ARArthur W. Redgate

Arthur W. Redgate

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arthur W. Redgate has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Phase and intensity x-ray linearization with dark field: a fast algorithm for low coherence X-ray phase-contrast and dark field imaging compatible with medical and industrial X-ray sources

    by Arthur W. Redgate, Carolyn A. MacDonald, Jonathan C. Petruccelli

    Both X-ray phase-contrast and dark-field imaging have the potential to significantly advance medical and industrial imaging. Phase-contrast can offer a significant improvement in contrast compared to conventional imaging for low-density materials. Dark-field imaging offers an additional contrast mechanism, based on internal subresolution microtexture. Most existing phase-contrast and dark-field techniques rely on the high coherence from synchrotron or low-power microfocus sources, or expensive, precisely aligned gratings. These restrictions have limited their widespread adoption. Additionally, many of the algorithms used to produce these images are computationally costly, which limits the ability to perform high-throughput imaging. In this work, we demonstrate a method that produces attenuation, differential phase-contrast, and dark-field images simultaneously by utilizing a simple stainless-steel wire mesh to pattern the X-ray beam and an efficient linear algorithm to extract images from reference-pattern distortions in the presence of a sample. We demonstrated compatibility with low-coherence sources by acquiring differential phase-contrast and dark-field images with a 120 µm source. The implementation of our algorithm also produces a 10-fold improvement in reconstruction times over related techniques.

  • Open Access

    Development of x-ray slot scan diffraction imaging for detection of carcinoma

    by Suman Gautam, Arthur W Redgate, Carolyn A MacDonald, Jonathan C Petruccelli

    In this study, we present a simple, low dose, cost-effective slot scan diffraction imaging system compatible with slot-scan attenuation mammography to improve detection and localization of carcinoma. The system captures angle-resolved coherent scatter information to enhance tissue contrast beyond what is achievable with conventional imaging alone. Diffraction imaging, employed simultaneously with conventional attenuation imaging, has the potential to provide new information that could improve the sensitivity and specificity of diagnostic mammography. Performance was evaluated using small ex-vivo benign and cancerous human breast tissue samples. The detection of carcinoma embedded in benign tissue demonstrated the feasibility of this approach for distinguishing breast cancer from benign tissue with a setup that could be readily adapted into a clinically relevant system for diagnostic radiology.


  • Open Access

    Optimization of signal and noise in x-ray phase and dark field imaging with a wire mesh

    by Uttam Pyakurel, Arthur W Redgate, Carolyn A MacDonald, Jonathan C Petruccelli

    Phase differences imparted by tissue are significantly larger than attenuation differences. In addition, small angle scatter from tissue microstructure can provide a dark field signal that is complementary to attenuation and phase. Unfortunately, the low spatial coherence of clinical sources reduces phase and dark field contrast. Our method structures the beam with a single low-cost wire mesh that does not need precise alignment and relaxes the coherence requirement on the source. In addition, focusing polycapillary optics, which can be permanently attached to sources, are employed to allow for the use of high-power primary sources by increasing the phase signal after the focus. However, the coarseness of the mesh reduces the phase and dark field signal-to-noise ratio (SNR) compared with grating-based techniques, so optimization of the phase and dark-field SNR is an important consideration. Here, we consider the impact on the SNR of the distances between the mesh and the source and detector, and of x-ray tube voltages, to optimize the system.