Ata Babazadeh-Naseri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ata Babazadeh-Naseri has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Leardini
Movement Analysis Laboratory and Functional Evaluation of Prostheses, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
1 shared publication - Benedetta Spazzoli
Orthopaedic Oncology Unit , IRCCS Istituto Ortopedico Rizzoli , Bologna , Italy , ior.it
1 shared publication - Benjamin J. Fregly
Rice Computational Neuromechanics Lab, Department of Mechanical Engineering, Rice University, Houston, TX, United States
1 shared publication - Claudio Belvedere
Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
1 shared publication - Davide Donati
Clinica Ortopedica e Traumatologica III a Prevalente Indirizzo Oncologico, Musculoskeletal Oncology Department, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
1 shared publication - John E. Akin
Department of Mechanical Engineering, Rice University, Houston, TX, USA
1 shared publication
Latest Publications
- 9 March 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 138 (1) , 104321
Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling
Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.
- 9 March 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 138 (1) , 104321
Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling
Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.