Daniel Ferrusca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Ferrusca has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Velazquez
Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico
3 shared publications - Arturo Iván Gómez Ruiz
72 Instituto Nacional de Astrofísica, Óptica y Electrónica. Apartado Postal 51 y 216, 72000. Puebla Pue., México
2 shared publications - Eduardo Ibarra-Medel
Instituto Nacional de Astrofísica Óptica y Electrónica 5 , Tonantzintla
2 shared publications - Alexandra Pope
Department of Astronomy, University of Massachusetts, Amherst, MA 01003, USA
1 shared publication - Alfonso Torres Jacome
National Institute for Astrophysics, Optics and Electronics (INAOE), Electronics Department, Luis Enrique Erro No. 1, Puebla, C.P. 72840, Mexico
1 shared publication Alfredo Montaña
Consejo Nacional de Ciencia y Tecnología (Mexico)
1 shared publication
Latest Publications
- Open Access
Cryogenic and Vacuum Validation of Thermally Robust Antenna Substrates for Space Applications
Recent developments in space technology have highlighted challenges in characterizing RF devices under cryogenic conditions, including complex laboratory setups, the sensitivity of millimeter-wave signals to measurement variations, and material reliability in space environments. Addressing these challenges is essential to meet the growing demand for low-cost, reliable RF device characterization for space applications. In this paper, we present the results of experimental studies of microstrip antennas manufactured on two different substrates: Rogers RO4350B and FR4. The antennas exhibited a resonance frequency of 5.76 GHz and 5.96 GHz respectively, and −10 dB bandwidths of approximately 140 MHz and 100 MHz, respectively. The ceramic substrate RO4350B demonstrated thermal reversibility, as its resonance frequency returned to the nominal value after a complete cooling/heating cycle, with a frequency shift of only 7.2 MHz (0.12%). In contrast, the fiberglass substrate FR4 exhibited a frequency shift larger than its bandwidth, rendering it unreliable for space applications. In terms of impedance behavior, the RO4350B antenna is therefore a suitable candidate for further qualification for spaceborne applications such as synthetic aperture radar (SAR). Although the FR4 substrate did not meet the required performance standards, its low cost may make it appropriate for low-altitude applications, such as use in unmanned aerial vehicles (UAVs).
Open AccessCryogenic and Vacuum Validation of Thermally Robust Antenna Substrates for Space Applications
Recent developments in space technology have highlighted challenges in characterizing RF devices under cryogenic conditions, including complex laboratory setups, the sensitivity of millimeter-wave signals to measurement variations, and material reliability in space environments. Addressing these challenges is essential to meet the growing demand for low-cost, reliable RF device characterization for space applications. In this paper, we present the results of experimental studies of microstrip antennas manufactured on two different substrates: Rogers RO4350B and FR4. The antennas exhibited a resonance frequency of 5.76 GHz and 5.96 GHz respectively, and −10 dB bandwidths of approximately 140 MHz and 100 MHz, respectively. The ceramic substrate RO4350B demonstrated thermal reversibility, as its resonance frequency returned to the nominal value after a complete cooling/heating cycle, with a frequency shift of only 7.2 MHz (0.12%). In contrast, the fiberglass substrate FR4 exhibited a frequency shift larger than its bandwidth, rendering it unreliable for space applications. In terms of impedance behavior, the RO4350B antenna is therefore a suitable candidate for further qualification for spaceborne applications such as synthetic aperture radar (SAR). Although the FR4 substrate did not meet the required performance standards, its low cost may make it appropriate for low-altitude applications, such as use in unmanned aerial vehicles (UAVs).
