Jonathan C. Petruccelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jonathan C. Petruccelli has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Carolyn A. MacDonald
University at Albany, SUNY
6 shared publications Carolyn A. MacDonald
University at Albany
4 shared publicationsUttam Pyakurel
Department of Physics, University at Albany, 1400 Washington Ave, Albany, Albany, New York, 12222-0100, UNITED STATES
4 shared publicationsAlexander Khmaladze
Department of Physics , University at Albany, State University of New York , Albany , NY , USA
3 shared publicationsAnna Sharikova
Department of Physics , University at Albany, State University of New York , Albany , NY , USA
3 shared publications- Arthur W. Redgate
University at Albany
3 shared publications
Latest Publications
- 12 November 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (22) , 6383
Phase and intensity x-ray linearization with dark field: a fast algorithm for low coherence X-ray phase-contrast and dark field imaging compatible with medical and industrial X-ray sources
Both X-ray phase-contrast and dark-field imaging have the potential to significantly advance medical and industrial imaging. Phase-contrast can offer a significant improvement in contrast compared to conventional imaging for low-density materials. Dark-field imaging offers an additional contrast mechanism, based on internal subresolution microtexture. Most existing phase-contrast and dark-field techniques rely on the high coherence from synchrotron or low-power microfocus sources, or expensive, precisely aligned gratings. These restrictions have limited their widespread adoption. Additionally, many of the algorithms used to produce these images are computationally costly, which limits the ability to perform high-throughput imaging. In this work, we demonstrate a method that produces attenuation, differential phase-contrast, and dark-field images simultaneously by utilizing a simple stainless-steel wire mesh to pattern the X-ray beam and an efficient linear algorithm to extract images from reference-pattern distortions in the presence of a sample. We demonstrated compatibility with low-coherence sources by acquiring differential phase-contrast and dark-field images with a 120 µm source. The implementation of our algorithm also produces a 10-fold improvement in reconstruction times over related techniques.
- 12 November 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (22) , 6383
Phase and intensity x-ray linearization with dark field: a fast algorithm for low coherence X-ray phase-contrast and dark field imaging compatible with medical and industrial X-ray sources
Both X-ray phase-contrast and dark-field imaging have the potential to significantly advance medical and industrial imaging. Phase-contrast can offer a significant improvement in contrast compared to conventional imaging for low-density materials. Dark-field imaging offers an additional contrast mechanism, based on internal subresolution microtexture. Most existing phase-contrast and dark-field techniques rely on the high coherence from synchrotron or low-power microfocus sources, or expensive, precisely aligned gratings. These restrictions have limited their widespread adoption. Additionally, many of the algorithms used to produce these images are computationally costly, which limits the ability to perform high-throughput imaging. In this work, we demonstrate a method that produces attenuation, differential phase-contrast, and dark-field images simultaneously by utilizing a simple stainless-steel wire mesh to pattern the X-ray beam and an efficient linear algorithm to extract images from reference-pattern distortions in the presence of a sample. We demonstrated compatibility with low-coherence sources by acquiring differential phase-contrast and dark-field images with a 120 µm source. The implementation of our algorithm also produces a 10-fold improvement in reconstruction times over related techniques.
- 9 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 70
Coherent scatter x-ray imaging for classification of polymers
Conventional X-ray imaging struggles to distinguish polymers due to their similar attenuation properties, while spectroscopic techniques can be complex to implement. We present a slot-scan X-ray coherent scatter (diffraction) imaging technique for polymer identification that yields imaging contrast based on structural differences. By acquiring spatially resolved diffraction signatures from materials such as PMMA, nylon, and polycarbonate, the method was shown to enable differentiation between polymers. This rapid, non-destructive approach may provide a promising pathway for in situ polymer classification, with potential applications in industrial quality control, recycling, and advanced materials characterization.
- 9 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 70
Coherent scatter x-ray imaging for classification of polymers
Conventional X-ray imaging struggles to distinguish polymers due to their similar attenuation properties, while spectroscopic techniques can be complex to implement. We present a slot-scan X-ray coherent scatter (diffraction) imaging technique for polymer identification that yields imaging contrast based on structural differences. By acquiring spatially resolved diffraction signatures from materials such as PMMA, nylon, and polycarbonate, the method was shown to enable differentiation between polymers. This rapid, non-destructive approach may provide a promising pathway for in situ polymer classification, with potential applications in industrial quality control, recycling, and advanced materials characterization.
- 9 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 74
ZNet: fast physics-informed quantitative phase imaging via residual phase correction
We introduce the ZNet, a physics-informed deep learning framework that accelerates phase reconstruction from intensity measurements through residual learning. The method initializes the reconstruction with a fast classical phase retrieval algorithm and trains a zero-initialized neural network to predict only the residual correction, rather than the full phase. This informed initialization significantly improves optimization efficiency, reducing the required training from thousands of iterations to only 200 epochs while maintaining high reconstruction accuracy. Both simulated and experimental results validate the speed, robustness, and effectiveness of the proposed approach.
