WYWeien Yu

Weien Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weien Yu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Class-Aware Supervised Contrastive Quadratic Neural Network for Imbalanced Bearing Fault Diagnosis

    by Wei-En Yu, Shiping Zhang, Jinwei Sun, Chenyu Li, Jing-Xiao Liao, Xiaoge Zhang

    Deep learning holds significant potential for bearing fault diagnosis; however, its effectiveness is often hindered by the pervasive issue of imbalanced data in industrial settings, where fault events are inherently rare. To address this widespread challenge, we propose the Class-Aware Supervised Contrastive Quadratic Neural Network (CCQNet), a novel framework combining a class-aware supervised contrastive learning scheme with a quadratic neural network backbone. Our approach introduces two key components to tackle data imbalance: a class-weighted contrastive loss and a logit adjusted cross-entropy loss, which work in tandem to ensure the model pays equal attention to both majority and minority classes. Additionally, we enhance feature extraction through a quadratic convolutional residual network, and provide a novel theoretical analysis linking the function of the quadratic neuron to the principle of autocorrelation in signal processing. Comprehensive experiments on both public and proprietary datasets demonstrate that CCQNet substantially outperforms state-of-the-art methods, particularly in scenarios with extreme data imbalance. The source code is publicly available at https://github.com/yuweien1220/CCQNet for evaluation and validation.


  • A Defocus-Robust Encoded Pattern for Simultaneous Absolute Positioning and Parallelism Evaluation in High-Magnification Microscopy

    by Weien Yu, Zijian Zhu, Chenyang Zhao

    Microscopy-based positioning techniques are applicable to precision manufacturing scenarios, such as semiconductor fabrication. High-magnification microscopic metrology (e.g., using a 100× objective) provides an extremely small pixel equivalent size, thereby offering a solid physical basis for achieving nanometer-level absolute positioning. However, the extremely shallow depth of field—typically a few hundred nanometers—makes spatially varying defocus, mainly induced by target–stage parallelism errors, a critical obstacle to robust large-range positioning. Existing encoded-pattern absolute positioning methods are therefore often demonstrated at low magnification, where defocus is less severe. This paper proposes an encoded-pattern method that enables both defocus-robust absolute positioning and in-situ installation parallelism evaluation under high magnification. For positioning, a sub-pixel edge-gradient scheme is used to estimate feature locations with reduced sensitivity to blur. For parallelism evaluation, the defocus-dependent blur magnitude is leveraged to quantify the target tilt. Experiments demonstrate a positioning resolution characterized by a standard deviation of 0.8 nm and an RMSE of 115.5 nm over a 3 mm × 3 mm range. Moreover, the proposed in-situ parallelism evaluation estimates the target tilt with a mean absolute error of 94.8 nm.

  • Phase Error Suppression in Periodic Patterns: A High Precision Method for Industrial Periodic Array Feature Extraction and Calibration

    by Weien Yu, Zijian Zhu, Qinghong Wan, Chenyang Zhao

    In industrial micro-vision systems, challenges like mounting parallelism, mechanical vibration, and thermal drift often cause frequent and non-uniform defocus, which degrades traditional corner detection and complicates camera calibration. While phase-based techniques are robust to defocus, their accuracy is limited by phase extraction errors. To overcome these issues, this paper combines Phase Error Suppression (PES) with full-field phase modeling for robust feature localization and accurate camera calibration of periodic array patterns in high-magnification scenarios. PES method enhances phase extraction and localization accuracy by optimizing parameters like windowing and filtering bandwidth, and full-field phase modeling enables precise radial distortion estimation from a single image. Experiments validate our method's accuracy and robustness under high defocus, demonstrating average errors of 120.59 nm for 90 μm displacement, 190 nm for periodic pattern dimension measurement. Its effective application in wafer solder joint pitch measurement yields an error of 491 nm, offering a reliable solution for high-precision micro-vision measurement and calibration.

  • An Investigation of the Planar 3-DOF Nanoscale Positioning Measurement Method Based on Cross-Encoded Pattern

    by Weien Yu, Zijian Zhu, Chenyang Zhao, Yueping Xi, Yang Yang, Qiaozhi Lei

    Precision positioning measurement technology based on micro-vision has important applications in high-end manufacturing fields such as semiconductors and machine tools. Currently, measurement methods based on pseudo-periodic patterns can break the limitations of periodic patterns and achieve a larger measurement range. However, existing methods have not considered the impact of defocus caused by large-range displacement or assembly misalignment on measurement accuracy. Additionally, the physical period of pseudo-periodic encoding units and the bit number are interdependent, which requires careful trade-offs when expanding the measurement range. To address these issues, this paper innovatively proposes a plane 3-DOF nanoscale positioning measurement method based on Adaptive Cross-Encoded Pattern (ACEP). By utilizing high-precision etching technology to ensure the center information of the patterns and encoding the size information of the pattern units, the proposed method mitigates the impact of defocus on measurement. A key advantage of the cross-encoded pattern design is its range scalability, which allows the pattern size to be adjusted to extend the measurement range. Experimental results show that the proposed method achieves a linear resolution of 20 nm and an angular resolution of 20 seconds, and the measurement accuracy remains stable over a 9 mm displacement range, demonstrating the method’s effectiveness and stability at nanoscale precision.