Fabio Andretti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fabio Andretti has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Silvia Rojas-Rueda
School of Dental Medicine, Ponce Health Sciences University, Ponce 00716, Puerto Rico
6 shared publications - Carlos Alberto Jurado
School of Dental Medicine, Ponce Health Sciences University, Ponce 00716, Puerto Rico
5 shared publications - Abdulrahman Alshabib
Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
3 shared publications - Mark Adam Antal
Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, 6720 Szeged, Hungary
3 shared publications - Alfredo I. Hernandez
Prosthodontics Department, Arizona School of Dentistry and Oral Health, A.T. Still University, Mesa, AZ 85206, USA
2 shared publications - Brian Ray Morrow
Department of Bioscience Research, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN 38163, USA
2 shared publications
Latest Publications
- Open Access
Comparative Evaluation of Hydrofluoric Acid Etchants on a 3D-Printed Lithium Disilicate-Filled Polymer Resin
Background: This in vitro study compared the effects of four commercial hydrofluoric acid etchants with different nominal concentrations on the surface roughness of a 3D-printed lithium disilicate-filled polymer resin, evaluated after post-polymerization without debinding or sintering. Methods: Seventy-five specimens were randomly assigned to five groups (n = 15): G1, 4.5% hydrofluoric acid (IPS Ceramic Etching Gel, Ivoclar); G2, 4% hydrofluoric acid (Porcelain Etchant, Bisco); G3, 9.5% hydrofluoric acid (Porcelain Etchant, Bisco); G4, 9% hydrofluoric acid (Porcelain Etch, Ultradent); and G5, an unetched control. Etchants were applied for 20 s. Areal surface roughness (Sa) was measured using non-contact optical profilometry. Data were analyzed using Levene’s test, conventional and Welch’s analyses of variance, and Games–Howell pairwise comparisons (α = 0.05). Results: Both analyses of variance identified significant differences among groups (p < 0.001). All pairwise comparisons were statistically significant (p < 0.001). Mean Sa values were 0.1558 ± 0.0159 µm for G5, 0.3159 ± 0.0313 µm for G1, 0.5093 ± 0.0467 µm for G2, 0.7243 ± 0.0409 µm for G3, and 0.9365 ± 0.0408 µm for G4. The 9% Ultradent etchant produced the greatest roughness, approximately six times the control value. Conclusions: All etchants significantly increased surface roughness. However, the ranking did not follow nominal acid concentration, and differences in commercial formulations prevent attribution of the observed effects to concentration alone. These findings characterize surface modification of a 3D-printed lithium disilicate-filled polymer resin and should not be generalized to conventional lithium disilicate ceramics. Further studies are needed to determine whether these topographic changes improve subsequent adhesive bond strength or long-term durability.
Open AccessComparative Evaluation of Hydrofluoric Acid Etchants on a 3D-Printed Lithium Disilicate-Filled Polymer Resin
Background: This in vitro study compared the effects of four commercial hydrofluoric acid etchants with different nominal concentrations on the surface roughness of a 3D-printed lithium disilicate-filled polymer resin, evaluated after post-polymerization without debinding or sintering. Methods: Seventy-five specimens were randomly assigned to five groups (n = 15): G1, 4.5% hydrofluoric acid (IPS Ceramic Etching Gel, Ivoclar); G2, 4% hydrofluoric acid (Porcelain Etchant, Bisco); G3, 9.5% hydrofluoric acid (Porcelain Etchant, Bisco); G4, 9% hydrofluoric acid (Porcelain Etch, Ultradent); and G5, an unetched control. Etchants were applied for 20 s. Areal surface roughness (Sa) was measured using non-contact optical profilometry. Data were analyzed using Levene’s test, conventional and Welch’s analyses of variance, and Games–Howell pairwise comparisons (α = 0.05). Results: Both analyses of variance identified significant differences among groups (p < 0.001). All pairwise comparisons were statistically significant (p < 0.001). Mean Sa values were 0.1558 ± 0.0159 µm for G5, 0.3159 ± 0.0313 µm for G1, 0.5093 ± 0.0467 µm for G2, 0.7243 ± 0.0409 µm for G3, and 0.9365 ± 0.0408 µm for G4. The 9% Ultradent etchant produced the greatest roughness, approximately six times the control value. Conclusions: All etchants significantly increased surface roughness. However, the ranking did not follow nominal acid concentration, and differences in commercial formulations prevent attribution of the observed effects to concentration alone. These findings characterize surface modification of a 3D-printed lithium disilicate-filled polymer resin and should not be generalized to conventional lithium disilicate ceramics. Further studies are needed to determine whether these topographic changes improve subsequent adhesive bond strength or long-term durability.
