Xintong Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xintong Mao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bailiang Liu
State Grid Jiangsu Electric Power Co., Ltd., Nanjing 210024, China
1 shared publication Bin Bo
State Grid Jiangsu Electric Power Engineering Consulting CO., Ltd., Nanjing, China
1 shared publication- Changyun Xu
East China Electric Power Design Institute Co., Ltd., China Power Engineering Consulting Group, Shanghai 200063, China
1 shared publication - Chuyang Wang
Hohai University
1 shared publication - Dongbin Lu
Tsinghua University
1 shared publication - Han Wu
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China
1 shared publication
Latest Publications
- Open Access
- 14 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2115
Commutation Failure Immunity Mechanism and State-Aware Coordinated Protection Strategy for SLCC-HVDC in Weak Receiving-End Grids
In weak receiving-end grids, the active support of the valve-side static var compensator and filter (SVF) extends the commutation failure (CF) boundary of LCC-HVDC. However, SVF control state transitions reshape valve-side voltage and harmonic characteristics, causing conventional fixed threshold protection to exhibit concurrent misblocking and failure to operate risks, while SVF zone internal faults are prone to excessive pole-level escalation. This paper proposes a state-aware coordinated protection strategy for symmetric single-pole SLCC-HVDC systems. A normalized commutation margin index, derived from the commutation voltage time integral, characterizes the nonlinear CF boundary under SVF support. SVF control mode, health status, and reactive power margin serve as conditioning variables for adaptive threshold and time window modification. A three-level escalation strategy—local isolation, derated ride-through, and pole-level action—is further designed for SVF zone faults. Validation via RTDS sequence of events records and EMT–protection logic replay co-simulation shows that the proposed index achieves a 100% CF risk prediction rate across five fault scenarios, versus 40% for conventional indices. The method maintains zero failure to operate with a misblocking rate ≤ 10.1% at SNR ≥ 30 dB. The staged response correctly escalates all four SVF zone fault types to the required level, compared with two of four for the fixed threshold baseline. These results confirm effective enhancement of protection robustness, fault ride-through capability, and operational continuity for SLCC-HVDC in weak receiving-end grids.
- 14 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2115
Open AccessCommutation Failure Immunity Mechanism and State-Aware Coordinated Protection Strategy for SLCC-HVDC in Weak Receiving-End Grids
In weak receiving-end grids, the active support of the valve-side static var compensator and filter (SVF) extends the commutation failure (CF) boundary of LCC-HVDC. However, SVF control state transitions reshape valve-side voltage and harmonic characteristics, causing conventional fixed threshold protection to exhibit concurrent misblocking and failure to operate risks, while SVF zone internal faults are prone to excessive pole-level escalation. This paper proposes a state-aware coordinated protection strategy for symmetric single-pole SLCC-HVDC systems. A normalized commutation margin index, derived from the commutation voltage time integral, characterizes the nonlinear CF boundary under SVF support. SVF control mode, health status, and reactive power margin serve as conditioning variables for adaptive threshold and time window modification. A three-level escalation strategy—local isolation, derated ride-through, and pole-level action—is further designed for SVF zone faults. Validation via RTDS sequence of events records and EMT–protection logic replay co-simulation shows that the proposed index achieves a 100% CF risk prediction rate across five fault scenarios, versus 40% for conventional indices. The method maintains zero failure to operate with a misblocking rate ≤ 10.1% at SNR ≥ 30 dB. The staged response correctly escalates all four SVF zone fault types to the required level, compared with two of four for the fixed threshold baseline. These results confirm effective enhancement of protection robustness, fault ride-through capability, and operational continuity for SLCC-HVDC in weak receiving-end grids.
- Open Access
An Abnormal Increase in Switching Frequency in Multi-Sources Line Commutated Converter and Suppression Method
Distinct from the traditional Modular Multilevel Converter (MMC) which focuses on fundamental frequency operation, the Static Var and Filter (SVF) within the Multi-Source Line-Commutated Converter (SLCC) system is tasked with the core function of high-frequency harmonic filtering. This paper reveals a unique engineering reliability issue stemming from this functional difference: to satisfy the Nyquist sampling theorem for precise tracking and elimination of high-frequency harmonics, the update frequency of the capacitor voltage balancing algorithm in the SLCC-SVF system is forced to increase significantly. Mathematical modeling and quantitative analysis demonstrate that this strong coupling between harmonic tracking demands and the voltage sorting strategy directly drives an abnormal surge in the average switching frequency (reaching over five times that of the fundamental condition), severely threatening device safety. To address this, an optimized adaptive hybrid modulation strategy is proposed. The system operates under Nearest Level Modulation (NLM) in normal conditions and automatically transitions to Carrier Phase-Shifted PWM (CPS-PWM)—leveraging its closed-loop balancing capability—when switching frequency or junction temperature exceeds safety thresholds. Furthermore, a non-integer frequency ratio optimization theory for low-modulation indices is constructed specifically for SVF conditions to prevent low-frequency oscillations. PLECS simulation results validate the theoretical analysis, showing that the proposed strategy effectively reduces the average switching frequency by approximately 20% under complex harmonic conditions, significantly enhancing thermal stability and operational reliability while guaranteeing filtering performance.
Open AccessAn Abnormal Increase in Switching Frequency in Multi-Sources Line Commutated Converter and Suppression Method
Distinct from the traditional Modular Multilevel Converter (MMC) which focuses on fundamental frequency operation, the Static Var and Filter (SVF) within the Multi-Source Line-Commutated Converter (SLCC) system is tasked with the core function of high-frequency harmonic filtering. This paper reveals a unique engineering reliability issue stemming from this functional difference: to satisfy the Nyquist sampling theorem for precise tracking and elimination of high-frequency harmonics, the update frequency of the capacitor voltage balancing algorithm in the SLCC-SVF system is forced to increase significantly. Mathematical modeling and quantitative analysis demonstrate that this strong coupling between harmonic tracking demands and the voltage sorting strategy directly drives an abnormal surge in the average switching frequency (reaching over five times that of the fundamental condition), severely threatening device safety. To address this, an optimized adaptive hybrid modulation strategy is proposed. The system operates under Nearest Level Modulation (NLM) in normal conditions and automatically transitions to Carrier Phase-Shifted PWM (CPS-PWM)—leveraging its closed-loop balancing capability—when switching frequency or junction temperature exceeds safety thresholds. Furthermore, a non-integer frequency ratio optimization theory for low-modulation indices is constructed specifically for SVF conditions to prevent low-frequency oscillations. PLECS simulation results validate the theoretical analysis, showing that the proposed strategy effectively reduces the average switching frequency by approximately 20% under complex harmonic conditions, significantly enhancing thermal stability and operational reliability while guaranteeing filtering performance.
- 4 April 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (2) , 1-9
The Effect of Buoyancy Convection and Geometric Variation on Temperature Field of C4F7N-Filled Gas-Insulated Metal Transmission Line
- 4 April 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (2) , 1-9
The Effect of Buoyancy Convection and Geometric Variation on Temperature Field of C4F7N-Filled Gas-Insulated Metal Transmission Line