Biao He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Biao He has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dongliang Zhou
PLA Joint Logistics Support Force University of Engineering 1 , Chongqing 401331
1 shared publication - Huishu Liu
School of Petroleum Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
1 shared publication - Keyu Lin
PLA Joint Logistics Support Force University of Engineering, Chongqing 401311, China
1 shared publication - Run Li
PLA Joint Logistics Support Force University of Engineering, Chongqing 401311, China
1 shared publication - Tang Tang
PLA Joint Logistics Support Force University of Engineering, Chongqing 401311, China
1 shared publication - Xinsheng Jiang
PLA Joint Logistics Support Force University of Engineering, Chongqing 401311, China
1 shared publication
Latest Publications
- Open Access
Lightweight Fire and Smoke Detection with YOLO11: A Two-Benchmark, Multi-Seed Study of Wise-IoU and GhostConv
Vision-based fire and smoke detection must be both accurate and lightweight for edge cameras and unmanned aerial vehicles (UAVs). Most lightweight fire detectors, however, are validated on a single dataset from a single run, which leaves the accuracy–efficiency trade-off and its external validity only partially examined. Rather than a new state of the art, we take an evaluation-centered stance and study two lightweight operating points of YOLO11n: an accuracy-first variant (LFS-YOLO11-A) that adopts the Wise-IoU (WIoU) loss at no extra parameters, and a lightweight variant (LFS-YOLO11-B) that further adds GhostConv. Both are evaluated on the public D-Fire dataset, retrained on a second dataset (DFS) over eight seeds, and profiled across GPU/CPU under PyTorch and ONNX Runtime. LFS-YOLO11-A matches the baseline on D-Fire (mAP@0.5 0.760 versus 0.758), while LFS-YOLO11-B reduces parameters by 12.4% and computation by 11%, both exceeding 160 FPS end-to-end (batch = 1) on a desktop-class GPU. On DFS, WIoU yields a small, exploratory +0.6-point improvement (nominal paired p = 0.037; seed-sensitive, with a confidence interval lower bound near zero), whereas an apparent +6.1-point gain from an early, uncontrolled run proved to be train/test contamination introduced before the data pipeline was frozen, not a genuine effect. Frozen-pipeline, multi-seed, two-benchmark evaluation is therefore necessary to separate genuine effects from the artifacts of uncontrolled single runs in lightweight fire and smoke detection.
Open AccessLightweight Fire and Smoke Detection with YOLO11: A Two-Benchmark, Multi-Seed Study of Wise-IoU and GhostConv
Vision-based fire and smoke detection must be both accurate and lightweight for edge cameras and unmanned aerial vehicles (UAVs). Most lightweight fire detectors, however, are validated on a single dataset from a single run, which leaves the accuracy–efficiency trade-off and its external validity only partially examined. Rather than a new state of the art, we take an evaluation-centered stance and study two lightweight operating points of YOLO11n: an accuracy-first variant (LFS-YOLO11-A) that adopts the Wise-IoU (WIoU) loss at no extra parameters, and a lightweight variant (LFS-YOLO11-B) that further adds GhostConv. Both are evaluated on the public D-Fire dataset, retrained on a second dataset (DFS) over eight seeds, and profiled across GPU/CPU under PyTorch and ONNX Runtime. LFS-YOLO11-A matches the baseline on D-Fire (mAP@0.5 0.760 versus 0.758), while LFS-YOLO11-B reduces parameters by 12.4% and computation by 11%, both exceeding 160 FPS end-to-end (batch = 1) on a desktop-class GPU. On DFS, WIoU yields a small, exploratory +0.6-point improvement (nominal paired p = 0.037; seed-sensitive, with a confidence interval lower bound near zero), whereas an apparent +6.1-point gain from an early, uncontrolled run proved to be train/test contamination introduced before the data pipeline was frozen, not a genuine effect. Frozen-pipeline, multi-seed, two-benchmark evaluation is therefore necessary to separate genuine effects from the artifacts of uncontrolled single runs in lightweight fire and smoke detection.
- Open Access
A Self-Powered Density-Based Device for Automatic Mixed-Oil Cutting in Field Pipelines
Efficient oil transportation in field-deployed mobile pipelines is critical, but mixed-oil zones at interfaces reduce quality and increase waste, necessitating effective interface detection and cutting. Existing online densitometers, such as vibrating tube or high-accuracy magnetic suspension types, typically require external power, limiting their use in remote or emergency/temporary field operations. A self-powered device is presented that leverages gravitational force variations acting on a float to detect density changes and trigger automatic cutting. Validated with gasoline, diesel, kerosene, and water, it achieves a 10 kg/ resolution, deemed sufficient for functional batch separation in its target application, with switching times of 61–395 s for density differences (760–835 kg/). It supports 20–90% blending ratios, with a vent mitigating gas effects. The modular, robust, self-powered design suits emergency operations, offering a practical alternative to powered systems. Future work targets improved resolution and environmental testing.Open AccessA Self-Powered Density-Based Device for Automatic Mixed-Oil Cutting in Field Pipelines
Efficient oil transportation in field-deployed mobile pipelines is critical, but mixed-oil zones at interfaces reduce quality and increase waste, necessitating effective interface detection and cutting. Existing online densitometers, such as vibrating tube or high-accuracy magnetic suspension types, typically require external power, limiting their use in remote or emergency/temporary field operations. A self-powered device is presented that leverages gravitational force variations acting on a float to detect density changes and trigger automatic cutting. Validated with gasoline, diesel, kerosene, and water, it achieves a 10 kg/ resolution, deemed sufficient for functional batch separation in its target application, with switching times of 61–395 s for density differences (760–835 kg/). It supports 20–90% blending ratios, with a vent mitigating gas effects. The modular, robust, self-powered design suits emergency operations, offering a practical alternative to powered systems. Future work targets improved resolution and environmental testing.