Naibo Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Naibo Feng has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Longxin An
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
4 shared publicationsJie Zhao
Weifang People's Hospital, Shandong Second Medical University, Weifang 261000, China
2 shared publicationsXiaojing Li
Department of Trauma Orthopedics, Weifang People's Hospital, Shandong Second Medical University, Weifang, China
2 shared publicationsXuecheng Sun
Weifang People's Hospital, Shandong Second Medical University, Weifang 261000, China
2 shared publications- Xuecheng Sun
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
2 shared publications - Chao Zhang
Department of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e50043
A single-center retrospective observational study of modified anterolateral arthroscopic double-loop plate fixation for acute acromioclavicular joint dislocation
This study aimed to evaluate the clinical efficacy of double-loop plate fixation via the subacromial coracoid approach (modified anterolateral shoulder arthroscopy) for acute acromioclavicular joint dislocation of Rockwood Grade III or higher. A retrospective single-center observational study included 68 patients treated at Weifang People’s Hospital from October 2022 to April 2024. Outcomes included pre- and postoperative pain (Visual Analog Scale), functional recovery (Constant Score), range of motion, and radiographic reduction (coracoclavicular distance [CCD] and acromioclavicular distance [ACD]). Repeated-measures analysis of variance evaluated longitudinal changes; paired t -tests compared CCD and ACD between 2 days and 6 months postoperatively. P < .05 was considered significant. All 68 patients completed ≥ 6-month follow-up. Significant improvements were observed in Visual Analog Scale, Constant Score, and range of motion at 1, 3, and 6 months postoperatively (all P < .01), with stable CCD and ACD radiographically. The modified arthroscopic double-loop plate fixation shows short-term efficacy in acute Rockwood III–VI acromioclavicular joint dislocation, with pain relief, functional recovery, and stable radiographic reduction. Limitations include retrospective, single-center design, lack of comparator, and short-term follow-up; long-term efficacy requires prospective controlled trials.
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e50043
Open AccessA single-center retrospective observational study of modified anterolateral arthroscopic double-loop plate fixation for acute acromioclavicular joint dislocation
This study aimed to evaluate the clinical efficacy of double-loop plate fixation via the subacromial coracoid approach (modified anterolateral shoulder arthroscopy) for acute acromioclavicular joint dislocation of Rockwood Grade III or higher. A retrospective single-center observational study included 68 patients treated at Weifang People’s Hospital from October 2022 to April 2024. Outcomes included pre- and postoperative pain (Visual Analog Scale), functional recovery (Constant Score), range of motion, and radiographic reduction (coracoclavicular distance [CCD] and acromioclavicular distance [ACD]). Repeated-measures analysis of variance evaluated longitudinal changes; paired t -tests compared CCD and ACD between 2 days and 6 months postoperatively. P < .05 was considered significant. All 68 patients completed ≥ 6-month follow-up. Significant improvements were observed in Visual Analog Scale, Constant Score, and range of motion at 1, 3, and 6 months postoperatively (all P < .01), with stable CCD and ACD radiographically. The modified arthroscopic double-loop plate fixation shows short-term efficacy in acute Rockwood III–VI acromioclavicular joint dislocation, with pain relief, functional recovery, and stable radiographic reduction. Limitations include retrospective, single-center design, lack of comparator, and short-term follow-up; long-term efficacy requires prospective controlled trials.