- Open Access
- 3 July 2026
- Published by Springer Nature in British Dental Journal
The role of multi-acid and traditional acid etching agents on the surface roughness of a polymer-infiltrated ceramic material
Aims This study investigated the impact of a multi-acid etching solution, ZircosE (comprising HCl, HF, HNO3, and H2SO4), on a polymer-infiltrated ceramic network (PICN) material (VITA Enamic). The study also compared its performance with two conventional etchants across three different exposure times: one minute, 30 minutes, and 60 minutes.Methods Surface roughness was quantified, and microstructural changes were observed using scanning electron microscopy (SEM).Results The multi-acid etching solution consistently produced the highest surface roughness (from 0.672 ± 0.022 μm at one minute to 0.835 ± 0.023 μm at 60 minutes). SEM confirmed a progressive increase in surface porosity and particle removal with longer exposure, suggesting potential for enhanced micromechanical retention.Conclusions The multi-acid solution effectively roughened the PICN surface, demonstrating its potential as an alternative etching method. However, prolonged exposure risks over-etching and structural compromise.
- 3 July 2026
- Published by Springer Nature in British Dental Journal
Open AccessThe role of multi-acid and traditional acid etching agents on the surface roughness of a polymer-infiltrated ceramic material
Aims This study investigated the impact of a multi-acid etching solution, ZircosE (comprising HCl, HF, HNO3, and H2SO4), on a polymer-infiltrated ceramic network (PICN) material (VITA Enamic). The study also compared its performance with two conventional etchants across three different exposure times: one minute, 30 minutes, and 60 minutes.Methods Surface roughness was quantified, and microstructural changes were observed using scanning electron microscopy (SEM).Results The multi-acid etching solution consistently produced the highest surface roughness (from 0.672 ± 0.022 μm at one minute to 0.835 ± 0.023 μm at 60 minutes). SEM confirmed a progressive increase in surface porosity and particle removal with longer exposure, suggesting potential for enhanced micromechanical retention.Conclusions The multi-acid solution effectively roughened the PICN surface, demonstrating its potential as an alternative etching method. However, prolonged exposure risks over-etching and structural compromise.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 4245703
Comparative Evaluation of Novel and Conventional Acid Etchants on the Surface Roughness of Lithium Disilicate and Zirconia Ceramics
Background: Establishing a durable bond to high‐strength dental ceramics, especially zirconia (Zir), is a clinical challenge. This is due to the material’s chemical inertness and its resistance to conventional etching methods. Zir lacks silica, making it unresponsive to traditional hydrofluoric acid (HF) treatments effective for glass ceramics like lithium disilicate (LiDi). This study assesses the efficacy of a novel multiacid etchant in modifying the surface roughness of LiDi and 5 mol% yttria‐stabilized Zir (5Y‐TZP), comparing its performance against three commercial HF‐based etchants. Methods: Four etchants were tested: Zircos‐E (EDOS [ZiE]), 9.5% porcelain etchant (Bisco [BIS]), 9% porcelain etch (Ultradent [ULT]), and IPS Ceramic Etching Gel (Ivoclar [IPS]). Each was applied for 20 s, 1 min, and 30 min to LiDi (Amber Mill) and 5Y Zir (IPS e.max ZirCAD Prime MT) specimens ( n = 10 per group). Surface roughness (Ra) was measured with a profilometer. Data were analyzed using two‐way analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) test ( α = 0.05). Results: On 5Y Zir, Zircos‐E produced significantly higher surface roughness than all other etchants, reaching 0.378 µm at 30 min ( p < 0.001), indicating a greater ability to modify the Zir surface topography under the conditions evaluated in this study. On LiDi, it also resulted in the highest roughness (0.785 µm) but with signs of excessive etching and surface degradation. In contrast, the HF‐based etchants produced more controlled and uniform roughening on LiDi, without overetching. Conclusions: The novel multiacid etchant is highly effective for treating 5Y Zir, creating a favorable microretentive surface for bonding. However, its aggressive action makes it unsuitable for LiDi, where overetching can compromise structural integrity. Selection of etching agents should be material‐specific to optimize clinical outcomes while preserving ceramic quality.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 4245703
