Minxia Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minxia Shi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Fan Yang
Beihang University
1 shared publication - Fulong Wang
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
1 shared publication - Fuzhi Cao
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
1 shared publication Gang Liu
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
1 shared publication- Hanxing Wang
Beihang University
1 shared publication - Jianzhi Yang
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
The Regulation Method of Magnetization State for Magnetic Shielding Devices Using the MSD-R-D System Based on Ant Colony Algorithm and Local Flux Detection
Magnetic shielding devices (MSD) constitute essential infrastructure for realizing near-zero magnetic field environments and enabling high-precision quantum magnetic measurements. The performance of these devices is governed by the magnetization state of the high-permeability permalloy of the MSD. However, conventional testing and degaussing techniques are incapable of precisely detecting or regulating the local magnetization state of the MSD. To overcome this limitation, this paper proposes an MSD-R-D system that enables uniform regulation and global detection of the magnetization state of the MSD. A path-planning approach based on the ant colony algorithm is adopted to design the regulation coil, thereby generating a highly uniform excitation magnetic field. Furthermore, a B probe-type sensor integrated with a signal processing module is utilized to achieve localized measurement of the magnetic flux density on the MSD surface. Experimental results demonstrate that, after applying the MSD-R-D system, the MSD exhibits a uniform surface flux distribution, high consistency in the magnetization process, and substantially improved shielding performance, thereby validating the efficiency of the proposed system.
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Regulation Method of Magnetization State for Magnetic Shielding Devices Using the MSD-R-D System Based on Ant Colony Algorithm and Local Flux Detection
Magnetic shielding devices (MSD) constitute essential infrastructure for realizing near-zero magnetic field environments and enabling high-precision quantum magnetic measurements. The performance of these devices is governed by the magnetization state of the high-permeability permalloy of the MSD. However, conventional testing and degaussing techniques are incapable of precisely detecting or regulating the local magnetization state of the MSD. To overcome this limitation, this paper proposes an MSD-R-D system that enables uniform regulation and global detection of the magnetization state of the MSD. A path-planning approach based on the ant colony algorithm is adopted to design the regulation coil, thereby generating a highly uniform excitation magnetic field. Furthermore, a B probe-type sensor integrated with a signal processing module is utilized to achieve localized measurement of the magnetic flux density on the MSD surface. Experimental results demonstrate that, after applying the MSD-R-D system, the MSD exhibits a uniform surface flux distribution, high consistency in the magnetization process, and substantially improved shielding performance, thereby validating the efficiency of the proposed system.
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 1065-1075
Design and Optimization of Bi-Planar Coils for Active Magnetic Compensation System Inside the MINI-Magnetically Shielded Room
The MINI-magnetically shielded room (MINI-MSR) offers a near-zero magnetic environment for the high performance of optically pumped atomic magnetometers (OPMs) in magnetoencephalography (MEG) tests. It has the advantages, such as being small-sized, portable, lightweight, offering efficient space utilization, and being cost-effective. However, owing to its small size and narrow internal space, the MINI-MSR can only provide a limited uniform region with larger gradients and irregular magnetic noise distributions. Moreover, it is affected by large external background fluctuations. Once the external interference exceeds the magnetic shielding capacity of the MINI-MSR, the precision of OPMs is compromised. Therefore, an active magnetic compensation system (AMCS) composed of biplanar coils (BCs) is introduced to enlarge the uniform region, maintaining the inhomogeneity errors below 1% to meet the measurement accuracy. However, conventional algorithms for designing BCs struggle with searching for the regularization coefficient ω that determines the coil’s shape. The process lacks ergodicity and efficiency, posing challenges in obtaining maximum volume and uniformity within the target region. In this study, a new hybrid method (NHM) composed of the target field method (TFM), image method (IM), and novel artificial fish swarm algorithm (novel ASFA) is proposed to design BCs for the AMCS. The aim is to suppress background field fluctuations, enhancing the signal-to-noise ratio while addressing coupled errors to reduce larger gradients and magnetic noise levels. Experimental results show that the maximum inhomogeneity error of BCs is less than 1.23%, which is consistent with simulation results. The sensitivity of the AMCS at 0.01 Hz ranges from 180 to 0.16 pT/Hz 1/2 , realizing the noise suppression ratio of 30.51 dB. Based on the closed-loop AMCS, the signal-to-noise ratio in the alpha rhythm generation task is effectively improved.
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 1065-1075
Design and Optimization of Bi-Planar Coils for Active Magnetic Compensation System Inside the MINI-Magnetically Shielded Room
The MINI-magnetically shielded room (MINI-MSR) offers a near-zero magnetic environment for the high performance of optically pumped atomic magnetometers (OPMs) in magnetoencephalography (MEG) tests. It has the advantages, such as being small-sized, portable, lightweight, offering efficient space utilization, and being cost-effective. However, owing to its small size and narrow internal space, the MINI-MSR can only provide a limited uniform region with larger gradients and irregular magnetic noise distributions. Moreover, it is affected by large external background fluctuations. Once the external interference exceeds the magnetic shielding capacity of the MINI-MSR, the precision of OPMs is compromised. Therefore, an active magnetic compensation system (AMCS) composed of biplanar coils (BCs) is introduced to enlarge the uniform region, maintaining the inhomogeneity errors below 1% to meet the measurement accuracy. However, conventional algorithms for designing BCs struggle with searching for the regularization coefficient ω that determines the coil’s shape. The process lacks ergodicity and efficiency, posing challenges in obtaining maximum volume and uniformity within the target region. In this study, a new hybrid method (NHM) composed of the target field method (TFM), image method (IM), and novel artificial fish swarm algorithm (novel ASFA) is proposed to design BCs for the AMCS. The aim is to suppress background field fluctuations, enhancing the signal-to-noise ratio while addressing coupled errors to reduce larger gradients and magnetic noise levels. Experimental results show that the maximum inhomogeneity error of BCs is less than 1.23%, which is consistent with simulation results. The sensitivity of the AMCS at 0.01 Hz ranges from 180 to 0.16 pT/Hz 1/2 , realizing the noise suppression ratio of 30.51 dB. Based on the closed-loop AMCS, the signal-to-noise ratio in the alpha rhythm generation task is effectively improved.