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 26 (3) , 807-814
Electrical Behavior at Cryogenic Temperature of the Radiation-Tolerant Hourglass MOS Transistor
This article presents experimental Id-Vgs measurements and an analysis of the electrical characteristics of a MOS (Metal-Oxide-Semiconductor) transistor featuring a novel gate geometry referred to as the hourglass shape. This new transistor was designed to increase total ionizing radiation (TID) tolerance without modifying the manufacturing process. Experiments were conducted using a test chip with individual transistors, under temperature sweeps down to 3.6 K. Key performance metrics—including threshold voltage, subthreshold swing, and zero temperature coefficient (ZTC)—were compared against those of a conventional rectangular transistor used as a reference and a diamond transistor with similar geometry, and fabricated on the same chip. The experimental results show that the hourglass-shaped transistor presents a 27.17% reduction in normalized power consumption compared to the rectangular transistor, while the reduction is 3.61% compared to the diamond-shaped transistor. Additionally, the hourglass transistor presents a normalized increment of 115% and 10.4% in current difference with respect to the rectangular and diamond transistor, respectively across the evaluated temperature range. This study highlights the improved current efficiency of the hourglass design while maintaining lower power consumption under cryogenic conditions. The enhanced thermal stability, the stability of threshold voltage (Vth) and subthreshold swing (SS) shifts and energy efficiency of the proposed device across a wide temperature range are also shown.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 26 (3) , 807-814
Electrical Behavior at Cryogenic Temperature of the Radiation-Tolerant Hourglass MOS Transistor
This article presents experimental Id-Vgs measurements and an analysis of the electrical characteristics of a MOS (Metal-Oxide-Semiconductor) transistor featuring a novel gate geometry referred to as the hourglass shape. This new transistor was designed to increase total ionizing radiation (TID) tolerance without modifying the manufacturing process. Experiments were conducted using a test chip with individual transistors, under temperature sweeps down to 3.6 K. Key performance metrics—including threshold voltage, subthreshold swing, and zero temperature coefficient (ZTC)—were compared against those of a conventional rectangular transistor used as a reference and a diamond transistor with similar geometry, and fabricated on the same chip. The experimental results show that the hourglass-shaped transistor presents a 27.17% reduction in normalized power consumption compared to the rectangular transistor, while the reduction is 3.61% compared to the diamond-shaped transistor. Additionally, the hourglass transistor presents a normalized increment of 115% and 10.4% in current difference with respect to the rectangular and diamond transistor, respectively across the evaluated temperature range. This study highlights the improved current efficiency of the hourglass design while maintaining lower power consumption under cryogenic conditions. The enhanced thermal stability, the stability of threshold voltage (Vth) and subthreshold swing (SS) shifts and energy efficiency of the proposed device across a wide temperature range are also shown.
- Open Access
- 14 April 2026
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 47 (4) , 27
Terahertz and mm-Wave Research in Latin America
- 14 April 2026
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 47 (4) , 27
Open AccessTerahertz and mm-Wave Research in Latin America
- Open Access
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Refurbishment and commissioning of a dual-band 23/31 GHz tipping radiometer at potential radio astronomical sites
This paper reports on the refurbishment of a dual-band 23/31 GHz tipping radiometer previously used to measure atmospheric water vapor content at the Hartebeesthoek Radio Astronomy Observatory. We describe the motivation for the refurbishment, provide technical details of the modifications made to the instrument, and present preliminary test results of field measurements at the site of the High Energy Stereoscopic System Observatory in Namibia. Together with other radiometric measurements, this instrument will contribute to the site characterization of potential radio astronomical observatories in southern Africa.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
Open AccessRefurbishment and commissioning of a dual-band 23/31 GHz tipping radiometer at potential radio astronomical sites
This paper reports on the refurbishment of a dual-band 23/31 GHz tipping radiometer previously used to measure atmospheric water vapor content at the Hartebeesthoek Radio Astronomy Observatory. We describe the motivation for the refurbishment, provide technical details of the modifications made to the instrument, and present preliminary test results of field measurements at the site of the High Energy Stereoscopic System Observatory in Namibia. Together with other radiometric measurements, this instrument will contribute to the site characterization of potential radio astronomical observatories in southern Africa.
- Open Access
- 31 August 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 146
Study and development of programming topologies in FPGA for the reduction and analysis of data from heterodyne instruments for radio astronomy
SPIE Digital Library Proceedings
- 31 August 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 146
Open AccessStudy and development of programming topologies in FPGA for the reduction and analysis of data from heterodyne instruments for radio astronomy
SPIE Digital Library Proceedings
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Development of a Cryogenic System for the Characterization of Advanced CMOS technologies down to 350 mK
In this manuscript, we present an experimental setup capable to extract main electrical parameters and thermal effects from semiconductor devices within a range of temperatures from 300 K down to 350 mK. Key aspects of the system such as sample holder design and wire material selection, are discussed. One of the most critical design limitations is the maximum thermal power handling, since at sub-Kelvin temperatures the cooling power is limited by a 3 He 4 He fridge. The largest amount of heat transferred into the system comes from the electrical wiring, is reduced by the combined use of Copper and Manganin wires. This way we reach an optimized balance between electrical resistance and heat conduction. Therefore we ensure the DUT reaches the Ultra-Cold Stage (UCS) temperature while the electrical measurements are minimally affected by the electrical resistance. Under this condition the cryogenic system allows a reliable electrical characterization of a 14 nm SOI p-FinFET down to 350 mK.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Development of a Cryogenic System for the Characterization of Advanced CMOS technologies down to 350 mK
In this manuscript, we present an experimental setup capable to extract main electrical parameters and thermal effects from semiconductor devices within a range of temperatures from 300 K down to 350 mK. Key aspects of the system such as sample holder design and wire material selection, are discussed. One of the most critical design limitations is the maximum thermal power handling, since at sub-Kelvin temperatures the cooling power is limited by a 3 He 4 He fridge. The largest amount of heat transferred into the system comes from the electrical wiring, is reduced by the combined use of Copper and Manganin wires. This way we reach an optimized balance between electrical resistance and heat conduction. Therefore we ensure the DUT reaches the Ultra-Cold Stage (UCS) temperature while the electrical measurements are minimally affected by the electrical resistance. Under this condition the cryogenic system allows a reliable electrical characterization of a 14 nm SOI p-FinFET down to 350 mK.