Open AccessComparative Evaluation of Novel and Conventional Acid Etchants on the Surface Roughness of Lithium Disilicate and Zirconia Ceramics
Background: Establishing a durable bond to high‐strength dental ceramics, especially zirconia (Zir), is a clinical challenge. This is due to the material’s chemical inertness and its resistance to conventional etching methods. Zir lacks silica, making it unresponsive to traditional hydrofluoric acid (HF) treatments effective for glass ceramics like lithium disilicate (LiDi). This study assesses the efficacy of a novel multiacid etchant in modifying the surface roughness of LiDi and 5 mol% yttria‐stabilized Zir (5Y‐TZP), comparing its performance against three commercial HF‐based etchants. Methods: Four etchants were tested: Zircos‐E (EDOS [ZiE]), 9.5% porcelain etchant (Bisco [BIS]), 9% porcelain etch (Ultradent [ULT]), and IPS Ceramic Etching Gel (Ivoclar [IPS]). Each was applied for 20 s, 1 min, and 30 min to LiDi (Amber Mill) and 5Y Zir (IPS e.max ZirCAD Prime MT) specimens ( n = 10 per group). Surface roughness (Ra) was measured with a profilometer. Data were analyzed using two‐way analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) test ( α = 0.05). Results: On 5Y Zir, Zircos‐E produced significantly higher surface roughness than all other etchants, reaching 0.378 µm at 30 min ( p < 0.001), indicating a greater ability to modify the Zir surface topography under the conditions evaluated in this study. On LiDi, it also resulted in the highest roughness (0.785 µm) but with signs of excessive etching and surface degradation. In contrast, the HF‐based etchants produced more controlled and uniform roughening on LiDi, without overetching. Conclusions: The novel multiacid etchant is highly effective for treating 5Y Zir, creating a favorable microretentive surface for bonding. However, its aggressive action makes it unsuitable for LiDi, where overetching can compromise structural integrity. Selection of etching agents should be material‐specific to optimize clinical outcomes while preserving ceramic quality.
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Dentistry
- Vol. 2026 (1)
Use of Topical Oxygen Therapy to Optimize Postoperative Healing of Oral Surgical Wounds After Dental Implant Placement
Implant‐supported and implant‐borne prostheses have become a common alternative for treating total or partial edentulous patients with good long‐term results. Prompt and effective healing of surgical wounds will contribute to this purpose. The objective of this case report was to evaluate by clinical observation the healing of oral postsurgical wounds following dental implant placement with or without the use of oral gel with active oxygen (BlueM). Two patients underwent dental implant placement surgery by conventional open techniques to evaluate the healing of postsurgical wounds subjected to flaps, both with immediate loading and provisionalization. In the first one, a full‐arch surgery with four implants and bone reduction was performed. In the second, two mandibular single implants were placed in Sites 46 and 36 with immediate loading and provisionalization. The active oxygen gel product (BlueM) was placed in the tissues, only on the right side, before closing the flap and after suturing. Patients were instructed to place the product only on the right side three times a day, and no product or topical medication on the left side. Observational comparisons were made by the early wound healing index (EHI) at 7, 15, and 30 days after surgery in the complete arch and at 3, 7, 15, and 30 days in the single cases. Within the limitations of these clinical cases and based solely on clinical observations, the use of active oxygen oral gel (BlueM) may enhance the healing of surgical wounds following dental implant placement, and literature supports its antiseptic and bactericidal properties. The oral gel with active oxygen (BlueM) may represent a reliable adjunctive approach for the postoperative care of oral wounds following dental implant placement. In these clinical cases, enhanced wound healing was observed; however, further controlled clinical studies are required to substantiate these findings.
