Xuecheng Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuecheng Sun has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Longxin An
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
4 shared publicationsHaoyong Ma
Yanbian University hospital, Yanbian University, Yanbian, China
2 shared publicationsLi Xu
Department of Trauma Orthopedics, Weifang People's Hospital, Shandong Second Medical University, Weifang, China
2 shared publications- Naibo Feng
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
2 shared publications - Naibo Feng
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
2 shared publications Qian Wu
WeiFang People’s Hospital, Shandong Second Medical University, Weifang, China
2 shared publications
Latest Publications
- Open Access
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e50043
A single-center retrospective observational study of modified anterolateral arthroscopic double-loop plate fixation for acute acromioclavicular joint dislocation
This study aimed to evaluate the clinical efficacy of double-loop plate fixation via the subacromial coracoid approach (modified anterolateral shoulder arthroscopy) for acute acromioclavicular joint dislocation of Rockwood Grade III or higher. A retrospective single-center observational study included 68 patients treated at Weifang People’s Hospital from October 2022 to April 2024. Outcomes included pre- and postoperative pain (Visual Analog Scale), functional recovery (Constant Score), range of motion, and radiographic reduction (coracoclavicular distance [CCD] and acromioclavicular distance [ACD]). Repeated-measures analysis of variance evaluated longitudinal changes; paired t -tests compared CCD and ACD between 2 days and 6 months postoperatively. P < .05 was considered significant. All 68 patients completed ≥ 6-month follow-up. Significant improvements were observed in Visual Analog Scale, Constant Score, and range of motion at 1, 3, and 6 months postoperatively (all P < .01), with stable CCD and ACD radiographically. The modified arthroscopic double-loop plate fixation shows short-term efficacy in acute Rockwood III–VI acromioclavicular joint dislocation, with pain relief, functional recovery, and stable radiographic reduction. Limitations include retrospective, single-center design, lack of comparator, and short-term follow-up; long-term efficacy requires prospective controlled trials.
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e50043
Open AccessA single-center retrospective observational study of modified anterolateral arthroscopic double-loop plate fixation for acute acromioclavicular joint dislocation
This study aimed to evaluate the clinical efficacy of double-loop plate fixation via the subacromial coracoid approach (modified anterolateral shoulder arthroscopy) for acute acromioclavicular joint dislocation of Rockwood Grade III or higher. A retrospective single-center observational study included 68 patients treated at Weifang People’s Hospital from October 2022 to April 2024. Outcomes included pre- and postoperative pain (Visual Analog Scale), functional recovery (Constant Score), range of motion, and radiographic reduction (coracoclavicular distance [CCD] and acromioclavicular distance [ACD]). Repeated-measures analysis of variance evaluated longitudinal changes; paired t -tests compared CCD and ACD between 2 days and 6 months postoperatively. P < .05 was considered significant. All 68 patients completed ≥ 6-month follow-up. Significant improvements were observed in Visual Analog Scale, Constant Score, and range of motion at 1, 3, and 6 months postoperatively (all P < .01), with stable CCD and ACD radiographically. The modified arthroscopic double-loop plate fixation shows short-term efficacy in acute Rockwood III–VI acromioclavicular joint dislocation, with pain relief, functional recovery, and stable radiographic reduction. Limitations include retrospective, single-center design, lack of comparator, and short-term follow-up; long-term efficacy requires prospective controlled trials.
- Open Access
- 17 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0347522
Utilization of the posterior iliac line for visualizing posterior column screws in obturator oblique view
Purpose: To evaluate whether posterior column screws penetrate the posterior cortical surface of the acetabulum when assessed using obturator oblique radiographic imaging. Methods: Computed tomography (CT) scans were performed on the right acetabulum of 50 healthy adults to measure the angle (α) between the posterior wall of the acetabulum and the sagittal plane at the level of the femoral head’s maximal diameter. In addition, five cadaveric pelvises were subjected to C-arm fluoroscopic imaging. A 6 cm long, 1.5 mm Kirschner wire was positioned along the posterior surface of the acetabular posterior column, aligned with the greater sciatic notch, and imaged in both the 45° and α-degree obturator oblique views. The radiographic line visualized from the Kirschner wire in the obturator oblique view was defined as the posterior iliac line , and its anatomical relationship with the posterior surface of the posterior column was analyzed. Subsequently, a 2.5 mm Kirschner wire was inserted into the posterior column at the standard entry point for screw placement using an electric drill, with the wire tip intentionally positioned between the posterior iliac line and the posterior rim in the 45° obturator oblique view. The trajectory of the wire was assessed under both 45° and α-degree obturator oblique views to determine its relation to the osseous corridor. Results: The measured angle between the posterior surface of the acetabular posterior column and the sagittal plane was (60.2 ± 2.5)°. In the 45° obturator oblique view, the posterior iliac line corresponded with the outer edge of the iliac crest superiorly and the outer edge of the ischium inferiorly, while the posterior wall was projected posterior to the midpoint of the posterior iliac line. In the α° obturator oblique view, the posterior iliac line maintained this alignment but intersected centrally with the posterior acetabular wall. The 2.5 mm Kirschner wire remained within the osseous corridor under the 45° view but potentially extended beyond it under the α° view. Conclusion: When the posterior column screw is visualized posterior to the posterior iliac line in the 45° obturator oblique view, further assessment using a α° view is necessary. If the screw appears anterior to the posterior iliac line in the α° view, it indicates that the posterior cortical surface has not been breached.