- Open Access
- 9 June 2026
- Published by Wiley in Advanced Science
- Vol. 13 (48) , e75995
Targeting Dnmt3a/m5C/RelA Axis Attenuates Microglia Inflammatory Response and Improves Postoperative Recovery in Chronic Compressive Cervical Spinal Cord Injury
Chronic compressive cervical spinal cord injury (cCSCI) is a major cause of adult spinal cord dysfunction. Surgical decompression is the primary treatment; however, microglia‐driven neuroinflammation often hampers postoperative recovery. This study was conducted to investigate the role of 5‐methylcytosine (m5C) in sustaining pro‐inflammatory microglial states following decompression. Using a mouse cCSCI model, we performed single‐nucleus RNA sequencing (snRNA‐seq) to map microglial states, calculated an m5C‐regulator activity score, and validated m5C changes via dot blot. We examined the Dnmt3a–RelA pathway in primary microglia through siRNA knockdown, m5C‐RIP, and mRNA stability assays. Therapeutic potential was assessed with intrathecal AAV‐shDnmt3a. SnRNA‐seq revealed a dominant pro‐inflammatory microglial subpopulation (C1) post‐decompression, enriched for NF‐κB signaling. The C1 subset exhibited an elevated m5C score and increased Dnmt3a expression. Dnmt3a knockdown reduced m5C enrichment on RelA transcripts, destabilized RelA mRNA, and suppressed NF‐κB activation. In vitro, Dnmt3a silencing reduced pro‐inflammatory marker expression and cytokine release, and microglia‐targeted AAV‐shDnmt3a improved neurological recovery in cCSCI mice. These findings underscore the potential of targeting the microglia Dnmt3a/m5C/RelA axis to enhance postoperative recovery.
- 9 June 2026
- Published by Wiley in Advanced Science
- Vol. 13 (48) , e75995
Open AccessTargeting Dnmt3a/m5C/RelA Axis Attenuates Microglia Inflammatory Response and Improves Postoperative Recovery in Chronic Compressive Cervical Spinal Cord Injury
Chronic compressive cervical spinal cord injury (cCSCI) is a major cause of adult spinal cord dysfunction. Surgical decompression is the primary treatment; however, microglia‐driven neuroinflammation often hampers postoperative recovery. This study was conducted to investigate the role of 5‐methylcytosine (m5C) in sustaining pro‐inflammatory microglial states following decompression. Using a mouse cCSCI model, we performed single‐nucleus RNA sequencing (snRNA‐seq) to map microglial states, calculated an m5C‐regulator activity score, and validated m5C changes via dot blot. We examined the Dnmt3a–RelA pathway in primary microglia through siRNA knockdown, m5C‐RIP, and mRNA stability assays. Therapeutic potential was assessed with intrathecal AAV‐shDnmt3a. SnRNA‐seq revealed a dominant pro‐inflammatory microglial subpopulation (C1) post‐decompression, enriched for NF‐κB signaling. The C1 subset exhibited an elevated m5C score and increased Dnmt3a expression. Dnmt3a knockdown reduced m5C enrichment on RelA transcripts, destabilized RelA mRNA, and suppressed NF‐κB activation. In vitro, Dnmt3a silencing reduced pro‐inflammatory marker expression and cytokine release, and microglia‐targeted AAV‐shDnmt3a improved neurological recovery in cCSCI mice. These findings underscore the potential of targeting the microglia Dnmt3a/m5C/RelA axis to enhance postoperative recovery.
- Open Access
- 17 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0347522
Utilization of the posterior iliac line for visualizing posterior column screws in obturator oblique view
Purpose: To evaluate whether posterior column screws penetrate the posterior cortical surface of the acetabulum when assessed using obturator oblique radiographic imaging. Methods: Computed tomography (CT) scans were performed on the right acetabulum of 50 healthy adults to measure the angle (α) between the posterior wall of the acetabulum and the sagittal plane at the level of the femoral head’s maximal diameter. In addition, five cadaveric pelvises were subjected to C-arm fluoroscopic imaging. A 6 cm long, 1.5 mm Kirschner wire was positioned along the posterior surface of the acetabular posterior column, aligned with the greater sciatic notch, and imaged in both the 45° and α-degree obturator oblique views. The radiographic line visualized from the Kirschner wire in the obturator oblique view was defined as the posterior iliac line , and its anatomical relationship with the posterior surface of the posterior column was analyzed. Subsequently, a 2.5 mm Kirschner wire was inserted into the posterior column at the standard entry point for screw placement using an electric drill, with the wire tip intentionally positioned between the posterior iliac line and the posterior rim in the 45° obturator oblique view. The trajectory of the wire was assessed under both 45° and α-degree obturator oblique views to determine its relation to the osseous corridor. Results: The measured angle between the posterior surface of the acetabular posterior column and the sagittal plane was (60.2 ± 2.5)°. In the 45° obturator oblique view, the posterior iliac line corresponded with the outer edge of the iliac crest superiorly and the outer edge of the ischium inferiorly, while the posterior wall was projected posterior to the midpoint of the posterior iliac line. In the α° obturator oblique view, the posterior iliac line maintained this alignment but intersected centrally with the posterior acetabular wall. The 2.5 mm Kirschner wire remained within the osseous corridor under the 45° view but potentially extended beyond it under the α° view. Conclusion: When the posterior column screw is visualized posterior to the posterior iliac line in the 45° obturator oblique view, further assessment using a α° view is necessary. If the screw appears anterior to the posterior iliac line in the α° view, it indicates that the posterior cortical surface has not been breached.
