KSKangkang Sun

Kangkang Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kangkang Sun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High Input Impedance Chopper-stabilized Analog Front-end Based on Variable-capacitor Calibration for Bio-consumer Electronics

    by Feng Yan, Jingjing Liu, Weijie Ge, Kangkang Sun, Xinying Su, Junhao He

    Analog front-end (AFE) circuits for bio-consumer electronics require ultra-high input impedance to ensure robust bio-potential acquisition under interference. This paper presents a chopping-stabilized AFE featuring an automatic input-impedance enhancement technique based on a positive feedback loop (PFL) with a continuously tunable variable-capacitor. An oscillation-detection-based calibration loop dynamically adjusts the PFL to compensate front-end parasitic capacitance, driving the system from an unstable condition to an optimal stable boundary with maximized input impedance while avoiding over-compensation. To improve calibration robustness, a frequency ripple suppression scheme is introduced, enabling precise control of the variable-capacitor independent of input frequency variations. The proposed variable-capacitance technique provides femtofarad-level resolution without relying on discrete capacitor arrays, achieving wide tuning range and high linearity. Fabricated in a 0.18 μm CMOS process, the AFE achieves an input impedance of 46.3 GΩ at 50 Hz, representing an 83× improvement over conventional approaches. The prototype occupies 0.71 mm², achieves a mid-band gain of 40 dB, an input-referred noise of 0.93 μVrms, and a power consumption of 3.48 μW. Experimental EEG and ECG measurements using comfortable dry electrodes validate the effectiveness of the proposed AFE for bio-consumer electronic applications.


  • Design of a Low-noise Instrumentation Amplifier with Triple-MOS Pseudo-resistor for Bio-signal Acquisition in Consumer Electronics

    by Feng Yan, Jingjing Liu, Kangkang Sun, Bingjun Xiong, Wenji Mo, Jian Guan, Zhipeng Li

    Low input-referred noise (IRN) and low-power instrumentation amplifier (IA) with small size are crucial for consumer bio-electronic applications. This paper presents a compact, noise-efficient capacitive-coupled IA designed for bio-signal acquisition. The proposed Triple-MOSFET pseudo-resistor (PR) provides ultra-high resistance, a wide operating voltage range, and high linearity. The IA, enhanced by chopper-stabilized technology, effectively reduces noise while minimizing current consumption. An area-efficient DC servo loop with Triple-MOS devices is employed to suppress electrode DC offset. Addi-tionally, parasitic effects are minimized based on layout design, maximizing the advantages of the positive feedback loop. The proposed IA is fabricated using a standard 180 nm CMOS process with an area of 0.49 mm², and operates at a supply of 0.8 V with a current consumption of 1.29 μA. The IRN of this IA is 0.97 μVrms within the 0.5–200 Hz and 2.31 μVrms within the 0.2–5 kHz, achieving competitive noise efficiency factor (1.4) and power efficiency factor (1.56). Furthermore, for a 2 mVpp sine wave input, total harmonic distortion is below -60.2 dB. The precise value of the positive feedback capacitor ensures that the input impedance reaches 628 MΩ at 50 Hz. A prototype test system based on the IA successfully acquired high-quality ECG and EEG signals from subjects. This efficient, low-noise, low-power acquisition chip has broad applications in portable cardiac monitors, brain-machine interfaces, and other biosensors, playing a significant role in enhancing the performance and reliability of these electronic devices.


  • An Asynchronous Energy-Harvesting Pixel for CMOS Image Sensors

    by Zhipeng Li, Jingjing Liu, Junhao He, Qinhan Xu, Yupeng Miao, Chang Liu, Bingjun Xiong, Wenkai Yue, Jian Guan, Feng Yan, et al.

  • A Fully Integrated Storage-Free Energy Harvesting System With Voltage Self-Regulation and Dual-Channel Power Extraction

    by Jian Guan, Jingjing Liu, Wenji Mo, Feng Yan, Kangkang Sun, Weijie Ge, Zhipeng Li

    With the growing demand for self-powered operation in Internet of Things (IoT) nodes and microsensors, photovoltaic energy harvesting (EH) systems have become a key research focus. Although triple-well on-chip solar cells improve photovoltaic conversion efficiency, their multiport output characteristics pose design challenges: conventional parallel output schemes cannot address the mismatch in maximum power point (MPP) voltages among ports, thereby limiting energy extraction efficiency. Moreover, fully integrated EH systems lack external storage, and input–output coupling renders traditional voltage regulation unsuitable. To address these challenges, this article presents a fully integrated dual-channel EH system that employs a dual-port, independently boosted parallel architecture combined with a frequency-driven lightweight self-regulation mechanism, eliminating the need for conventional regulators. Measurement results show that the system achieves a stable output voltage of approximately 1.22 V, a peak end-to-end efficiency of 63.97%, and a 6.31% improvement in maximum output power, while also exhibiting reliable start-up and ripple suppression, providing valuable guidance for the design of efficient power extraction and self-regulation in on-chip photovoltaic EH systems.

