Sahara Hamas Intifadhah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sahara Hamas Intifadhah has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
A. Mu'TI
Radiology Installation, Abdoel Wahab Sjahranie Hospital, Samarinda 75123
1 shared publication- Dadan Hamdani
Theoretical and Material Physics, Physics Department, Faculty of Mathematic and Natural Sciences, Universitas Mulawarman, Samarinda, Indonesia
1 shared publication Devina Rayzy Perwitasari Sutaji Putri
1 shared publication- Dita Puspita Sari
Innovative Global Program, College of Engineering, Shibaura Institute of Technology, Saitama 337-8570, Japan
1 shared publication - Erlinda Ratnasari Putri
Department of Physics, Faculty of Sciences and Mathematics, Mulawarman University, Samarinda 75123
1 shared publication - Fahmi Astuti
Institut Teknologi Sepuluh Nopember
1 shared publication
Latest Publications
- Open Access
- 17 September 2026
- Published by Faculty of Medicine, Khon Kaen University in Engineering and Applied Science Research
- Vol. 53 (5) , 660-670
Structural and morphological characterization of tea-waste-derived carbon/TiO2 (AT–TiO2) composites prepared by solvent-assisted solid-state dispersion
Tea waste is an abundant agro-industrial residue but its valorization into functional inorganic composites remains largely unexplored. In this study, the waste was torrefied at 230 °C and combined with commercial TiO2 by a solvent-assisted solid-state dispersion route followed by calcination at 500 °C, giving a Tea-Waste-Derived carbon/ TiO2 material denoted AT– TiO2. A total of 3 AT: TiO2 mass ratios (9:1, 8:2 and 7:3) were prepared with pure AT and pure TiO2 controls processed identically, and characterized by XRD and SEM–EDS. XRD results showed that single-phase rutile retained its structure in every composite, with no peak shift and secondary phase. The carbon content was obtained in EDS pattern, due to the effect of using ethanol as a composite solvent. Scherrer analysis of the (110) reflection gave apparent crystallite sizes of 61, 34, 61, and 49 nm for pure TiO2 as well as the 9:1, 8:2 and 7:3 composites. SEM image analysis of 60 objects per sample, fitted to a log-normal distribution, gave median agglomerate sizes of 11.99 ± 0.51, 2.96 ± 0.32, 9.91 ± 0.74, 5.97 ± 0.66 and 11.00 ± 0.81 µm respectively. The 8:2 composite showed both the smallest median and the narrowest distribution (geometric standard deviation 1.56), indicating the most uniform dispersion. This study can serve as the basis for the development of biomass–inorganic composite materials with the potential to be applied in the fields of environmentally friendly adsorption and photocatalysis.
- 17 September 2026
- Published by Faculty of Medicine, Khon Kaen University in Engineering and Applied Science Research
- Vol. 53 (5) , 660-670
Open AccessStructural and morphological characterization of tea-waste-derived carbon/TiO2 (AT–TiO2) composites prepared by solvent-assisted solid-state dispersion
Tea waste is an abundant agro-industrial residue but its valorization into functional inorganic composites remains largely unexplored. In this study, the waste was torrefied at 230 °C and combined with commercial TiO2 by a solvent-assisted solid-state dispersion route followed by calcination at 500 °C, giving a Tea-Waste-Derived carbon/ TiO2 material denoted AT– TiO2. A total of 3 AT: TiO2 mass ratios (9:1, 8:2 and 7:3) were prepared with pure AT and pure TiO2 controls processed identically, and characterized by XRD and SEM–EDS. XRD results showed that single-phase rutile retained its structure in every composite, with no peak shift and secondary phase. The carbon content was obtained in EDS pattern, due to the effect of using ethanol as a composite solvent. Scherrer analysis of the (110) reflection gave apparent crystallite sizes of 61, 34, 61, and 49 nm for pure TiO2 as well as the 9:1, 8:2 and 7:3 composites. SEM image analysis of 60 objects per sample, fitted to a log-normal distribution, gave median agglomerate sizes of 11.99 ± 0.51, 2.96 ± 0.32, 9.91 ± 0.74, 5.97 ± 0.66 and 11.00 ± 0.81 µm respectively. The 8:2 composite showed both the smallest median and the narrowest distribution (geometric standard deviation 1.56), indicating the most uniform dispersion. This study can serve as the basis for the development of biomass–inorganic composite materials with the potential to be applied in the fields of environmentally friendly adsorption and photocatalysis.
- Open Access
- 2 December 2024
- Published by National Research and Innovation Agency in Atom Indonesia
- Vol. 51 (1) , 43-49
Brain Tumor Segmentation on MR and CT Images Using Fuzzy C-Means and Active Contour Methods
A brain tumor is a dangerous brain disease that can attack anyone. It can be described as the abnormal growth of cells in or around the brain, leading to impaired brain function. The first step in diagnosing a brain tumor is to perform an MRI (Magnetic Resonance Imaging) scan. The research aims to analyze the segmentation results of brain tumor MRI and CT (Computed Tomography) images using the Fuzzy C-Means and Active Contour methods. The evaluation is based on ROC parameters, including accuracy, dice score, precision, and sensitivity. The methodology involves analyzing data from secondary image sources, using MATLAB for the segmentation process, and evaluating the results of image segmentation by radiologists. Four ROC measurements were used for each method. The segmentation evaluation results for MRI images show that the Fuzzy C-Means method achieved a precision of 0.92; sensitivity of 0.64; dice score of 0.76; and accuracy of 0.61. The Active Contour method, on the other hand, obtained a precision of 0.97; a sensitivity of 0.99; a dice score of 0.98; and an accuracy of 0.96. For CT images, the Fuzzy C-Means method yielded a precision of 0.72; sensitivity of 0.98; dice score of 0.83; and accuracy of 0.71. The Active Contour method obtained a precision of 0.96; a sensitivity of 0.95; a dice score of 0.96; and an accuracy of 0.92. These results indicate that the Active Contour method, especially with MRI images, provides better segmentation performance. In conclusion, the segmentation results from the Active Contour method can be used as additional information for doctors in diagnosing the presence of tumors.
