Mathews Castillo-Guerrero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mathews Castillo-Guerrero has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aluizio D’AFfonsêca Netto
Biomedical Engineering Program, Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (Coppe), Federal University of Rio de Janeiro, Rio de Janeiro 21941-914, Brazil
1 shared publication C. J. Tierra-Criollo
Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (Coppe), Federal University of Rio de Janeiro
1 shared publication- Carlos Julio Tierra-Criollo
Biomedical Engineering Program-PEB, Federal University of Rio de Janeiro, Rio de Janeiro 21941-914, RJ, Brazil
1 shared publication D. A. Molina-Vidal
Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (Coppe), Federal University of Rio de Janeiro
1 shared publication- Danilo Andrés Molina-Vidal
Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (Coppe), Federal University of Rio de Janeiro
1 shared publication - Leimer Guambaña-Calle
Biomedical Engineering Research Group—GIIB, Universidad Politécnica Salesiana, Cuenca 010102, Ecuador
1 shared publication
Latest Publications
- 9 August 2025
- Published by Springer Nature
- p. 1047-1056
Evaluation of Selective Attention with Auditory Steady-State Response Using AM2 Tones
- 9 August 2025
- Published by Springer Nature
- p. 1047-1056
Evaluation of Selective Attention with Auditory Steady-State Response Using AM2 Tones
- Open Access
Prototype of a Multimodal and Multichannel Electro-Physiological and General-Purpose Signal Capture System: Evaluation in Sleep-Research-like Scenario
The simultaneous analysis of electrophysiological signals from various physiological systems, such as the brain, skeletal muscles, and cardiac muscles, has become increasingly necessary in both clinical and research settings. However, acquiring multiple modalities of electrophysiological data often necessitates the use of diverse, specialized technological tools, which can complicate the establishment of a comprehensive multimodal experimental setup. This paper introduces a prototype system, named the Multimodal–Multichannel Acquisition Module—MADQ, designed for the simultaneous acquisition of multimodal and multichannel electrophysiological and general-purpose signals. The MADQ comprises three distinct capturing blocks, each equipped with separate reference circuits, supporting a total of up to 40 electrophysiological input channels, alongside 4 channels of analog input and 4 channels of digital input signal. The system is capable of sampling frequencies up to 16 kHz. Key features of the MADQ include individually configurable bipolar recording, lead-off detection capability, and real-time online filtering. The system’s functional performance was characterized through metrics such as Input-Referred Noise (IRN), Noise-Free Bits (NFB), and Effective Number of Bits (ENOB) across varying gain and sampling frequencies. Preliminary experiments, conducted in a setup emulating a sleep study with auditory evoked potential detection, demonstrate the system’s potential for integration into multimodal experimental scenarios.
Open AccessPrototype of a Multimodal and Multichannel Electro-Physiological and General-Purpose Signal Capture System: Evaluation in Sleep-Research-like Scenario
The simultaneous analysis of electrophysiological signals from various physiological systems, such as the brain, skeletal muscles, and cardiac muscles, has become increasingly necessary in both clinical and research settings. However, acquiring multiple modalities of electrophysiological data often necessitates the use of diverse, specialized technological tools, which can complicate the establishment of a comprehensive multimodal experimental setup. This paper introduces a prototype system, named the Multimodal–Multichannel Acquisition Module—MADQ, designed for the simultaneous acquisition of multimodal and multichannel electrophysiological and general-purpose signals. The MADQ comprises three distinct capturing blocks, each equipped with separate reference circuits, supporting a total of up to 40 electrophysiological input channels, alongside 4 channels of analog input and 4 channels of digital input signal. The system is capable of sampling frequencies up to 16 kHz. Key features of the MADQ include individually configurable bipolar recording, lead-off detection capability, and real-time online filtering. The system’s functional performance was characterized through metrics such as Input-Referred Noise (IRN), Noise-Free Bits (NFB), and Effective Number of Bits (ENOB) across varying gain and sampling frequencies. Preliminary experiments, conducted in a setup emulating a sleep study with auditory evoked potential detection, demonstrate the system’s potential for integration into multimodal experimental scenarios.