  • A 9.68nW 57.51dB SNDR SAR ADC With Dual Bypass Windows Based on Non-Binary Split Capacitors for Biomedical Applications

    by Kangkang Sun, Jingjing Liu, Feng Yan, Haoning Sun, Yafei Zhang, Yuan Ren, Linfei Huang, Yao Pi, Wanqing Wu, Jian Guan

    The paper proposes a low-power Successive Approximation Register (SAR) Analog-to-Digital Conversion (ADC) with dual bypass windows based on non-binary split capacitors. To reduce the power consumption, the bypass windows constituted by the split capacitors can maximize the coverage of biological signals both in the resting state and excited state. When the signal falls within the designated window, unnecessary conversion cycles are skipped. This process is mainly judged and controlled by digital circuits, which is highly robust and does not require calibration. Meanwhile, a low-power dynamic CMOS comparator is proposed, which can effectively reduce the voltage variation of the latch node during the comparator's operation, further reducing power consumption. The proposed SAR ADC, based on a 180nm process, measures a power consumption of 9.68nW at a supply voltage of 0.6V and a sampling rate of 5.21kS/s. The signal-to-noise-and-distortion ratio (SNDR) and the spur-free dynamic range (SFDR) are measured at 57.51dB and 71.68dB, respectively. It also achieves an effective number of bits (ENOB) of 9.26 bits and a Walden figure-of-merit (FoM) of 2.9 fJ/conv.-step. The proposed SAR ADC is also verified by collected electromyogram (EMG), electrocardiogram (ECG), and electroencephalogram (EEG) signals. The average power consumption for quantifying EMG signals is 7.95 nW, providing an attractive solution for low-power SAR ADCs in biomedical applications.


  • A 0.88-nW Ultralow Gm Tunable Transconductor Based on Bootstrap Body Input for Biomedical Sensors

    by Feng Yan, Jingjing Liu, Kangkang Sun, Wenji Mo, Bingjun Xiong, Jian Guan, Zhipeng Li

    Low-transconductance (Gm) amplifiers are essential for implementing low-frequency continuous-time filters, a critical aspect for biomedical sensors. This paper proposes a low-power, low-Gm amplifier based on the bootstrap-body-input technique. The input topology of the transconductor consists of two transistors with body-inputs and a source degeneration resistor. The source of the two transistors connected to the resistor, which bootstraps the terminal voltages and expands the input range. To further reduce the Gm value of the transconductor, an area-efficient series-parallel current mirror is adopted. The transconductor was fabricated in a 0.18 μm CMOS process. Measurement results show that the bootstrap-body-input transconductor achieves a reduction in Gm value of more than 1200 times over conventional body-input transconductor. The proposed transconductor features a tuning range of 27 to 581 pA/V at 0.8 V supply voltage, with a power consumption of only 0.88 nW. The input-referred noise is measured at 25.4 μV/√Hz at 100 Hz and the power supply rejection ratio exceeds 56 dB. Tuning tests reveal that the proposed transconductor allows for programming the control voltage of the remaining gate terminals to adjust the Gm value, compensating for variations in process, voltage, and temperature.

  • A Sub-0.9-ps Static Phase Offset 500 MHz Delay-Locked Loop With a Large Gain Phase Detector

    by Jingjing Liu, Ruihuang Wu, Haoning Sun, Bingjun Xiong, Feng Yan, Kangkang Sun, Zhipeng Li, Jian Guan

    This article presents an analog delay-locked loop (DLL) designed for high-precision measurement applications, featuring low static phase offset (SPO) and fast locking speed, such as time-to-digital converters (TDCs) and analog-to-digital converters (ADCs). A large gain and dead-zone free phase detector (PD) is proposed. When the DLL reaches the locked state, the phase error between the two input signals of the PD can be reduced to 0.53 ps (0.095°), which has an 18-time improvement compared to the conventional DLL. Therefore, the SPO of the entire DLL can be effectively reduced to be less than 0.87 ps. Furthermore, the auxiliary circuit, consisting of a large phase difference detector (LPDD) and fast-adjusting branches (FABs), accelerates the DLL’s locking process to 42 clock cycles and improves the locking speed by 4.1 times. Designed by a standard 180 nm CMOS technology, the DLL occupies an area of $106.1\times 93.3~\mu $ m. It achieves low power consumption of 1.89mW at 500 MHz, and the root mean square (rms) jitter and P-P jitter are 1.01 and 6.26 ps, respectively.


  • A 0.6-V 9.38-Bit 6.9-kS/s Capacitor-Splitting Bypass Window SAR ADC for Wearable 12-Lead ECG Acquisition Systems

    by Kangkang Sun, Jingjing Liu, Feng Yan, Yuan Ren, Ruihuang Wu, Bingjun Xiong, Zhipeng Li, Jian Guan

    This article proposes a fully differential ten-bit energy-efficient successive approximation register (SAR) analog-to-digital converter (ADC) for wearable 12-lead electrocardiogram (ECG) acquisition system. The proposed ADC structure generates two bypass windows through capacitor splitting technique, which can skip unnecessary quantization steps. The judgment module of bypass windows only requires an XOR gate. By introducing redundant capacitors to participate in quantization, the total capacitance value is reduced by half. The proposed SAR ADC is fabricated using a standard 180-nm CMOS process. The measurement results show that it can achieve an effective number of bits (ENOBs) of 9.38 bits and a spurious-free dynamic range (SFDR) of 76.71 dB with a supply voltage of 0.6 V at a sampling rate ( $\text{F}_{\mathrm {S}}$ ) of 6.94 kS/s. The power consumption is 15.61 nW when subjected to a 1.17- $\text{V}_{\mathrm {PP}}~3.45$ -kHz sinusoidal input, resulting in a figure of merit (FoM) of 3.38 fJ/conv.-step. The average power consumption for quantizing 12-lead ECG signals is approximately 12.66 nW, demonstrating the ability to achieve ultralow-power quantization of ECG signals.