TTTang Tang

Tang Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tang Tang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Combustion Characteristics of Soil Beds Soaked with Aviation Kerosene

    by Hui Chu, Xinsheng Jiang, Keyu Lin, Tang Tang, Shijie Zhu, Run Li

    Aviation kerosene leaked during airport storage, refueling, and ground-support operations can infiltrate soil pores and form oil-contaminated soil systems with combustion behavior different from that of free liquid pool fires. To clarify the regulating effect of soil physical properties on fire hazards, humus soil, lateritic soil, loess, and sandy soil were contaminated with 10, 30, 50, 70, and 90 g of No. 3 aviation kerosene and tested using a cone calorimeter under an external heat flux of 35 kW/m2. For humus soil, lateritic soil, and loess, the time to ignition generally ranged from 3.5 to 7.0 s. In contrast, sandy soil showed a distinctly delayed and nonmonotonic ignition response, with the longest time to ignition reaching approximately 18 s. Heat release increased with fuel loading, but the response varied markedly among soils. At 90 g, the peak HRR values of loess, humus soil, lateritic soil, and sandy soil were 1021, 964, 806, and 461 kW/m2, respectively, and their THR values were 380, 354, 356, and 334 MJ/m2. The mass-loss results further showed that MLR was not directly equivalent to effective heat release: sandy soil had a relatively high peak MLR of approximately 0.40 g/s at 90 g, but its HRR remained the lowest because part of the fuel loss was associated with downward migration or inefficient near-surface flaming. In contrast, loess combined the highest peak MLR, approximately 0.43 g/s, with the highest HRR, indicating efficient conversion of released fuel into flaming heat output. Smoke production was also substrate-dependent, with loess showing the strongest combined smoke hazard and humus soil exhibiting sustained smoke production. Overall, permeability, together with pore structure and fuel retention characteristics, was associated with the distribution of aviation kerosene between the near-surface region and deeper soil layers. These soil-dependent differences were reflected in ignition, heat release, mass loss, and smoke generation. Under the present test conditions, loess showed the highest combined fire hazard, followed by humus soil, lateritic soil, and sandy soil.

  • Open Access

    Lightweight Fire and Smoke Detection with YOLO11: A Two-Benchmark, Multi-Seed Study of Wise-IoU and GhostConv

    by Tang Tang, Xinsheng Jiang, Biao He, Dongliang Zhou, Run Li, Keyu Lin, Yunxiong Cai

    Vision-based fire and smoke detection must be both accurate and lightweight for edge cameras and unmanned aerial vehicles (UAVs). Most lightweight fire detectors, however, are validated on a single dataset from a single run, which leaves the accuracy–efficiency trade-off and its external validity only partially examined. Rather than a new state of the art, we take an evaluation-centered stance and study two lightweight operating points of YOLO11n: an accuracy-first variant (LFS-YOLO11-A) that adopts the Wise-IoU (WIoU) loss at no extra parameters, and a lightweight variant (LFS-YOLO11-B) that further adds GhostConv. Both are evaluated on the public D-Fire dataset, retrained on a second dataset (DFS) over eight seeds, and profiled across GPU/CPU under PyTorch and ONNX Runtime. LFS-YOLO11-A matches the baseline on D-Fire (mAP@0.5 0.760 versus 0.758), while LFS-YOLO11-B reduces parameters by 12.4% and computation by 11%, both exceeding 160 FPS end-to-end (batch = 1) on a desktop-class GPU. On DFS, WIoU yields a small, exploratory +0.6-point improvement (nominal paired p = 0.037; seed-sensitive, with a confidence interval lower bound near zero), whereas an apparent +6.1-point gain from an early, uncontrolled run proved to be train/test contamination introduced before the data pipeline was frozen, not a genuine effect. Frozen-pipeline, multi-seed, two-benchmark evaluation is therefore necessary to separate genuine effects from the artifacts of uncontrolled single runs in lightweight fire and smoke detection.


  • Open Access

    Vented Explosion Characteristics of Gasoline Vapor–Air Mixtures in Confined Spaces Under Different Ignition Modes

    by Run Li, Xinsheng Jiang, Shimao Wang, Guangqiang Yuan, Tang Tang, Keyu Lin, Sai Wang, Junjie Lin

    In a weakly constrained, confined space, four common ignition sources—electrical spark, open flame, tungsten filament, and electrochemical igniter—were employed to investigate how the ignition mode influences the overpressure and flame-propagation characteristics during the vented explosion of gasoline vapor. The results show that the explosion process can be divided into four stages, featuring three typical overpressure peaks. The flame velocity exhibits two pronounced accelerations: one upon rupture of the vent membrane and another when the flame reaches the vent opening. Among the ignition sources tested, the electric spark produced the most severe destructive effects associated with overpressure, while the electrochemical igniter yielded the fastest flame propagation, and the tungsten filament ignition generated the longest external flame, constituting the greatest external fire threat. Explosions initiated by the tungsten filament and electrochemical igniter experience flame instability at the outset, induced by disturbances from the ignition source itself.

  • Experimental investigation on the vibration response of an inclined near-wall flexible pipe span conveying different internal flows

    by Hongjun Zhu, Zhuohong Wang, Tang Tang, Mahbub Alam, Tongming Zhou

    This paper reports the experimental results of the vortex-induced vibration (VIV) and pipe-wall impact of an inclined near-wall flexible pipe transporting three representative internal flows with oblique angle (θ) ranging from 0° to 45°. The flexible pipe with an aspect ratio of 57 was fixed at both ends. The tests were performed in a recirculation water flume in the reduced velocity range of Ur = 7.92–23.92 using the non-intrusive optical measurement. The experimental results indicate that the existence of internal flow causes the tilt of the peaks of root-mean-squared (RMS) amplitude toward the downstream of internal flow. Nevertheless, with increasing θ, the peaks of RMS amplitude tilt to the upstream of internal flow. The mode competition of the pipe conveying gas flow is the weakest, but it is the most sensitive to θ. In contrast, the most intense mode competitions are observed in the pipe conveying gas–liquid flow and the pipe conveying liquid flow for the in-line and cross-flow directions, respectively. Five pipe-wall impact patterns are identified based on the impact position and frequency, and the partition of wall-impact pattern is provided in the s/L–Urn diagram. The impact position undergoes spatial transfer with the change of θ, especially for the pipe conveying gas flow. By comprehensive consideration of the spatial-temporal evolution of VIV response and impacting segments, the independence principle is invalid in predicting the VIV of near-wall flexible pipe span conveying internal flow.