- 17 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0347522
Open AccessUtilization of the posterior iliac line for visualizing posterior column screws in obturator oblique view
Purpose: To evaluate whether posterior column screws penetrate the posterior cortical surface of the acetabulum when assessed using obturator oblique radiographic imaging. Methods: Computed tomography (CT) scans were performed on the right acetabulum of 50 healthy adults to measure the angle (α) between the posterior wall of the acetabulum and the sagittal plane at the level of the femoral head’s maximal diameter. In addition, five cadaveric pelvises were subjected to C-arm fluoroscopic imaging. A 6 cm long, 1.5 mm Kirschner wire was positioned along the posterior surface of the acetabular posterior column, aligned with the greater sciatic notch, and imaged in both the 45° and α-degree obturator oblique views. The radiographic line visualized from the Kirschner wire in the obturator oblique view was defined as the posterior iliac line , and its anatomical relationship with the posterior surface of the posterior column was analyzed. Subsequently, a 2.5 mm Kirschner wire was inserted into the posterior column at the standard entry point for screw placement using an electric drill, with the wire tip intentionally positioned between the posterior iliac line and the posterior rim in the 45° obturator oblique view. The trajectory of the wire was assessed under both 45° and α-degree obturator oblique views to determine its relation to the osseous corridor. Results: The measured angle between the posterior surface of the acetabular posterior column and the sagittal plane was (60.2 ± 2.5)°. In the 45° obturator oblique view, the posterior iliac line corresponded with the outer edge of the iliac crest superiorly and the outer edge of the ischium inferiorly, while the posterior wall was projected posterior to the midpoint of the posterior iliac line. In the α° obturator oblique view, the posterior iliac line maintained this alignment but intersected centrally with the posterior acetabular wall. The 2.5 mm Kirschner wire remained within the osseous corridor under the 45° view but potentially extended beyond it under the α° view. Conclusion: When the posterior column screw is visualized posterior to the posterior iliac line in the 45° obturator oblique view, further assessment using a α° view is necessary. If the screw appears anterior to the posterior iliac line in the α° view, it indicates that the posterior cortical surface has not been breached.
- Open Access
- 17 February 2026
- Published by Elsevier in Journal of ISAKOS
- p. 101086
Arthroscopic Treatment of Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia: A Modified Surgical Technique and Case Series
- 17 February 2026
- Published by Elsevier in Journal of ISAKOS
- p. 101086
Open AccessArthroscopic Treatment of Avulsion Fracture of the Posterior Cruciate Ligament from the Tibia: A Modified Surgical Technique and Case Series
- Open Access
- 7 October 2025
- Published by Elsevier in JPRAS Open
- Vol. 46, 446-449
Complete replantation of a small tissue segment at the auricular apex: A case report
- 7 October 2025
- Published by Elsevier in JPRAS Open
- Vol. 46, 446-449
Open AccessComplete replantation of a small tissue segment at the auricular apex: A case report
- 1 September 2020
- Published by Elsevier in Journal of Controlled Release
- Vol. 325, 380-393
Nanoparticle-siRNA: A potential strategy for rheumatoid arthritis therapy?
- 1 September 2020
- Published by Elsevier in Journal of Controlled Release
- Vol. 325, 380-393
Nanoparticle-siRNA: A potential strategy for rheumatoid arthritis therapy?