- 17 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0347522
Open AccessUtilization of the posterior iliac line for visualizing posterior column screws in obturator oblique view
Purpose: To evaluate whether posterior column screws penetrate the posterior cortical surface of the acetabulum when assessed using obturator oblique radiographic imaging. Methods: Computed tomography (CT) scans were performed on the right acetabulum of 50 healthy adults to measure the angle (α) between the posterior wall of the acetabulum and the sagittal plane at the level of the femoral head’s maximal diameter. In addition, five cadaveric pelvises were subjected to C-arm fluoroscopic imaging. A 6 cm long, 1.5 mm Kirschner wire was positioned along the posterior surface of the acetabular posterior column, aligned with the greater sciatic notch, and imaged in both the 45° and α-degree obturator oblique views. The radiographic line visualized from the Kirschner wire in the obturator oblique view was defined as the posterior iliac line , and its anatomical relationship with the posterior surface of the posterior column was analyzed. Subsequently, a 2.5 mm Kirschner wire was inserted into the posterior column at the standard entry point for screw placement using an electric drill, with the wire tip intentionally positioned between the posterior iliac line and the posterior rim in the 45° obturator oblique view. The trajectory of the wire was assessed under both 45° and α-degree obturator oblique views to determine its relation to the osseous corridor. Results: The measured angle between the posterior surface of the acetabular posterior column and the sagittal plane was (60.2 ± 2.5)°. In the 45° obturator oblique view, the posterior iliac line corresponded with the outer edge of the iliac crest superiorly and the outer edge of the ischium inferiorly, while the posterior wall was projected posterior to the midpoint of the posterior iliac line. In the α° obturator oblique view, the posterior iliac line maintained this alignment but intersected centrally with the posterior acetabular wall. The 2.5 mm Kirschner wire remained within the osseous corridor under the 45° view but potentially extended beyond it under the α° view. Conclusion: When the posterior column screw is visualized posterior to the posterior iliac line in the 45° obturator oblique view, further assessment using a α° view is necessary. If the screw appears anterior to the posterior iliac line in the α° view, it indicates that the posterior cortical surface has not been breached.
- Open Access
- 19 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Experimental study of anterior wall sliding oblique suture technique in supermicrosurgery
The study aimed to compare the Anterior Wall Sliding Oblique Suture Technique with the conventional vertical needle insertion technique in terms of feasibility and reliability for microvessel anastomosis. Forty male Wistar rats were used in this study. The rats were randomly divided into four groups according to the diameter of the median caudal artery (MCA) and these two methods. These two technologies were used to compare the duration of the surgery, one-time anastomotic patency rates, and delayed patency rates (7 days after the operation). An additional histological study was performed to assess the stenosis and destruction of vessels. All rats survived the surgical anesthetic procedure. The Anterior Wall Sliding Oblique Suture Technique was faster than the conventional technique for supermicrosurgery. Results showed that Group B had a significantly faster anastomosis time (23.8 min ± 2.7 vs. 19.2 min ± 2.0, P < 0.01). Group A1 had a higher one-time anastomotic patency rate (90%) than Group A2 (70%), while Group B2 (80%) had a significantly higher rate than Group B1 (20%) (P = 0.023). Delayed patency rates were also different between groups, with Group A1 having 100% and Group A2 having 50% (P = 0.033), while Group B1 had 30% and Group B2 had 90% (P = 0.020). These results showed that the new method ensured quality in supermicrosurgery, especially in the microvascular group in the histological study. The Anterior Wall Sliding Oblique Suture Technique is more effective than the conventional vertical needle insertion technique for supermicrosurgery. It reduces the operation time and improves the patency rate of vascular anastomosis. Therefore, it can be considered a reliable and effective method when dealing with the microvascular.