- 28 April 2021
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 649, A12
Local dew-point temperature, water vapor pressure, and millimeter-wavelength opacity at the Sierra Negra volcano
Aims. Some astronomical facilities are in operation at the Sierra Negra volcano (SNV), at ∼4.5 km over the sea level (o.s.l.) in Mexico. We asses whether it is possible to estimate the opacity for millimeter-wavelength observations based on the meteorological parameters at the site. A criterion for allowing astronomical observations at SNV depends on the atmospheric opacity at 225 GHz, which has to be τ225 ≤ 0.30 Nepers. The correlation of the opacity at SNV, measured with a radiometer at 225 GHz, τ225, with the local dew point temperature, TDP, the water vapor pressure, PH2O and the water vapor content (WVC) at SNV is studied with the aim to determine whether these parameters can be used to estimate the opacity at similar high-altitude locations for astronomical observations at millimeter wavelengths. Methods. We used radiosonde data taken in various decades in Mexico City (MX) and Veracruz City (VR) to compute the WVC in 0.5 km altitude (h) intervals from 0 km for VR and from 2.0 km for MX to 9.5 km o.s.l. to study the altitude profile WVC(h) at SNV by interpolating data of MX and VR. We also fit exponential functions to observed WVC (WVCobs(h)), obtaining a fit WVC (WVCftd(h)). The WVCobs(h) and WVCftd(h) were integrated, from lower limits of hlow = 2.5–5.5 km to the upper limit of 9.5 km as a measure of the input of WVCobs(h ≥ hlow) to the precipitable water vapor. Results. The largest differences between WVCobs and WVCftd values occur at low altitudes. The input of WVCobs(h) to the precitpitable water vapor for h ≥ 4.5 km ranges from 15% to 29%. At 4.5–5.0 km, the input is between 4% and 8%. This means that it is about a third of the WVC (h ≥ 4.5 km). The input above our limit (from 9.5–30.0 km) is estimated with WVCftd(h) and is found to be lower than 1%. The correlation of τ225 with TDP, PH2O, and WVCSNV takes values between 0.6 and 0.8. A functional relation is proposed based on simultaneous data taken in 2013–2015, according to which it is possible to estimate the opacity with the TDP, PH2O, or WVCSNV at the site. Conclusions. With local meteorological parameters, it is possible to know whether the opacity meets the condition τ225 ≤ 0.30 Nepers, with an uncertainty of ±0.16 Nepers. The uncertainty is low for low opacities and increases with increasing opacity.
- 28 April 2021
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 649, A12
Local dew-point temperature, water vapor pressure, and millimeter-wavelength opacity at the Sierra Negra volcano
Aims. Some astronomical facilities are in operation at the Sierra Negra volcano (SNV), at ∼4.5 km over the sea level (o.s.l.) in Mexico. We asses whether it is possible to estimate the opacity for millimeter-wavelength observations based on the meteorological parameters at the site. A criterion for allowing astronomical observations at SNV depends on the atmospheric opacity at 225 GHz, which has to be τ225 ≤ 0.30 Nepers. The correlation of the opacity at SNV, measured with a radiometer at 225 GHz, τ225, with the local dew point temperature, TDP, the water vapor pressure, PH2O and the water vapor content (WVC) at SNV is studied with the aim to determine whether these parameters can be used to estimate the opacity at similar high-altitude locations for astronomical observations at millimeter wavelengths. Methods. We used radiosonde data taken in various decades in Mexico City (MX) and Veracruz City (VR) to compute the WVC in 0.5 km altitude (h) intervals from 0 km for VR and from 2.0 km for MX to 9.5 km o.s.l. to study the altitude profile WVC(h) at SNV by interpolating data of MX and VR. We also fit exponential functions to observed WVC (WVCobs(h)), obtaining a fit WVC (WVCftd(h)). The WVCobs(h) and WVCftd(h) were integrated, from lower limits of hlow = 2.5–5.5 km to the upper limit of 9.5 km as a measure of the input of WVCobs(h ≥ hlow) to the precipitable water vapor. Results. The largest differences between WVCobs and WVCftd values occur at low altitudes. The input of WVCobs(h) to the precitpitable water vapor for h ≥ 4.5 km ranges from 15% to 29%. At 4.5–5.0 km, the input is between 4% and 8%. This means that it is about a third of the WVC (h ≥ 4.5 km). The input above our limit (from 9.5–30.0 km) is estimated with WVCftd(h) and is found to be lower than 1%. The correlation of τ225 with TDP, PH2O, and WVCSNV takes values between 0.6 and 0.8. A functional relation is proposed based on simultaneous data taken in 2013–2015, according to which it is possible to estimate the opacity with the TDP, PH2O, or WVCSNV at the site. Conclusions. With local meteorological parameters, it is possible to know whether the opacity meets the condition τ225 ≤ 0.30 Nepers, with an uncertainty of ±0.16 Nepers. The uncertainty is low for low opacities and increases with increasing opacity.