- 1 January 2026
- Published by Wiley in Case Reports in Dentistry
- Vol. 2026 (1)
Open AccessUse of Topical Oxygen Therapy to Optimize Postoperative Healing of Oral Surgical Wounds After Dental Implant Placement
Implant‐supported and implant‐borne prostheses have become a common alternative for treating total or partial edentulous patients with good long‐term results. Prompt and effective healing of surgical wounds will contribute to this purpose. The objective of this case report was to evaluate by clinical observation the healing of oral postsurgical wounds following dental implant placement with or without the use of oral gel with active oxygen (BlueM). Two patients underwent dental implant placement surgery by conventional open techniques to evaluate the healing of postsurgical wounds subjected to flaps, both with immediate loading and provisionalization. In the first one, a full‐arch surgery with four implants and bone reduction was performed. In the second, two mandibular single implants were placed in Sites 46 and 36 with immediate loading and provisionalization. The active oxygen gel product (BlueM) was placed in the tissues, only on the right side, before closing the flap and after suturing. Patients were instructed to place the product only on the right side three times a day, and no product or topical medication on the left side. Observational comparisons were made by the early wound healing index (EHI) at 7, 15, and 30 days after surgery in the complete arch and at 3, 7, 15, and 30 days in the single cases. Within the limitations of these clinical cases and based solely on clinical observations, the use of active oxygen oral gel (BlueM) may enhance the healing of surgical wounds following dental implant placement, and literature supports its antiseptic and bactericidal properties. The oral gel with active oxygen (BlueM) may represent a reliable adjunctive approach for the postoperative care of oral wounds following dental implant placement. In these clinical cases, enhanced wound healing was observed; however, further controlled clinical studies are required to substantiate these findings.
- Open Access
Soft and Hard Tissue Grafting in Immediate Implant Therapy: A Narrative Review
Background and Objectives: Immediate implant placement in the esthetic zone presents challenges in maintaining peri-implant tissues due to post-extraction remodeling. Bone grafting has been proposed to support tissue preservation and improve esthetic outcomes. This article reviews the role of grafting in clinical studies and case reports. Materials and Methods: A literature search on PubMed and Google Scholar identified studies focusing on immediate implant placement with grafting. The search strategy included articles from 2012 to 2025, in English, from peer-reviewed journals. Results: Implant survival is possible without grafting in ideal cases, but grafting is often essential in patients with thin biotypes or esthetic demands. Technique and material selection are critical. The socket shield technique shows promise in preserving buccal tissues despite its complexity. Case reports demonstrated stable soft tissues and favorable esthetic outcomes. Conclusions: Grafting should be tailored to the clinical situation. While not always necessary, it is often crucial in compromised sites to ensure long-term esthetic success. Current literature supports predictable outcomes with appropriate grafting protocols.
Open AccessSoft and Hard Tissue Grafting in Immediate Implant Therapy: A Narrative Review
Background and Objectives: Immediate implant placement in the esthetic zone presents challenges in maintaining peri-implant tissues due to post-extraction remodeling. Bone grafting has been proposed to support tissue preservation and improve esthetic outcomes. This article reviews the role of grafting in clinical studies and case reports. Materials and Methods: A literature search on PubMed and Google Scholar identified studies focusing on immediate implant placement with grafting. The search strategy included articles from 2012 to 2025, in English, from peer-reviewed journals. Results: Implant survival is possible without grafting in ideal cases, but grafting is often essential in patients with thin biotypes or esthetic demands. Technique and material selection are critical. The socket shield technique shows promise in preserving buccal tissues despite its complexity. Case reports demonstrated stable soft tissues and favorable esthetic outcomes. Conclusions: Grafting should be tailored to the clinical situation. While not always necessary, it is often crucial in compromised sites to ensure long-term esthetic success. Current literature supports predictable outcomes with appropriate grafting protocols.