- 19 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessExperimental study of anterior wall sliding oblique suture technique in supermicrosurgery
The study aimed to compare the Anterior Wall Sliding Oblique Suture Technique with the conventional vertical needle insertion technique in terms of feasibility and reliability for microvessel anastomosis. Forty male Wistar rats were used in this study. The rats were randomly divided into four groups according to the diameter of the median caudal artery (MCA) and these two methods. These two technologies were used to compare the duration of the surgery, one-time anastomotic patency rates, and delayed patency rates (7 days after the operation). An additional histological study was performed to assess the stenosis and destruction of vessels. All rats survived the surgical anesthetic procedure. The Anterior Wall Sliding Oblique Suture Technique was faster than the conventional technique for supermicrosurgery. Results showed that Group B had a significantly faster anastomosis time (23.8 min ± 2.7 vs. 19.2 min ± 2.0, P < 0.01). Group A1 had a higher one-time anastomotic patency rate (90%) than Group A2 (70%), while Group B2 (80%) had a significantly higher rate than Group B1 (20%) (P = 0.023). Delayed patency rates were also different between groups, with Group A1 having 100% and Group A2 having 50% (P = 0.033), while Group B1 had 30% and Group B2 had 90% (P = 0.020). These results showed that the new method ensured quality in supermicrosurgery, especially in the microvascular group in the histological study. The Anterior Wall Sliding Oblique Suture Technique is more effective than the conventional vertical needle insertion technique for supermicrosurgery. It reduces the operation time and improves the patency rate of vascular anastomosis. Therefore, it can be considered a reliable and effective method when dealing with the microvascular.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Immunology Research
- Vol. 2026 (1) , e1718207
Lnc‐CHRM4‐2:1 Inhibits M2 Polarization and Efferocytosis of Macrophages by Downregulating MerTK and SLC2A1 in Rheumatoid Arthritis
Objective: Rheumatoid arthritis (RA) is a common chronic and systemic autoimmune disease. Long noncoding RNAs (lncRNAs) have been documented to play important roles in the pathogenesis of RA. This study is aimed to investigate the differentially expressed lncRNAs in RA and explore the underlying roles and mechanisms of RA‐specific lncRNAs. Methods: Peripheral blood mononuclear cells (PBMCs) from three RA patients and three healthy controls were detected by transcriptome sequencing analysis. Enrichment analysis was performed to identify the potential functional categories and signal pathways. The expressions of the screened dysregulated lncRNAs in RA were further validated using quantitative real‐time polymerase chain reaction (qRT‐PCR). The effects of the candidate lncRNA lnc‐CHRM4‐2:1 on the proliferation and apoptosis of Raw264.7 cells were determined by cell counting kit‐8 (CCK‐8), 5‐ethynyl‐2′‐deoxyuridine (EdU) proliferation assays, and Annexin V‐APC/PI staining flow cytometry assay. qRT‐PCR and western blot were performed to detect the expression of functional molecules related to M1/M2 macrophage polarization and efferocytosis. Results: The expression of lnc‐CHRM4‐2:1 was significantly higher in PBMCs of RA patients compared to healthy controls. Lnc‐CHRM4‐2:1 was negatively associated with the level of serum CCP of RA patients, suggesting that it was a RA‐specific lncRNA. Overexpression of lnc‐CHRM4‐2:1 could potentially affect cell proliferation and apoptosis, promote M1 polarization, inhibit M2 polarization, and the mRNA and protein expressions of MerTK and SLC2A1 in Raw264.7 cells. Conclusion: Lnc‐CHRM4‐2:1 is an RA‐specific lncRNA, which inhibits macrophage M2 polarization and efferocytosis by downregulating MerTK and SLC2A1. Lnc‐CHRM4‐2:1 may be considered a potential diagnostic biomarker and therapeutic target for RA.
