YWYongjun Wu

Yongjun Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yongjun Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Bing Chen

    Department of Gastroenterology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China

    1 shared publication
  • Guan Yang

    School of Electrical and Information Engineering, National Center for International Joint Research of Electronic Materials and Systems, International Joint-Laboratory of Electronic Materials and Systems of Henan Province, Institute of Intelligence Sensing, Zhengzhou University, Zhengzhou, China

    1 shared publication
  • Jianquan Yao

    Tianjin University

    1 shared publication
  • Meize Chen

    School of Electrical and Information Engineering, National Center for International Joint Research of Electronic Materials and Systems, International Joint-Laboratory of Electronic Materials and Systems of Henan Province, Institute of Intelligence Sensing, Zhengzhou University, Zhengzhou, China

    1 shared publication
  • Pibin Bing

    College of Electrical Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China

    1 shared publication
  • Shuai Sun

    College of Engineering Physics, Shenzhen Technology University, Shenzhen, China

    1 shared publication

Latest Publications

  • Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection

    by Xianchao Yang, Guan Yang, Meize Chen, Bing Chen, Yang Gao, Shuai Sun, Pibin Bing, Yongjun Wu, Xiaonan Yang, Yuhuai Liu, et al.

    A simple Mach-Zehnder interferometer (MZI) induced by no-core-fiber (NCF) offset microcavity is proposed and demonstrated for temperature self-compensated biosensing. The microcavity is fabricated by on-line fiber cutting-welding method. Benefiting from the directly interact between microfluidics and fiber core signal in microcavity instead of evanescent wave, an ultrahigh RI sensitivity of -12146 nm/RIU was obtained by experiment with temperature cross-sensitivity of 2.05 nm/°C. The influence of microcavity length was analyzed in detail. Temperature self-compensation can be realized by solving a multivariate matrix. Finally, the bovine serum albumin (BSA) samples in different concentrations were detected to evaluate the biosensing capability. Experiments demonstrated that the designed sensor exhibited a BSA concentration sensitivity of -10.4 nm/mg/mL and a detection limit of 1.9 μg/mL, which shows great potential for label-free biochemical trace detections without temperature-induced cross-sensitivity.