Alex-Barna Kacsó
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alex-Barna Kacsó has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ildiko Peter
Department of Industrial Engineering and Management, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mures, Gheorghe Marinescu 38, 540142 Târgu Mures, Romania
5 shared publications - Gabriela Strnad
Department of Industrial Engineering, Faculty of Engineering and Information Technology, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
1 shared publication - Ladislau Matekovits
Politecnico di Torino
1 shared publication - László Jakab-Farkas
Faculty of Technical and Human Sciences, Sapientia Hungarian University of Transylvania, 540485 Târgu Mureș, Romania
1 shared publication - Roberto Spotorno
Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146 Genoa, Italy
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (10) , 1241
Tailoring TiO2 Nanotube Arrays via Anodization Voltage and Thermal Processing: A Parametric Design Roadmap for Customizable Biomedical Applications
Background/Objectives: Titanium and its flagship alloy (Ti6Al4V) represent the clinical gold standard for orthopedic and dental implants; however, optimizing their surface architecture to serve as high-capacity, reliable platforms for localized therapeutic delivery remains a significant clinical challenge. In this study, we aim to establish a systematic design roadmap linking surface engineering parameters directly to functional drug delivery performance. Methods: To achieve this, a comparative investigation was performed to map the electrochemical growth kinetics, voltage-driven morphological evolution, and processing limits of TiO2 nanotube (TNT) arrays developed on commercially pure titanium (CP-Ti) and Ti6Al4V substrates in an ethylene glycol-based electrolyte containing NH4F. Anodization was carried out at three different potentials (40 V, 50 V, and 60 V) for 30 min, followed by structural and statistical evaluation. Results: Scanning electron microscopy (SEM) combined with Gaussian size-distribution modeling confirmed a strong linear correlation between applied potential and pore dimensions, expanding mean diameters from 59 nm to 88 nm on CP-Ti and from 56 nm to 96 nm on Ti6Al4V. Current–time (I-t) transient analysis revealed distinct growth kinetics, with Ti6Al4V exhibiting enhanced current fluctuations driven by the differential oxidation rates of its dual-phase (α + β) microstructure. Furthermore, post-anodization thermal annealing at 450 °C is identified as a necessary structural processing step to stabilize the amorphous layers into crystalline polymorphs, providing the essential capillary stress resistance required to prevent film delamination during fluidic drug loading (MgSO4 simulation). Conclusions: By establishing a comprehensive parameter-property matrix, this study provides a practical design roadmap that categorizes specific anodization regimes for tailored pharmaceutical and biomedical functions, ranging from direct osteoblast adhesion (40–50 V) to superhydrophilic architectures structurally optimized for high-capacity drug delivery (60 V).
- 30 September 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (10) , 1241
Open AccessTailoring TiO2 Nanotube Arrays via Anodization Voltage and Thermal Processing: A Parametric Design Roadmap for Customizable Biomedical Applications
Background/Objectives: Titanium and its flagship alloy (Ti6Al4V) represent the clinical gold standard for orthopedic and dental implants; however, optimizing their surface architecture to serve as high-capacity, reliable platforms for localized therapeutic delivery remains a significant clinical challenge. In this study, we aim to establish a systematic design roadmap linking surface engineering parameters directly to functional drug delivery performance. Methods: To achieve this, a comparative investigation was performed to map the electrochemical growth kinetics, voltage-driven morphological evolution, and processing limits of TiO2 nanotube (TNT) arrays developed on commercially pure titanium (CP-Ti) and Ti6Al4V substrates in an ethylene glycol-based electrolyte containing NH4F. Anodization was carried out at three different potentials (40 V, 50 V, and 60 V) for 30 min, followed by structural and statistical evaluation. Results: Scanning electron microscopy (SEM) combined with Gaussian size-distribution modeling confirmed a strong linear correlation between applied potential and pore dimensions, expanding mean diameters from 59 nm to 88 nm on CP-Ti and from 56 nm to 96 nm on Ti6Al4V. Current–time (I-t) transient analysis revealed distinct growth kinetics, with Ti6Al4V exhibiting enhanced current fluctuations driven by the differential oxidation rates of its dual-phase (α + β) microstructure. Furthermore, post-anodization thermal annealing at 450 °C is identified as a necessary structural processing step to stabilize the amorphous layers into crystalline polymorphs, providing the essential capillary stress resistance required to prevent film delamination during fluidic drug loading (MgSO4 simulation). Conclusions: By establishing a comprehensive parameter-property matrix, this study provides a practical design roadmap that categorizes specific anodization regimes for tailored pharmaceutical and biomedical functions, ranging from direct osteoblast adhesion (40–50 V) to superhydrophilic architectures structurally optimized for high-capacity drug delivery (60 V).
