Hye-Jin Ju
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hye-Jin Ju has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hee-Jung Yeom
Institute of Plasma Technology, Korea Institute of Fusion Energy 5 , Gunsan 54011
2 shared publications - Hyo-Chang Lee
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
2 shared publications - Jung-Hyung Kim
Korea Research Institute of Standards and Science 1 , Daejeon 34113
2 shared publications - Chan-Won Park
Korea Research Institute of Standards and Science
1 shared publication - Do-Yeon Hwang
Semiconductor and Display Metrology Group, Korea Research Institute of Standards and Science (KRISS) 1 , Daejeon 34113
1 shared publication - Gwang-Seok Chae
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
1 shared publication
Latest Publications
- 12 May 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (5)
Analysis of electron series resonance in lowpressure plasmas using a DC-biased cutoff probe
Electron series resonance (ESR) can be interpreted as a series LC resonance between the inductive plasma and the capacitive sheaths. Depending on plasma characteristics, the ESR properties can shift with operating conditions. In prior studies, ESR was analyzed by varying external parameters such as input power, pressure, and electrode gap. However, these external parameters change not only the electron density but also other plasma parameters, such as the electron temperature. Therefore, an ESR analysis system capable of independently controlling these plasma parameters is needed. In this study, we developed an ESR analysis platform that can control the sheath thickness independently of other plasma parameters such as electron density, electron temperature, and pressure. A conventional cutoff probe consisting of the radiating and detecting antennas measures the absolute electron density. We confirmed through measured electron density and electron temperature that only the thickness of the biased sheath can be controlled by applying a DC bias voltage (V_DC) to one antenna of the cutoff probe, and observed the frequency trend of ESR frequency according to the sheath thickness. To analyze ESR characteristics according to sheath thickness, an equivalent circuit model was used. The circuit model's component values were calculated based on experimental results such as electron density, electron temperature, and discharge pressure. The observed ESR frequencies indicate an increase of the ESR frequency as |V_DC | increases, due to reduced sheath capacitance. The ESR frequency derived using the circuit model shows consistent results with the measured ESR frequency. These results enable a more detailed analysis of ESR characteristics under controlled plasma conditions and improve the accuracy of microwave cutoff–based diagnostics for determining plasma parameters, including electron temperature and electron density.
- 12 May 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (5)
Analysis of electron series resonance in lowpressure plasmas using a DC-biased cutoff probe
Electron series resonance (ESR) can be interpreted as a series LC resonance between the inductive plasma and the capacitive sheaths. Depending on plasma characteristics, the ESR properties can shift with operating conditions. In prior studies, ESR was analyzed by varying external parameters such as input power, pressure, and electrode gap. However, these external parameters change not only the electron density but also other plasma parameters, such as the electron temperature. Therefore, an ESR analysis system capable of independently controlling these plasma parameters is needed. In this study, we developed an ESR analysis platform that can control the sheath thickness independently of other plasma parameters such as electron density, electron temperature, and pressure. A conventional cutoff probe consisting of the radiating and detecting antennas measures the absolute electron density. We confirmed through measured electron density and electron temperature that only the thickness of the biased sheath can be controlled by applying a DC bias voltage (V_DC) to one antenna of the cutoff probe, and observed the frequency trend of ESR frequency according to the sheath thickness. To analyze ESR characteristics according to sheath thickness, an equivalent circuit model was used. The circuit model's component values were calculated based on experimental results such as electron density, electron temperature, and discharge pressure. The observed ESR frequencies indicate an increase of the ESR frequency as |V_DC | increases, due to reduced sheath capacitance. The ESR frequency derived using the circuit model shows consistent results with the measured ESR frequency. These results enable a more detailed analysis of ESR characteristics under controlled plasma conditions and improve the accuracy of microwave cutoff–based diagnostics for determining plasma parameters, including electron temperature and electron density.
- Open Access
- 30 March 2025
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 34 (2) , 75-79
Parametric Analysis of Substrate Heating in Low-Pressure Inductively Coupled Plasma
Jin-Hoo Seong, Hee-Jung Yeom, Min Young Yoon, Do-Yeon Hwang, Hye-Jin Ju, Wooram Kim, Hyo-Chang Lee, and Jung-Hyung Kim. Applied Science and Convergence Technology 2025;34:75-9. https://doi.org/10.5757/ASCT.2025.34.2.75
- 30 March 2025
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 34 (2) , 75-79
Open AccessParametric Analysis of Substrate Heating in Low-Pressure Inductively Coupled Plasma