- 9 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 74
ZNet: fast physics-informed quantitative phase imaging via residual phase correction
We introduce the ZNet, a physics-informed deep learning framework that accelerates phase reconstruction from intensity measurements through residual learning. The method initializes the reconstruction with a fast classical phase retrieval algorithm and trains a zero-initialized neural network to predict only the residual correction, rather than the full phase. This informed initialization significantly improves optimization efficiency, reducing the required training from thousands of iterations to only 200 epochs while maintaining high reconstruction accuracy. Both simulated and experimental results validate the speed, robustness, and effectiveness of the proposed approach.
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
An efficient computational reconstruction algorithm for x-ray phase and dark-field imaging using structured illumination with conventional large spot sources and polycapillary optics
Conventional x-ray imaging is a useful diagnostic tool that enables the visualization of internal structures through the absorption and transmission of high energy photons. X-ray phase-contrast and dark field imaging offers new contrast modes for low-density materials and materials that contain sub-resolution micro-texture. While these techniques are not new, they have yet to achieve widespread implementation due to their stringent requirements on beam coherence. Currently, these methods require synchrotrons, low power microfocus sources, or expensive gratings that require precision stepping and alignment. The computational process is also restrictive; because the collected data are intensity images, the phase and dark field are not directly observable. Of the reconstruction algorithms that currently exist, many have high computational costs, which creates an additional workflow bottleneck. In this work, we address both of these challenges. We present a rapid computational algorithm based on a Taylor expansion in small refraction angles, Phase and Intensity X-ray Linearization with Dark Field (PIXLD). Using a simple steel mesh as a reference pattern, this algorithm is capable of producing attenuation, differential phase-contrast, and dark field from images taken at just four reference pattern positions. Additionally, low coherence, large spot sources can be combined with polycapillary optics, reducing the effective spot size and improving beam coherence by creating a smaller secondary source. We demonstrate the compatibility of our algorithm with polycapillary optic data collected on a rotating anode with a 240µm spot size.
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
An efficient computational reconstruction algorithm for x-ray phase and dark-field imaging using structured illumination with conventional large spot sources and polycapillary optics
Conventional x-ray imaging is a useful diagnostic tool that enables the visualization of internal structures through the absorption and transmission of high energy photons. X-ray phase-contrast and dark field imaging offers new contrast modes for low-density materials and materials that contain sub-resolution micro-texture. While these techniques are not new, they have yet to achieve widespread implementation due to their stringent requirements on beam coherence. Currently, these methods require synchrotrons, low power microfocus sources, or expensive gratings that require precision stepping and alignment. The computational process is also restrictive; because the collected data are intensity images, the phase and dark field are not directly observable. Of the reconstruction algorithms that currently exist, many have high computational costs, which creates an additional workflow bottleneck. In this work, we address both of these challenges. We present a rapid computational algorithm based on a Taylor expansion in small refraction angles, Phase and Intensity X-ray Linearization with Dark Field (PIXLD). Using a simple steel mesh as a reference pattern, this algorithm is capable of producing attenuation, differential phase-contrast, and dark field from images taken at just four reference pattern positions. Additionally, low coherence, large spot sources can be combined with polycapillary optics, reducing the effective spot size and improving beam coherence by creating a smaller secondary source. We demonstrate the compatibility of our algorithm with polycapillary optic data collected on a rotating anode with a 240µm spot size.
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 15
Simulation analysis of x-ray phase imaging with polycapillary optics
Currently, mammography utilizes subtle attenuation differences in the soft tissue of the breast to produce image contrast, but x-ray phase imaging can have inherently higher visibility. Rather than using gratings, which can be costly and require precision alignment, our x-ray phase system utilizes a low-cost wire mesh imaged with and without an object in place. Distortions of the mesh pattern can be analyzed to produce phase, dark field, and attenuation images, providing two additional channels of information. The use of a polycapillary optic to create a secondary source provides greater coherence. In order to generate test data for neural network training, and to optimize the system, a simulation has been developed which produces mesh and mesh-with-object images in a variety of conditions. Integrated phase retrieved from simulated images is in good agreement with theoretical values.
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 15
Simulation analysis of x-ray phase imaging with polycapillary optics
Currently, mammography utilizes subtle attenuation differences in the soft tissue of the breast to produce image contrast, but x-ray phase imaging can have inherently higher visibility. Rather than using gratings, which can be costly and require precision alignment, our x-ray phase system utilizes a low-cost wire mesh imaged with and without an object in place. Distortions of the mesh pattern can be analyzed to produce phase, dark field, and attenuation images, providing two additional channels of information. The use of a polycapillary optic to create a secondary source provides greater coherence. In order to generate test data for neural network training, and to optimize the system, a simulation has been developed which produces mesh and mesh-with-object images in a variety of conditions. Integrated phase retrieved from simulated images is in good agreement with theoretical values.