- Open Access
- 12 August 2026
- Published by IntechOpen
Functionalizing Titanium Alloys for Bioelectronics: Anodization, Conducting Polymers and Biosensor Integration
Although titanium and its alloys remain dominant in orthopedic and dental applications due to their exceptional bulk properties, modern biomedicine requires a transition from passive structural hardware to active bioelectronic platforms capable of reciprocal tissue interaction. This chapter explores the metallurgical and interfacial evolution of titanium-based substrates, tracing the progression from inert bone-replacing metals to sensor-integrated systems. Initial focus is placed on contemporary alloy formulations and the structural necessity for surface engineering to mitigate mechanical stress shielding. Electrochemical modifications – specifically anodization – are detailed, demonstrating how nanoscale architectural tuning optimizes surface wettability, corrosion passivation, and bone–implant interlocking mechanics. To bridge the severe electrical and mechanical disparities between rigid metals and soft physiological tissues, functional coatings are introduced, focusing on intrinsically conducting polymers like poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) to establish high-fidelity bioelectronic interfaces. Finally, future perspectives detail the embedding of telemetric biosensors to enable real-time diagnostic monitoring of osseointegration and the immediate, molecular-level detection of periprosthetic bacterial infections.
- 12 August 2026
- Published by IntechOpen
Open AccessFunctionalizing Titanium Alloys for Bioelectronics: Anodization, Conducting Polymers and Biosensor Integration
Although titanium and its alloys remain dominant in orthopedic and dental applications due to their exceptional bulk properties, modern biomedicine requires a transition from passive structural hardware to active bioelectronic platforms capable of reciprocal tissue interaction. This chapter explores the metallurgical and interfacial evolution of titanium-based substrates, tracing the progression from inert bone-replacing metals to sensor-integrated systems. Initial focus is placed on contemporary alloy formulations and the structural necessity for surface engineering to mitigate mechanical stress shielding. Electrochemical modifications – specifically anodization – are detailed, demonstrating how nanoscale architectural tuning optimizes surface wettability, corrosion passivation, and bone–implant interlocking mechanics. To bridge the severe electrical and mechanical disparities between rigid metals and soft physiological tissues, functional coatings are introduced, focusing on intrinsically conducting polymers like poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) to establish high-fidelity bioelectronic interfaces. Finally, future perspectives detail the embedding of telemetric biosensors to enable real-time diagnostic monitoring of osseointegration and the immediate, molecular-level detection of periprosthetic bacterial infections.
- Open Access
- 1 January 2026
- Published by MDPI AG in Electronic Materials
- Vol. 7 (1) , 1
Titanium Alloys at the Interface of Electronics and Biomedicine: A Review of Functional Properties and Applications
Recent studies show that titanium (Ti)-based alloys combine established mechanical strength, corrosion resistance, and biocompatibility with emerging electrical and electrochemical properties relevant to bioelectronics. The main goal of the present manuscript is to give a wide-ranging overview on the use of Ti-alloys in electronics and biomedicine, focusing on a comprehensive analysis and synthesis of the existing literature to identify gaps and future directions. Concurrently, the identification of possible correlations between the effects of the manufacturing process, alloying elements, and other degrees of freedom influencing the material characteristics are put in evidence, aiming to establish a global view on efficient interdisciplinary efforts to realize high-added-value smart devices useful in the field of biomedicine, such as, for example, implantable apparatuses. This review mostly summarizes advances in surface modification approaches—including anodization, conductive coatings, and nanostructuring that improve conductivity while maintaining biological compatibility. Trends in applications demonstrate how these alloys support smart implants, biosensors, and neural interfaces by enabling reliable signal transmission and long-term integration with tissue. Key challenges remain in balancing electrical performance with biological response and in scaling laboratory modifications for clinical use. Perspectives for future work include optimizing alloy composition, refining surface treatments, and developing multifunctional designs that integrate mechanical, biological, and electronic requirements. Together, these directions highlight the potential of titanium alloys to serve as foundational materials for next-generation bioelectronic medical technologies.
