mandrel whilst maintaining functionality, and then to quantify the thermal behaviour under representative real-world operating conditions. The modification to external geometry is believed to have reduced the effective cooling area, and therefore leads to a temperature increase of 1–5.2 °C on the mandrel cell. The pristine reference cell then underwent the same external geometry modification, which showed no consistent thermal benefit compared to the mandrel cell, which was then validated through simulation. The simulated model evaluated the additional thermal resistances introduced by the modification process and highlighted the potential benefits of using a bespoke cell housing with an integrated mandrel over mandrel insertion. This was more significant under higher current loads, with a 7.2 °C maximum temperature reduction for the bespoke cell housing during a 3 C discharge.
Open AccessAn Investigation into the Insertion of a Solid Mandrel into a Commercial Cylindrical Li-Ion Cell for Improved Thermal Performance
Cylindrical Li-ion cells have found utilisation in numerous industries, but they are susceptible to thermal issues, and so they require suitable thermal management. One of the conceptual methods for addressing this issue is the introduction of a metallic mandrel inserted axially through the cell’s central cavity, which has previously been shown to have a thermal benefit through simulation, thermal emulation, and experimentally through bespoke functional test cells. This work has demonstrated the potential ability to modify a commercial LGM50 21700 cell to accept a 2 mm solid metal mandrel whilst maintaining functionality, and then to quantify the thermal behaviour under representative real-world operating conditions. The modification to external geometry is believed to have reduced the effective cooling area, and therefore leads to a temperature increase of 1–5.2 °C on the mandrel cell. The pristine reference cell then underwent the same external geometry modification, which showed no consistent thermal benefit compared to the mandrel cell, which was then validated through simulation. The simulated model evaluated the additional thermal resistances introduced by the modification process and highlighted the potential benefits of using a bespoke cell housing with an integrated mandrel over mandrel insertion. This was more significant under higher current loads, with a 7.2 °C maximum temperature reduction for the bespoke cell housing during a 3 C discharge.
- 7 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The effect of increasing the thermal conductivity of a cylindrical cell housing on thermal performance
The development and utilization of larger format cylindrical cells has become more prevalent in industry with a key consideration being thermal management. This paper aims to identify the effect of increasing the thermal conductivity of the cell housing on the heat rejection and thermal performance of a 4680 cell under both side and base cooling schemes with significant reduction in both maximum temperature and thermal gradients seen. It is also shown that by using the modified housing with thermal conductivity k=250 W/mK, cold plate size may be reduced by over 50% whilst maintaining the thermal performance of the standard cell.
- 7 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The effect of increasing the thermal conductivity of a cylindrical cell housing on thermal performance
The development and utilization of larger format cylindrical cells has become more prevalent in industry with a key consideration being thermal management. This paper aims to identify the effect of increasing the thermal conductivity of the cell housing on the heat rejection and thermal performance of a 4680 cell under both side and base cooling schemes with significant reduction in both maximum temperature and thermal gradients seen. It is also shown that by using the modified housing with thermal conductivity k=250 W/mK, cold plate size may be reduced by over 50% whilst maintaining the thermal performance of the standard cell.