- Open Access
- 20 July 2026
- Published by Walter de Gruyter GmbH in NeuroImmune Pharmacology and Therapeutics
- Vol. 5 (3) , 271-286
Cellular dry mass and volume dynamics in methamphetamine-induced apoptosis determined by label-free quantitative phase imaging
Objectives: To determine how methamphetamine-induced apoptosis alters cellular dry mass and volume, and to evaluate whether quantitative phase imaging (QPI) techniques, specifically transport of intensity equation (TIE) imaging and optical diffraction tomography (ODT), can non-invasively quantify these biophysical changes in cultured C6 cells. Methods: C6 glial cells were exposed to increasing concentrations of methamphetamine and imaged over time using TIE-based QPI to measure dry mass dynamics. Complementary measurements of both dry mass and cell volume were obtained using ODT. Dose-response and time-course analyses were performed to characterize biophysical signatures associated with methamphetamine-induced apoptosis. Results: TIE imaging revealed dose-dependent and time-dependent alterations in cellular dry mass during methamphetamine exposure. ODT measurements demonstrated a concurrent decrease in cell volume and an increase in dry mass, consistent with hallmark apoptotic shrinkage. The combined QPI modalities provided internally consistent, label-free quantification of biophysical remodeling during methamphetamine-triggered cell death. Conclusions: Label-free QPI enables robust, non-invasive measurement of dry mass and volume changes during methamphetamine-induced apoptosis. The observed coupling of volume loss with dry mass accumulation provides new insight into the biophysical progression of neuronal cell death and establishes QPI as a powerful tool for studying neurotoxic mechanisms.
- 20 July 2026
- Published by Walter de Gruyter GmbH in NeuroImmune Pharmacology and Therapeutics
- Vol. 5 (3) , 271-286
Open AccessCellular dry mass and volume dynamics in methamphetamine-induced apoptosis determined by label-free quantitative phase imaging
Objectives: To determine how methamphetamine-induced apoptosis alters cellular dry mass and volume, and to evaluate whether quantitative phase imaging (QPI) techniques, specifically transport of intensity equation (TIE) imaging and optical diffraction tomography (ODT), can non-invasively quantify these biophysical changes in cultured C6 cells. Methods: C6 glial cells were exposed to increasing concentrations of methamphetamine and imaged over time using TIE-based QPI to measure dry mass dynamics. Complementary measurements of both dry mass and cell volume were obtained using ODT. Dose-response and time-course analyses were performed to characterize biophysical signatures associated with methamphetamine-induced apoptosis. Results: TIE imaging revealed dose-dependent and time-dependent alterations in cellular dry mass during methamphetamine exposure. ODT measurements demonstrated a concurrent decrease in cell volume and an increase in dry mass, consistent with hallmark apoptotic shrinkage. The combined QPI modalities provided internally consistent, label-free quantification of biophysical remodeling during methamphetamine-triggered cell death. Conclusions: Label-free QPI enables robust, non-invasive measurement of dry mass and volume changes during methamphetamine-induced apoptosis. The observed coupling of volume loss with dry mass accumulation provides new insight into the biophysical progression of neuronal cell death and establishes QPI as a powerful tool for studying neurotoxic mechanisms.
- Open Access
- 6 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045005
Development of x-ray slot scan diffraction imaging for detection of carcinoma
In this study, we present a simple, low dose, cost-effective slot scan diffraction imaging system compatible with slot-scan attenuation mammography to improve detection and localization of carcinoma. The system captures angle-resolved coherent scatter information to enhance tissue contrast beyond what is achievable with conventional imaging alone. Diffraction imaging, employed simultaneously with conventional attenuation imaging, has the potential to provide new information that could improve the sensitivity and specificity of diagnostic mammography. Performance was evaluated using small ex-vivo benign and cancerous human breast tissue samples. The detection of carcinoma embedded in benign tissue demonstrated the feasibility of this approach for distinguishing breast cancer from benign tissue with a setup that could be readily adapted into a clinically relevant system for diagnostic radiology.