- 1 January 2026
- Published by MDPI AG in Electronic Materials
- Vol. 7 (1) , 1
Open AccessTitanium Alloys at the Interface of Electronics and Biomedicine: A Review of Functional Properties and Applications
Recent studies show that titanium (Ti)-based alloys combine established mechanical strength, corrosion resistance, and biocompatibility with emerging electrical and electrochemical properties relevant to bioelectronics. The main goal of the present manuscript is to give a wide-ranging overview on the use of Ti-alloys in electronics and biomedicine, focusing on a comprehensive analysis and synthesis of the existing literature to identify gaps and future directions. Concurrently, the identification of possible correlations between the effects of the manufacturing process, alloying elements, and other degrees of freedom influencing the material characteristics are put in evidence, aiming to establish a global view on efficient interdisciplinary efforts to realize high-added-value smart devices useful in the field of biomedicine, such as, for example, implantable apparatuses. This review mostly summarizes advances in surface modification approaches—including anodization, conductive coatings, and nanostructuring that improve conductivity while maintaining biological compatibility. Trends in applications demonstrate how these alloys support smart implants, biosensors, and neural interfaces by enabling reliable signal transmission and long-term integration with tissue. Key challenges remain in balancing electrical performance with biological response and in scaling laboratory modifications for clinical use. Perspectives for future work include optimizing alloy composition, refining surface treatments, and developing multifunctional designs that integrate mechanical, biological, and electronic requirements. Together, these directions highlight the potential of titanium alloys to serve as foundational materials for next-generation bioelectronic medical technologies.
- Open Access
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 213508-213522
Characterization of Anodized Ti-Based Alloys: Wettability, Corrosion Resistance, and Biomechanical Performance
This study explores electrochemical and biomechanical properties of five Titanium based alloys, namely pure Titanium, Ti6Al4V, and experimentally developed Ti-10Nb-10Zr-5Ta, Ti-20Nb-20Zr-4Ta, and Ti-29.3Nb-13.6Zr-1.9Fe alloys. The wettability, biocompatibility, and corrosion measurements were performed after electrochemical anodization of the surfaces. The experimental alloys exhibited lower initial ground surface contact angles compared to the commonly used Ti-6Al-4V alloy—anodization in aqueous and organic electrolytes produced nanoporous/nanotubular morphologies, significantly enhancing surface wettability. The Ti-20Nb-20Zr-4Ta alloy anodized in an ethylene glycol-based electrolyte at 60 V demonstrated the best hydrophilic properties, with a contact angle of 52.76 ± 3.90°, notably lower than the 86.06 ± 3.92° of the control Ti-6Al-4V alloy. Electrochemical measurements were carried out to evaluate the corrosion resistance of the metallic alloys in chloride-containing solutions. The results obtained and presented here contribute to the development of Titanium based alloys for biomedical applications, enhancing the current scientific literature.
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 213508-213522
Open AccessCharacterization of Anodized Ti-Based Alloys: Wettability, Corrosion Resistance, and Biomechanical Performance
This study explores electrochemical and biomechanical properties of five Titanium based alloys, namely pure Titanium, Ti6Al4V, and experimentally developed Ti-10Nb-10Zr-5Ta, Ti-20Nb-20Zr-4Ta, and Ti-29.3Nb-13.6Zr-1.9Fe alloys. The wettability, biocompatibility, and corrosion measurements were performed after electrochemical anodization of the surfaces. The experimental alloys exhibited lower initial ground surface contact angles compared to the commonly used Ti-6Al-4V alloy—anodization in aqueous and organic electrolytes produced nanoporous/nanotubular morphologies, significantly enhancing surface wettability. The Ti-20Nb-20Zr-4Ta alloy anodized in an ethylene glycol-based electrolyte at 60 V demonstrated the best hydrophilic properties, with a contact angle of 52.76 ± 3.90°, notably lower than the 86.06 ± 3.92° of the control Ti-6Al-4V alloy. Electrochemical measurements were carried out to evaluate the corrosion resistance of the metallic alloys in chloride-containing solutions. The results obtained and presented here contribute to the development of Titanium based alloys for biomedical applications, enhancing the current scientific literature.