- 11 September 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (5) , 440-442
Enhancing dental education through virtual reality and haptic technologies
- 11 September 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (5) , 440-442
Enhancing dental education through virtual reality and haptic technologies
- Open Access
- 4 August 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (8) , 508
Surface Assessment of a Novel Acid-Etching Solution on CAD/CAM Dental Ceramics
Background: This study investigated a new multi-acid-etching formulation for zirconia ceramics, containing hydrochloric, hydrofluoric, nitric, orthophosphoric, and sulfuric acids. The solution was tested on polycrystalline (5Y-TZP zirconia), lithium disilicate, hybrid ceramic, and feldspathic porcelain to assess compatibility, etching selectivity, and surface conditioning. Methods: Two-hundred-and-forty CAD/CAM specimens were etched for 20 s, 60 s, 30 min, or 1 h, and their surface roughness and etching patterns ware evaluated using 3D optical profilometry and scanning electron microscopy (SEM). Results: A positive correlation was observed between etching time and surface roughness (Ra values). The most pronounced changes were observed in lithium disilicate and feldspathic porcelain, with Ra values increasing from 0.733 ± 0.082 µm (Group 5) to 1.295 ± 0.123 µm (Group 8), and from 0.902 ± 0.102 µm (Group 13) to 1.480 ± 0.096 µm (Group 16), respectively. Zirconia increased from 0.181 ± 0.043 µm (Group 1) to 0.371 ± 0.074 µm (Group 4), and the hybrid ceramic from 0.053 ± 0.008 µm (Group 9) to 0.099 ± 0.016 µm (Group 12). Two-way ANOVA revealed significant effects of material and etching time, as well as a significant interaction between the two factors (p < 0.001). SEM observation revealed non-selective etching pattern for the lithium disilicate groups, indicating a risk of over-etching. Conclusions: The tested etching solution increased surface roughness, especially for the lithium disilicate and feldspathic porcelain specimens. In zirconia, one-hour etching improved surface characteristics with minimal observable damage. However, additional studies are necessary to validate the mechanical stability and bond effectives of this approach.
- 4 August 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (8) , 508
Open AccessSurface Assessment of a Novel Acid-Etching Solution on CAD/CAM Dental Ceramics
Background: This study investigated a new multi-acid-etching formulation for zirconia ceramics, containing hydrochloric, hydrofluoric, nitric, orthophosphoric, and sulfuric acids. The solution was tested on polycrystalline (5Y-TZP zirconia), lithium disilicate, hybrid ceramic, and feldspathic porcelain to assess compatibility, etching selectivity, and surface conditioning. Methods: Two-hundred-and-forty CAD/CAM specimens were etched for 20 s, 60 s, 30 min, or 1 h, and their surface roughness and etching patterns ware evaluated using 3D optical profilometry and scanning electron microscopy (SEM). Results: A positive correlation was observed between etching time and surface roughness (Ra values). The most pronounced changes were observed in lithium disilicate and feldspathic porcelain, with Ra values increasing from 0.733 ± 0.082 µm (Group 5) to 1.295 ± 0.123 µm (Group 8), and from 0.902 ± 0.102 µm (Group 13) to 1.480 ± 0.096 µm (Group 16), respectively. Zirconia increased from 0.181 ± 0.043 µm (Group 1) to 0.371 ± 0.074 µm (Group 4), and the hybrid ceramic from 0.053 ± 0.008 µm (Group 9) to 0.099 ± 0.016 µm (Group 12). Two-way ANOVA revealed significant effects of material and etching time, as well as a significant interaction between the two factors (p < 0.001). SEM observation revealed non-selective etching pattern for the lithium disilicate groups, indicating a risk of over-etching. Conclusions: The tested etching solution increased surface roughness, especially for the lithium disilicate and feldspathic porcelain specimens. In zirconia, one-hour etching improved surface characteristics with minimal observable damage. However, additional studies are necessary to validate the mechanical stability and bond effectives of this approach.