- 2 December 2024
- Published by National Research and Innovation Agency in Atom Indonesia
- Vol. 51 (1) , 43-49
Open AccessBrain Tumor Segmentation on MR and CT Images Using Fuzzy C-Means and Active Contour Methods
A brain tumor is a dangerous brain disease that can attack anyone. It can be described as the abnormal growth of cells in or around the brain, leading to impaired brain function. The first step in diagnosing a brain tumor is to perform an MRI (Magnetic Resonance Imaging) scan. The research aims to analyze the segmentation results of brain tumor MRI and CT (Computed Tomography) images using the Fuzzy C-Means and Active Contour methods. The evaluation is based on ROC parameters, including accuracy, dice score, precision, and sensitivity. The methodology involves analyzing data from secondary image sources, using MATLAB for the segmentation process, and evaluating the results of image segmentation by radiologists. Four ROC measurements were used for each method. The segmentation evaluation results for MRI images show that the Fuzzy C-Means method achieved a precision of 0.92; sensitivity of 0.64; dice score of 0.76; and accuracy of 0.61. The Active Contour method, on the other hand, obtained a precision of 0.97; a sensitivity of 0.99; a dice score of 0.98; and an accuracy of 0.96. For CT images, the Fuzzy C-Means method yielded a precision of 0.72; sensitivity of 0.98; dice score of 0.83; and accuracy of 0.71. The Active Contour method obtained a precision of 0.96; a sensitivity of 0.95; a dice score of 0.96; and an accuracy of 0.92. These results indicate that the Active Contour method, especially with MRI images, provides better segmentation performance. In conclusion, the segmentation results from the Active Contour method can be used as additional information for doctors in diagnosing the presence of tumors.
- Open Access
- 2 June 2021
- Published by Indonesian Magnetics Society in Journal of Magnetism and Its Applications
- Vol. 1 (1) , 1-4
Local Structure and Magnetism of LiFeSi0.01P0.99O4/C as a Cathode Material on Lithium-Ion Battery
The oxidation state and local structure of LiFeSi0.01P0.99O4/C composites as a cathode on lithium-ion battery were investigated by Fe K-edge X-ray Absorption Near Edge Spectroscopy (XANES) and Extended X-ray Absorption Fine Structure (EXAFS). The LiFeSi0.01P0.99O4/C sample was prepared by solid-state reaction process. Based on the XANES analysis, the absorption of edge energy (E0) of the sample was 7124.92 eV. In addition, linear combination fitting (LCF) analysis of XANES confirmed the oxidation state of iron mixture of 2+ and 3+ as the effect of silicon doped in LiFePO4. The Fourier Transform (FT) of the Fe K-edge EXAFS fitting analysis showed that the nearest neighbors surrounding atom Fe were the main peak with high intensity that confirmed Fe-O bond; the second and third peak with lower intensity confirmed Fe-P and Fe-Fe bonds, respectively. In addition, the SQUID magnetometer result of LiFeSi0.01P0.99O4/C indicated the antiferromagnetic order temperature of LiFeSi0.01P0.99O4/C at ~51 K with the indication of the presence of impurity and structural distortion.
- 2 June 2021
- Published by Indonesian Magnetics Society in Journal of Magnetism and Its Applications
- Vol. 1 (1) , 1-4
Open AccessLocal Structure and Magnetism of LiFeSi0.01P0.99O4/C as a Cathode Material on Lithium-Ion Battery
The oxidation state and local structure of LiFeSi0.01P0.99O4/C composites as a cathode on lithium-ion battery were investigated by Fe K-edge X-ray Absorption Near Edge Spectroscopy (XANES) and Extended X-ray Absorption Fine Structure (EXAFS). The LiFeSi0.01P0.99O4/C sample was prepared by solid-state reaction process. Based on the XANES analysis, the absorption of edge energy (E0) of the sample was 7124.92 eV. In addition, linear combination fitting (LCF) analysis of XANES confirmed the oxidation state of iron mixture of 2+ and 3+ as the effect of silicon doped in LiFePO4. The Fourier Transform (FT) of the Fe K-edge EXAFS fitting analysis showed that the nearest neighbors surrounding atom Fe were the main peak with high intensity that confirmed Fe-O bond; the second and third peak with lower intensity confirmed Fe-P and Fe-Fe bonds, respectively. In addition, the SQUID magnetometer result of LiFeSi0.01P0.99O4/C indicated the antiferromagnetic order temperature of LiFeSi0.01P0.99O4/C at ~51 K with the indication of the presence of impurity and structural distortion.