- 6 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045005
Open AccessDevelopment of x-ray slot scan diffraction imaging for detection of carcinoma
In this study, we present a simple, low dose, cost-effective slot scan diffraction imaging system compatible with slot-scan attenuation mammography to improve detection and localization of carcinoma. The system captures angle-resolved coherent scatter information to enhance tissue contrast beyond what is achievable with conventional imaging alone. Diffraction imaging, employed simultaneously with conventional attenuation imaging, has the potential to provide new information that could improve the sensitivity and specificity of diagnostic mammography. Performance was evaluated using small ex-vivo benign and cancerous human breast tissue samples. The detection of carcinoma embedded in benign tissue demonstrated the feasibility of this approach for distinguishing breast cancer from benign tissue with a setup that could be readily adapted into a clinically relevant system for diagnostic radiology.
- 15 March 2026
- Published by Optica Publishing Group in Optics Continuum
- Vol. 5 (3) , 918
Comparative analysis of deep decoder and U-Net architectures for propagation-based phase reconstruction from intensity measurements using untrained neural networks
Untrained neural networks (UNNs) have recently emerged as a promising approach for solving inverse problems without the need for large-scale datasets or extensive training. In this work, we systematically investigate the performance of UNNs in the context of phase retrieval from free-space propagation of intensity. We focus on two distinct architectures: the deep decoder and U-Net, evaluating their ability to reconstruct phase information from intensity measurements. Through simulation and experiment, we compare the reconstruction robustness of both architectures under various noise levels and propagation distances. Our findings highlight the strengths and limitations of each architecture, offering insights into the design of effective UNN-based phase retrieval algorithms and guiding future work toward more efficient imaging solutions.
- 15 March 2026
- Published by Optica Publishing Group in Optics Continuum
- Vol. 5 (3) , 918
Comparative analysis of deep decoder and U-Net architectures for propagation-based phase reconstruction from intensity measurements using untrained neural networks
Untrained neural networks (UNNs) have recently emerged as a promising approach for solving inverse problems without the need for large-scale datasets or extensive training. In this work, we systematically investigate the performance of UNNs in the context of phase retrieval from free-space propagation of intensity. We focus on two distinct architectures: the deep decoder and U-Net, evaluating their ability to reconstruct phase information from intensity measurements. Through simulation and experiment, we compare the reconstruction robustness of both architectures under various noise levels and propagation distances. Our findings highlight the strengths and limitations of each architecture, offering insights into the design of effective UNN-based phase retrieval algorithms and guiding future work toward more efficient imaging solutions.
- 30 July 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 42 (8) , ED6-ED7
2024 JOSA A Emerging Researcher Best Paper Prize: editorial
JOSA A Editor-in-Chief Olga Korotkova, Deputy Editor Markus Testorf, and the members of the 2024 Emerging Researcher Best Paper Prize Committee announce the recipient of the 2024 prize for the best paper published by an emerging researcher in the Journal.
- 30 July 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 42 (8) , ED6-ED7
2024 JOSA A Emerging Researcher Best Paper Prize: editorial
JOSA A Editor-in-Chief Olga Korotkova, Deputy Editor Markus Testorf, and the members of the 2024 Emerging Researcher Best Paper Prize Committee announce the recipient of the 2024 prize for the best paper published by an emerging researcher in the Journal.
- Open Access
- 30 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035024
Optimization of signal and noise in x-ray phase and dark field imaging with a wire mesh
Phase differences imparted by tissue are significantly larger than attenuation differences. In addition, small angle scatter from tissue microstructure can provide a dark field signal that is complementary to attenuation and phase. Unfortunately, the low spatial coherence of clinical sources reduces phase and dark field contrast. Our method structures the beam with a single low-cost wire mesh that does not need precise alignment and relaxes the coherence requirement on the source. In addition, focusing polycapillary optics, which can be permanently attached to sources, are employed to allow for the use of high-power primary sources by increasing the phase signal after the focus. However, the coarseness of the mesh reduces the phase and dark field signal-to-noise ratio (SNR) compared with grating-based techniques, so optimization of the phase and dark-field SNR is an important consideration. Here, we consider the impact on the SNR of the distances between the mesh and the source and detector, and of x-ray tube voltages, to optimize the system.
- 30 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 035024
Open AccessOptimization of signal and noise in x-ray phase and dark field imaging with a wire mesh
Phase differences imparted by tissue are significantly larger than attenuation differences. In addition, small angle scatter from tissue microstructure can provide a dark field signal that is complementary to attenuation and phase. Unfortunately, the low spatial coherence of clinical sources reduces phase and dark field contrast. Our method structures the beam with a single low-cost wire mesh that does not need precise alignment and relaxes the coherence requirement on the source. In addition, focusing polycapillary optics, which can be permanently attached to sources, are employed to allow for the use of high-power primary sources by increasing the phase signal after the focus. However, the coarseness of the mesh reduces the phase and dark field signal-to-noise ratio (SNR) compared with grating-based techniques, so optimization of the phase and dark-field SNR is an important consideration. Here, we consider the impact on the SNR of the distances between the mesh and the source and detector, and of x-ray tube voltages, to optimize the system.