- Open Access
Surface Evaluation of a Novel Acid-Etching Solution for Zirconia and Lithium Disilicate
The current investigation evaluated a novel acid-etching solution containing hydrochloric acid (HCl), hydrofluoric acid (HF), nitric acid (HNO3), orthophosphoric acid (H3PO4), and sulfuric acid (H2SO4) designed for etching zirconia ceramics. Achieving reliable bonding to zirconia is challenging due to its chemical inertia, unlike lithium disilicate, which can be effectively conditioned with HF etching. One hundred and twenty specimens of zirconia and lithium disilicate underwent etching with the experimental solution for six different durations: control, 20 s, 60 s, 5 min, 30 min, and 1 h. Surface roughness was assessed using 3D optical profilometry and scanning electron microscopy (SEM). The roughness of both materials increased with etching time; however, lithium disilicate demonstrated a significantly greater response, with Ra values rising from 0.18 µm (control) to 1.26 µm (1 h), while zirconia increased from 0.21 µm to 0.60 µm. ANOVA revealed significant effects depending on the ceramic type, time, and their interaction (p < 0.001). SEM images revealed non-selective etching of lithium disilicate, suggesting potential over-etching. The novel acid-etching solution improved surface roughness, especially in lithium disilicate ceramics. An application duration of one hour appears optimal for zirconia, improving surface characteristics while reducing damage; however, further research is required to assess its clinical safety and long-term effects on the mechanical properties of this dental ceramic.
Open AccessSurface Evaluation of a Novel Acid-Etching Solution for Zirconia and Lithium Disilicate
The current investigation evaluated a novel acid-etching solution containing hydrochloric acid (HCl), hydrofluoric acid (HF), nitric acid (HNO3), orthophosphoric acid (H3PO4), and sulfuric acid (H2SO4) designed for etching zirconia ceramics. Achieving reliable bonding to zirconia is challenging due to its chemical inertia, unlike lithium disilicate, which can be effectively conditioned with HF etching. One hundred and twenty specimens of zirconia and lithium disilicate underwent etching with the experimental solution for six different durations: control, 20 s, 60 s, 5 min, 30 min, and 1 h. Surface roughness was assessed using 3D optical profilometry and scanning electron microscopy (SEM). The roughness of both materials increased with etching time; however, lithium disilicate demonstrated a significantly greater response, with Ra values rising from 0.18 µm (control) to 1.26 µm (1 h), while zirconia increased from 0.21 µm to 0.60 µm. ANOVA revealed significant effects depending on the ceramic type, time, and their interaction (p < 0.001). SEM images revealed non-selective etching of lithium disilicate, suggesting potential over-etching. The novel acid-etching solution improved surface roughness, especially in lithium disilicate ceramics. An application duration of one hour appears optimal for zirconia, improving surface characteristics while reducing damage; however, further research is required to assess its clinical safety and long-term effects on the mechanical properties of this dental ceramic.
- Open Access
- 6 May 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (5) , 295
A Narrative Review and Clinical Study on Er:YAG Laser Debonding of Ceramic and Composite Veneers
Background: Composite resin veneers have gained popularity due to their affordability and minimally invasive application as biomimetic restorations. However, long-term clinical challenges, such as discoloration, wear, and reduced fracture resistance, necessitate their replacement over time. Ceramic veneers, particularly feldspathic and lithium disilicate, offer superior esthetics and durability, as demonstrated by studies showing their high survival rates and enamel-preserving preparation designs. However, while ceramic veneers survive longer than composite resin veneers, ceramic veneers may need to be removed and replaced. Reports vary for using Er:YAG (erbium-doped yttrium aluminum garnet) lasers for the removal of existing veneers. Methods: A review was conducted to evaluate the effectiveness of removing restorative materials with an Er:YAG laser. A clinical study was included, highlighting the conservative removal of aged composite resin veneers using the Er:YAG laser. This method minimizes enamel damage and facilitates efficient debonding. Following laser application, minimally invasive tooth preparation was performed, and feldspathic porcelain veneers were bonded. Results: The review showed positive outcomes whenever the Er:YAG laser was used. In the case study, after a 3-year follow-up, the restorations exhibited optimal function and esthetics. Conclusions: Laser-assisted debonding provides a safe and predictable method for replacing failing composite veneers with ceramic alternatives, aligning with contemporary biomimetic principles.
