    Simulation of electromagnetic processes in the power supply of induction motors from underground substations

    by Dmytro Danylchenko, Sergii Shevchenko, Tetiana Divchuk, Liudmyla Skrupska

    The article considers the influence of cable line parameters on the power supply of induction motors from underground electrical substations. Ensuring reliable starting of induction motors from underground transformer substations is a critical task. The significant remoteness of consumers necessitates the use of long cable lines, which leads to deep voltage drops during direct start. The presence of nonlinear loads in the network that generate higher current and voltage harmonics further worsens energy performance by increasing total electrical and magnetic power losses in motors and transformers, accelerated thermal aging and insulation degradation in conditions of high humidity and aggressive environments, reduced dynamic stability of electric drives, and risks of process disruption. n this study, a comprehensive simulation of the power supply of induction motors from local and central underground electrical substations without and with the presence of higher voltage harmonics was carried out. An analysis of the voltage drop depending on the length and cross-section of the cable cores for the 1140 V network during direct start of an induction motor for capacities of 100–132 kW was performed, and an assessment of the influence of the harmonic composition of the supply voltage on the maximum (maximum) length of the network at which the conditions for normal direct start at the nominal torque of the induction motor are ensured was also performed. It has been established that in the presence of higher harmonics, the starting current increases, and therefore the voltage drop increases by an additional 4–6 %, which requires a forced reduction in the calculated network length by 15–20 %. It has been proven that to overcome these limitations, when powering an induction motor at distances of more than 1 km from an underground substation, it is necessary to abandon direct starting in favor of using soft starting devices (thyristor voltage regulators) or local vector frequency control systems.

  • Open Access

    Design of a scheme to protect transformers against bushing insulation damage, in order to modernize energy facilities

    by Oleksandr Sakhno, Serhii Shylo, Kostiantyn Odiyaka, Liudmyla Skrupska

    This study's object is a relay protection scheme against damage to transformers (autotransformers) and 35–750 kV shunt reactors as a result of bushing insulation breakdown. The study investigates the possibility of improving the efficiency of the relay protection of transformer equipment (TrE). The task relates to the widespread application of outdated TrE protection schemes and devices that account for their high cost, low operational efficiency, and may even harm TrE. This paper reports the results of investigating current signals from the measuring terminals of bushings and formulates basic requirements for implementing modernized protection schemes based on microprocessor monitoring unit. The proposed protection scheme modernization demonstrates improved operational characteristics: increased safety for personnel and equipment, reduced probability of false trips, decreased weight and dimensions, as well as cost. These characteristics were achieved by using a microprocessor device, reducing the length of measurement circuits, excluding matching transformers from the scheme, applying coupling devices with protection circuit. The effectiveness of using software filtering of current signals based on the discrete Fourier transform algorithm has been proposed and proven for excluding influence currents on the resulting unbalance vector. The inexpediency of accounting for all, except the 1st harmonic, components of insulation currents was demonstrated. The normalized value of the unbalance, while using full signals, was 14%, instead of 1.15%. The results could be used to manufacture and operate relay protection schemes and devices against 35–750 kV TrE damage caused by breakdown of bushing insulation to improve the reliability of power facilities

  • Open Access

    Improving the protection of high-voltage equipment with condenser-type insulation during technical condition monitoring under operating voltage

    by Oleksandr Sakhno, Kostiantyn Odiyaka, Liudmyla Skrupska

    The object of this study is condenser-type insulation of high-voltage electrical equipment and elements of its overvoltage protection circuits, in the case of breaking the cable to the diagnostic device of technical condition of insulation under operating voltage. The work reports a study on the overvoltage that can cause damage to high-voltage equipment with condenser-type insulation (bushings and instrument current transformers), equipped by hardware for monitoring the technical condition of insulation under operating voltage. Such overvoltage can occur as a result of damage of the cable from the test-tap of the device insulation and/or as a result of lightning and switching overvoltage on the buses of the switchgear. The task relates to insufficient attention and lack of requirements of regulatory documents to the insulation protection schemes of devices with an increase in the number of implementations of devices for monitoring the condition of insulation under operating voltage in recent years. The relevance of the issue is predetermined by war in Ukraine, when electric power facilities and the system as a whole are subject of military attacks, causing both physical destruction and provoking overvoltage and short circuits that affect equipment that has not been destroyed. The paper gives the results of modeling the overvoltage that may arise on the insulation test-tap of equipment with condenser-type insulation, when the cable to the monitoring device is damaged. The results of temperature tests of a complex protective resistor are presented. The use of a parallel resistor and a capacitor as the main protection elements has been justified. Such a scheme could limit the instantaneous overvoltage value for most devices at the level of no more than 1.6 kV, even without the use of additional protection elements, such as varistors or arresters, for example. A methodology and recommendations for selecting protective elements and checking the compliance have been devised, both under the nominal operating mode and in the presence of high-frequency overvoltage


  • Open Access

    Diagnostics of the technical state of high-voltage equipment under operating voltage

    by Oleksandr Sakhno, Liudmyla Skrupska, Kostiantyn Odiyaka, Volodymyr Vasylevskyi, Serhii Shylo

    The object of research is systems for online monitoring of the technical condition of oil-filled high-voltage electrical equipment during operation, which are used for automated diagnostics of the technical condition of equipment, resource forecasting and reducing of accidents. The work is devoted to finding opportunities to reduce the cost of online monitoring systems, taking into account the military situation in Ukraine. The problem is caused by the need to use such systems to increase personnel safety and reliability of power grids, reduce the risk of failures due to deterioration of the technical condition of equipment due to unforeseen resource depletion or accelerated development of hidden defects due to military actions (excessive short-circuit currents, overvoltage). But taking into account the fact that the restoration of the power structure of Ukraine takes place in conditions of limited financial resources, one of the important tasks is to use online monitoring systems with an optimal price/diagnostic capabilities ratio to ensure the required level of diagnostics with a reduction in material costs for such systems. The paper presents the results of an analytical study of the operation of online monitoring systems operated at various facilities over the past 20 years. The approach to diagnostics under operating voltage proposed in this study is aimed, first of all, at preventing emergency situations caused by the most frequent causes of accidents associated with: partial breakdown of capacitor insulation, increase in relative moisture saturation of transformer oil, appearance of dissolved gases in oil. The use of such an approach will increase the reliability of the power infrastructure and improve fault detection and preventive maintenance strategies while reducing the costs of organizing automated diagnostics in relation to “full-range” online monitoring systems of high-voltage equipment, which have been actively installed in Ukraine in recent years.