VBV. U. Bashu

V. U. Bashu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


V. U. Bashu has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments

    by R.R. Marcelo Gregorio, F. Dastgiri, A. Basharina-Freshville, V.U. Bashu, A. Cottle, L.J. Bignell, C. Ghag, G.J. Lane, A.G. McLean, N.J.C. Spooner

    Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon emanation are well-established but have predominantly focused on the 222 Rn isotope, the dominant radon isotope for these backgrounds. However, measurements of 220 Rn (thoron), the second most abundant radon isotope, remain relatively unexplored. 220 Rn emanation measurements are challenging because the 220 Rn must be transferred from the emanation chamber to the active detector within its short 55 s half-life. In this study, a direct in-chamber approach for measuring 220 Rn emanation is presented in which the sample is placed directly within the active detector chamber, thereby minimising losses during transfer. The method was demonstrated with a DURRIDGE RAD8 electrostatic radon detector, which measured 220 Rn emanation from low-activity thoriated rods with an activity of 76 ± 20 mBq. Compared with a conventional flowthrough 220 Rn emanation setup, the in-chamber method increased sensitivity by a factor of 3. Using helium as the carrier gas provided a further sensitivity increase, giving an overall sensitivity gain of ∼ 5. These results indicate that in-chamber 220 Rn emanation measurements provide an effective tool for low-background experiments and have the potential to accelerate radon studies by exploiting the shorter half-life of 220 Rn.

  • Coulomb excitation of Te124 : Emerging collectivity and persisting seniority structure in the 61+ level

    by M. Reece, B. J. Coombes, A. J. Mitchell, A. E. Stuchbery, G. J. Lane, A. Gargano, V. U. Bashu, L. J. Bignell, C. Gautam, L. J. McKie, et al.


  • Open Access

    Characterisation of Hamamatsu R11065-20 PMTs for use in the SABRE South NaI(Tl) Crystal Detectors

    by O. Stanley, W.J.D. Melbourne, P. Urquijo, E. Barberio, V.U. Bashu, L.J. Bignell, I. Bolognino, G. Brooks, S.S. Chhun, F. Dastgiri, et al.

    The SABRE Experiment is a direct detection dark matter experiment using a target composed of multiple NaI(Tl) crystals. The experiment aims to be an independent check of the DAMA/LIBRA results with a detector in the Northern (Laboratori Nazionali Del Gran Sasso, LNGS) and Southern (Stawell Underground Physics Laboratory, SUPL) hemispheres. The SABRE South photomultiplier tubes (PMTs) will be used near the low energy noise threshold and require a detailed calibration of their performance and contributions to the background in the NaI(Tl) dark matter search, prior to installation. We present the development of the pre-calibration procedures for the R11065-20 Hamamatsu PMTs. These PMTs are directly coupled to the NaI(Tl) crystals within the SABRE South experiment. In this paper we present methodologies to characterise the gain, dark rate, and timing properties of the PMTs. We develop a method for in-situ calibration without a light injection source. Additionally we explore the application of machine learning techniques using a Boosted Decision Tree (BDT) trained on the response of single PMTs to understand the information available for background rejection. Finally, we briefly present the simulation tool used to generate digitised PMT data from optical Monte Carlo simulations.


  • Open Access

    Photomultiplier requirements and pre-calibration for the SABRE South Liquid Scintillator Veto

    by L.J. Milligan, P. Urquijo, E. Barberio, V.U. Bashu, L.J. Bignell, I. Bolognino, S.S. Chhun, F. Dastgiri, T. Fruth, G. Fu, et al.

    We present a study of the oil-proof base Hamamatsu R5912 photomultiplier tubes that will be used in the SABRE South linear-alkylbenzene liquid scintillator veto. SABRE South is a dark matter direct detection experiment at the Stawell Underground Physics Laboratory, aiming to test the DAMA/LIBRA dark matter annual modulation signal. We discuss the requirements of the liquid scintillator system and its photomultipliers, outline the methods and analysis used for the characterisation measurements, and results from initial tests. We discuss the impact of these measurements on the performance of the active veto system and explore analysis methods to allow for low threshold operation. Finally, we include results from a small scale liquid scintillator detector prototype used to assess the future performance of pulse shape discrimination in the liquid scintillator veto, and how well accommodated it is by the R5912 PMTs.

  • Open Access

    The SABRE South technical design report executive summary

    by E. Barberio, T. Baroncelli, V.U. Bashu, L.J. Bignell, I. Bolognino, G. Brooks, S.S. Chhun, F. Dastgiri, A. Di Giacinto, G. D'IMperio, et al.

    In this technical design report (TDR) executive summary we describe the SABRE South detector to be built at the Stawell Underground Physics Laboratory (SUPL). The SABRE South detector is designed to test the long-standing DAMA/LIBRA signal of an annually modulating rate consistent with dark matter by using the same target material. Located in the Southern Hemisphere, the detector is uniquely positioned to disentangle modulating seasonal effects. SABRE South uses seven ultra-high purity NaI(Tl) crystals (with a total target mass of either 35 kg or 50 kg), hermetically sealed in copper enclosures that are suspended within a liquid scintillator active veto. High quantum efficiency and low background Hamamatsu R11065 photomultiplier tubes are directly coupled to both ends of the crystal, and enclosed with the crystal in an oxygen free copper enclosure. The active veto system consists of 11.6 kL of linear alkylbenzene (LAB) doped with a mixture of fluorophores and contained in a steel vessel, which is instrumented with at least 18 Hamamatsu R5912 photomultipliers. The active veto tags key radiogenic backgrounds intrinsic to the crystals, such as 40K, and is expected to suppress the total background by 27% in the 1–6 keV region of interest. In addition to the liquid scintillator veto, a muon veto is positioned above the detector shielding. This muon veto consists of eight EJ-200 scintillator modules, with Hamamatsu R13089 photomultipliers coupled to both ends. With an expected total background of 0.72 cpd/kg/keV, SABRE South can test the DAMA/LIBRA signal with 5σ discovery or 3σ exclusion after two years of data taking.