- 6 May 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (5) , 295
Open AccessA Narrative Review and Clinical Study on Er:YAG Laser Debonding of Ceramic and Composite Veneers
Background: Composite resin veneers have gained popularity due to their affordability and minimally invasive application as biomimetic restorations. However, long-term clinical challenges, such as discoloration, wear, and reduced fracture resistance, necessitate their replacement over time. Ceramic veneers, particularly feldspathic and lithium disilicate, offer superior esthetics and durability, as demonstrated by studies showing their high survival rates and enamel-preserving preparation designs. However, while ceramic veneers survive longer than composite resin veneers, ceramic veneers may need to be removed and replaced. Reports vary for using Er:YAG (erbium-doped yttrium aluminum garnet) lasers for the removal of existing veneers. Methods: A review was conducted to evaluate the effectiveness of removing restorative materials with an Er:YAG laser. A clinical study was included, highlighting the conservative removal of aged composite resin veneers using the Er:YAG laser. This method minimizes enamel damage and facilitates efficient debonding. Following laser application, minimally invasive tooth preparation was performed, and feldspathic porcelain veneers were bonded. Results: The review showed positive outcomes whenever the Er:YAG laser was used. In the case study, after a 3-year follow-up, the restorations exhibited optimal function and esthetics. Conclusions: Laser-assisted debonding provides a safe and predictable method for replacing failing composite veneers with ceramic alternatives, aligning with contemporary biomimetic principles.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 73
Measurement of the interface of external connection implants with metal or zirconia abutments under scanning electron microscopy
Objective Microgap at the implant–abutment interface is a critical factor that may influence both survival- and success rates of dental implants. Several studies have found that the shape of the abutment and implant, the kind of connection between the implant and abutment (external, internal, conical, and their variants), the material of the implant and abutment, tightening torque value of the screw, surface topography and preparation, and the marginal fit between components can all have an impact on the size of the microgap. Methods Eighty external hex implants (4.1 mm) from the same company were divided into four equal groups. Group 1: 4 mm diameter Anti-Rotational (AR) stock titanium abutments; Group 2: scanned (3Series, Dental Wings) and milled (RCS-1, Röders GmbH) 4 mm diameter zirconia abutments; Group 3: scanned (3Series, Dental Wings) and milled (CNC 240, Lava) 4mm diameter Zirconia abutments; and Group 4: two-piece 4.1 mm diameter stock abutments (Ti-base, CEREC, Sirona). Each implant-abutment pair was torqued according with the manufacturer’s instructions (30 Ncm, 20 Ncm, 20N cm & 35 Ncm, respectively). The samples were placed in a sample holder and segmented longitudinally. The implant-abutment microgaps was measured at 6 different pre-determined locations using optic microscopy. For each implant-abutment interface, corresponding microgaps at the right- and left sides for M1 (exterior), M2 (middle), and M3 (interior) as shown in Figure 1, were averaged and used for statistical analyses. Results A Kruskal-Wallis population equality rank test was performed on the measurements of microgaps across the four groups (1, 2, 3 and 4). The differences between the rank totals of both M1 and M3 measurements were significant; for M1: 634.00 (1), 852.00 (2), 1143.00 (3), and 611.00 (4) [H (3, n=80) = 16.97, and p-value <0.01] and for M3: 674.00 (1), 636.00 (2), 1294.00 (3), and 636.00 (4) [H (3, n=80) = 29.01, and p-value <0.01]. Specifically, it was detected that the sum of ranks were relatively larger for the external