- Open Access
Fabrication of Microbolometer Arrays Based on Polymorphous Silicon–Germanium
This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.
Open AccessFabrication of Microbolometer Arrays Based on Polymorphous Silicon–Germanium
This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10700, 107000C-10
The Large Millimeter telescope Alfonso Serrano: scientific operation of the LMT 50-m, first results and next steps (Conference Presentation)
The Large Millimeter Telescope (LMT) Alfonso Serrano is a bi-national (Mexico & USA) telescope facility operated by the Instituto Nacional de Astrofisica, Optica y Electronica (INAOE) and the University of Massachusetts. The LMT is designed as a 50-m diameter single-dish millimeter-wavelength telescope that is optimized to conduct scientific observations at frequencies between ~70 and 350 GHz. The LMT is constructed on the summit of Sierra Negra at an altitude of 4600m in the Mexican state of Puebla. The site offers excellent mm-wavelength atmospheric transparency all-year round, and the opportunity to conduct submillimeter wavelength observations during the winter months. Following first-light observations in mid-2011, the LMT began regular scientific operations in 2014 with a shared-risk Early Science observing program using the inner 32-m diameter of the primary reflector with an active surface control system. The LMT has already performed successful VLBI observations at 3mm with the High Sensitivity Array and also at 1.3mm as part of the Event Horizon Telescope. Since early 2018 the LMT has begun full scientific operations as a 50-m diameter telescope, making the LMT 50-m the world´s largest single-dish telescope operating at 1.1mm. I will describe the current status of the telescope project, including the early scientific results from the LMT 50-m, as well the instrumentation development program, the plan to improve the overall performance of the telescope, and the on-going transition towards the formation of the LMT Observatory to support the scientific community in their use of the LMT to study the formation and evolution of structure at all cosmic epochs.
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10700, 107000C-10
The Large Millimeter telescope Alfonso Serrano: scientific operation of the LMT 50-m, first results and next steps (Conference Presentation)
The Large Millimeter Telescope (LMT) Alfonso Serrano is a bi-national (Mexico & USA) telescope facility operated by the Instituto Nacional de Astrofisica, Optica y Electronica (INAOE) and the University of Massachusetts. The LMT is designed as a 50-m diameter single-dish millimeter-wavelength telescope that is optimized to conduct scientific observations at frequencies between ~70 and 350 GHz. The LMT is constructed on the summit of Sierra Negra at an altitude of 4600m in the Mexican state of Puebla. The site offers excellent mm-wavelength atmospheric transparency all-year round, and the opportunity to conduct submillimeter wavelength observations during the winter months. Following first-light observations in mid-2011, the LMT began regular scientific operations in 2014 with a shared-risk Early Science observing program using the inner 32-m diameter of the primary reflector with an active surface control system. The LMT has already performed successful VLBI observations at 3mm with the High Sensitivity Array and also at 1.3mm as part of the Event Horizon Telescope. Since early 2018 the LMT has begun full scientific operations as a 50-m diameter telescope, making the LMT 50-m the world´s largest single-dish telescope operating at 1.1mm. I will describe the current status of the telescope project, including the early scientific results from the LMT 50-m, as well the instrumentation development program, the plan to improve the overall performance of the telescope, and the on-going transition towards the formation of the LMT Observatory to support the scientific community in their use of the LMT to study the formation and evolution of structure at all cosmic epochs.