- Top Cited PapersOpen Access
- 18 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (4) , 144
A Review of Past Research and Some Future Perspectives Regarding Titanium Alloys in Biomedical Applications
This review paper provides a comprehensive synthesis of the current advancements in investigations of different titanium-based alloys, including pure titanium, commercially available Ti6Al4V, and modified alloys, such as Ti-Nb-Zr-Fe alloys, for biomedical applications. Several researchers have explored the effects of alloying elements and processing techniques on enhancing the mechanical, chemical, and biological properties of these materials. Ti-Nb-Zr-Fe alloys are of particular interest due to their potential to address critical requirements in medical applications, including reduced Young’s modulus, superior corrosion resistance, biocompatibility, and mechanical strength. Despite substantial progress, the detailed mechanisms for optimizing these properties remain underexplored in the current literature. The main objective of the present review paper is to emphasize the importance of ongoing investigations aimed at overcoming challenges such as biocompatibility concerns, fatigue resistance, and wear under biological conditions. By critically analyzing existing data, this study highlights gaps in knowledge and identifies opportunities for advancing research on these alloys. Specifically, this review paper highlights the need for targeted studies to reduce the Young’s modulus and improve other critical characteristics of Ti-Nb-Zr-Fe alloys to better meet the demands of orthopedic implants, dental prosthetics, and cardiovascular devices. Even if the current scientific literature is ample on this topic, we consider that through this review we can positively contribute to the collective effort in this field trying to fill some gaps, including some updates on the topic, time frames, advantages, and limitations, and pave the way for further advancements that could revolutionize biomedical implant technology. The review encompasses studies performed over the last 5 decades, specifically from 1975 to 2025, to ensure the inclusion of the most relevant and up-to-date research. This approach aims to highlight the significant progress made while situating the findings within the broader context of ongoing investigations.
- 18 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (4) , 144
Top Cited PapersOpen AccessA Review of Past Research and Some Future Perspectives Regarding Titanium Alloys in Biomedical Applications
This review paper provides a comprehensive synthesis of the current advancements in investigations of different titanium-based alloys, including pure titanium, commercially available Ti6Al4V, and modified alloys, such as Ti-Nb-Zr-Fe alloys, for biomedical applications. Several researchers have explored the effects of alloying elements and processing techniques on enhancing the mechanical, chemical, and biological properties of these materials. Ti-Nb-Zr-Fe alloys are of particular interest due to their potential to address critical requirements in medical applications, including reduced Young’s modulus, superior corrosion resistance, biocompatibility, and mechanical strength. Despite substantial progress, the detailed mechanisms for optimizing these properties remain underexplored in the current literature. The main objective of the present review paper is to emphasize the importance of ongoing investigations aimed at overcoming challenges such as biocompatibility concerns, fatigue resistance, and wear under biological conditions. By critically analyzing existing data, this study highlights gaps in knowledge and identifies opportunities for advancing research on these alloys. Specifically, this review paper highlights the need for targeted studies to reduce the Young’s modulus and improve other critical characteristics of Ti-Nb-Zr-Fe alloys to better meet the demands of orthopedic implants, dental prosthetics, and cardiovascular devices. Even if the current scientific literature is ample on this topic, we consider that through this review we can positively contribute to the collective effort in this field trying to fill some gaps, including some updates on the topic, time frames, advantages, and limitations, and pave the way for further advancements that could revolutionize biomedical implant technology. The review encompasses studies performed over the last 5 decades, specifically from 1975 to 2025, to ensure the inclusion of the most relevant and up-to-date research. This approach aims to highlight the significant progress made while situating the findings within the broader context of ongoing investigations.