hex implants that were screwed with zirconia abutments in Group 3. Subsequently, a post-hoc pairwise comparisons using Dunn’s test shows that Group 1 microgaps were significantly different from those of Group 3 for both M1 (mean difference = -3.47 and p-value <0.01) and M3 (mean difference = -4.22 and p-value 0.01). The post-hoc sensitivity analysis using the Dunnett’s test confirms that the measurements in Group 1 (controls) were significantly different from those in Group 3 for both M1 (contrast = 38.15, Std. Error = 8.84, 95% CI 18.40–57.91, and p-value <0.01) and M3 (contrast = 63.51, Std. Error = 8.36, 95% CI 43.48–83.53, and p-value <0.01). Conclusion In this in vitro study, it was found that the Zirconia abutments showed relatively greater microgaps and hence mismatches at the implant-abutment interfaces compared to the prefabricated metal abutments.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 73
Open AccessMeasurement of the interface of external connection implants with metal or zirconia abutments under scanning electron microscopy
Objective Microgap at the implant–abutment interface is a critical factor that may influence both survival- and success rates of dental implants. Several studies have found that the shape of the abutment and implant, the kind of connection between the implant and abutment (external, internal, conical, and their variants), the material of the implant and abutment, tightening torque value of the screw, surface topography and preparation, and the marginal fit between components can all have an impact on the size of the microgap. Methods Eighty external hex implants (4.1 mm) from the same company were divided into four equal groups. Group 1: 4 mm diameter Anti-Rotational (AR) stock titanium abutments; Group 2: scanned (3Series, Dental Wings) and milled (RCS-1, Röders GmbH) 4 mm diameter zirconia abutments; Group 3: scanned (3Series, Dental Wings) and milled (CNC 240, Lava) 4mm diameter Zirconia abutments; and Group 4: two-piece 4.1 mm diameter stock abutments (Ti-base, CEREC, Sirona). Each implant-abutment pair was torqued according with the manufacturer’s instructions (30 Ncm, 20 Ncm, 20N cm & 35 Ncm, respectively). The samples were placed in a sample holder and segmented longitudinally. The implant-abutment microgaps was measured at 6 different pre-determined locations using optic microscopy. For each implant-abutment interface, corresponding microgaps at the right- and left sides for M1 (exterior), M2 (middle), and M3 (interior) as shown in Figure 1, were averaged and used for statistical analyses. Results A Kruskal-Wallis population equality rank test was performed on the measurements of microgaps across the four groups (1, 2, 3 and 4). The differences between the rank totals of both M1 and M3 measurements were significant; for M1: 634.00 (1), 852.00 (2), 1143.00 (3), and 611.00 (4) [H (3, n=80) = 16.97, and p-value <0.01] and for M3: 674.00 (1), 636.00 (2), 1294.00 (3), and 636.00 (4) [H (3, n=80) = 29.01, and p-value <0.01]. Specifically, it was detected that the sum of ranks were relatively larger for the external hex implants that were screwed with zirconia abutments in Group 3. Subsequently, a post-hoc pairwise comparisons using Dunn’s test shows that Group 1 microgaps were significantly different from those of Group 3 for both M1 (mean difference = -3.47 and p-value <0.01) and M3 (mean difference = -4.22 and p-value 0.01). The post-hoc sensitivity analysis using the Dunnett’s test confirms that the measurements in Group 1 (controls) were significantly different from those in Group 3 for both M1 (contrast = 38.15, Std. Error = 8.84, 95% CI 18.40–57.91, and p-value <0.01) and M3 (contrast = 63.51, Std. Error = 8.36, 95% CI 43.48–83.53, and p-value <0.01). Conclusion In this in vitro study, it was found that the Zirconia abutments showed relatively greater microgaps and hence mismatches at the implant-abutment interfaces compared to the prefabricated metal abutments.