- 1 January 2026
- Published by Wiley in Journal of Immunology Research
- Vol. 2026 (1) , e1718207
Open AccessLnc‐CHRM4‐2:1 Inhibits M2 Polarization and Efferocytosis of Macrophages by Downregulating MerTK and SLC2A1 in Rheumatoid Arthritis
Objective: Rheumatoid arthritis (RA) is a common chronic and systemic autoimmune disease. Long noncoding RNAs (lncRNAs) have been documented to play important roles in the pathogenesis of RA. This study is aimed to investigate the differentially expressed lncRNAs in RA and explore the underlying roles and mechanisms of RA‐specific lncRNAs. Methods: Peripheral blood mononuclear cells (PBMCs) from three RA patients and three healthy controls were detected by transcriptome sequencing analysis. Enrichment analysis was performed to identify the potential functional categories and signal pathways. The expressions of the screened dysregulated lncRNAs in RA were further validated using quantitative real‐time polymerase chain reaction (qRT‐PCR). The effects of the candidate lncRNA lnc‐CHRM4‐2:1 on the proliferation and apoptosis of Raw264.7 cells were determined by cell counting kit‐8 (CCK‐8), 5‐ethynyl‐2′‐deoxyuridine (EdU) proliferation assays, and Annexin V‐APC/PI staining flow cytometry assay. qRT‐PCR and western blot were performed to detect the expression of functional molecules related to M1/M2 macrophage polarization and efferocytosis. Results: The expression of lnc‐CHRM4‐2:1 was significantly higher in PBMCs of RA patients compared to healthy controls. Lnc‐CHRM4‐2:1 was negatively associated with the level of serum CCP of RA patients, suggesting that it was a RA‐specific lncRNA. Overexpression of lnc‐CHRM4‐2:1 could potentially affect cell proliferation and apoptosis, promote M1 polarization, inhibit M2 polarization, and the mRNA and protein expressions of MerTK and SLC2A1 in Raw264.7 cells. Conclusion: Lnc‐CHRM4‐2:1 is an RA‐specific lncRNA, which inhibits macrophage M2 polarization and efferocytosis by downregulating MerTK and SLC2A1. Lnc‐CHRM4‐2:1 may be considered a potential diagnostic biomarker and therapeutic target for RA.
- Open Access
- 14 November 2025
- Published by Springer Nature in Research Square
A New and Improved Technique for Microvascular Anastomosis: An Experimental Comparative Study with the Conventional Vascular Anastomosis Method
Background The study aimed to compare the Crochet technique with the traditional technique in terms of feasibility and reliability for microvessel anastomosis. Methods Forty male Wistar rats were used in this study. The rats were randomly divided into four groups according to the diameter of the median caudal artery (MCA) and these two methods. These two technologies were used to compare the duration of the surgery, one-time anastomotic patency rates, and delayed patency rates (7 days after the operation). An additional histological study was performed to assess the stenosis and destruction of vessels. Results All rats survived the surgical anesthetic procedure. The Crochet technique was faster than the conventional technique for microvascular anastomosis. Results showed that Group B had a significantly faster anastomosis time (23.8min ± 2.7 vs. 19.2min ± 2.0, P<0.01). Group A1 had a higher one-time anastomotic patency rate (90%) than Group A2 (70%), while Group B2 (80%) had a significantly higher rate than Group B1 (20%) (P = 0.023). Delayed patency rates were also different between groups, with Group A1 having 100% and Group A2 having 50% (P = 0.033), while Group B1 had 30% and Group B2 had 90% (P = 0.020). These results showed that the new method ensured quality microvascular anastomosis, especially in the microvascular group in the histological study. Conclusions The Crochet technique is more effective than the traditional method for microvascular anastomosis. It reduces the operation time and improves the patency rate of vascular anastomosis. Therefore, it can be considered a reliable and effective method when dealing with the microvascular.
- 14 November 2025
- Published by Springer Nature in Research Square
Open AccessA New and Improved Technique for Microvascular Anastomosis: An Experimental Comparative Study with the Conventional Vascular Anastomosis Method
Background The study aimed to compare the Crochet technique with the traditional technique in terms of feasibility and reliability for microvessel anastomosis. Methods Forty male Wistar rats were used in this study. The rats were randomly divided into four groups according to the diameter of the median caudal artery (MCA) and these two methods. These two technologies were used to compare the duration of the surgery, one-time anastomotic patency rates, and delayed patency rates (7 days after the operation). An additional histological study was performed to assess the stenosis and destruction of vessels. Results All rats survived the surgical anesthetic procedure. The Crochet technique was faster than the conventional technique for microvascular anastomosis. Results showed that Group B had a significantly faster anastomosis time (23.8min ± 2.7 vs. 19.2min ± 2.0, P<0.01). Group A1 had a higher one-time anastomotic patency rate (90%) than Group A2 (70%), while Group B2 (80%) had a significantly higher rate than Group B1 (20%) (P = 0.023). Delayed patency rates were also different between groups, with Group A1 having 100% and Group A2 having 50% (P = 0.033), while Group B1 had 30% and Group B2 had 90% (P = 0.020). These results showed that the new method ensured quality microvascular anastomosis, especially in the microvascular group in the histological study. Conclusions The Crochet technique is more effective than the traditional method for microvascular anastomosis. It reduces the operation time and improves the patency rate of vascular anastomosis. Therefore, it can be considered a reliable and effective method when dealing with the microvascular.
- Open Access
- 1 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102337
Complex decongestive therapy combined with needle electrode stimulation facilitates postoperative rehabilitation of lymphedema
- 1 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102337
Open AccessComplex decongestive therapy combined with needle electrode stimulation facilitates postoperative rehabilitation of lymphedema