Yishu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yishu Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bizhao Wu
Key Laboratory of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology, Harbin 150090, China
1 shared publication - Han Wang
School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China
1 shared publication - Lin Zhao
School of Civil Engineering, Heilongjiang University, Harbin 150080, China
1 shared publication - Wei Wang
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
1 shared publication - Zhenggang Cao
Key Laboratory of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology, Harbin 150090, China
1 shared publication
Latest Publications
- Open Access
Modified Constitutive Model and Practical Calibration Method for Constructional 7075-T6 Aluminum Alloy
Recently, high-strength 7075-T6 aluminum alloy has demonstrated promising application prospects in large-span spatial structures given its exceptional mechanical properties. However, the classical Ramberg–Osgood (R–O) constitutive model cannot accurately predict the mechanical behavior of 7075-T6 aluminum alloy in the large-strain stage, compromising the structural reliability of designs. Herein, the full-range stress–strain curves of 7075-T6 aluminum alloy were investigated through tensile tests. Mechanical property indices were obtained, and the classical R–O model was calibrated for 7075-T6 aluminum alloy. Furthermore, an improved R–O model based on piecewise functions was proposed to address the significant prediction errors under large-strain conditions (ε > 0.015). Compared with the classical R–O model, the modified model exhibited a reduction of over 75% in stress–strain curve deviation. Moreover, an approximate value method only based on nonproportional extension strength and elastic modulus was proposed for the calibration of the modified model, considerably enhancing the engineering practicality of the modified constitutive model.
Open AccessModified Constitutive Model and Practical Calibration Method for Constructional 7075-T6 Aluminum Alloy
Recently, high-strength 7075-T6 aluminum alloy has demonstrated promising application prospects in large-span spatial structures given its exceptional mechanical properties. However, the classical Ramberg–Osgood (R–O) constitutive model cannot accurately predict the mechanical behavior of 7075-T6 aluminum alloy in the large-strain stage, compromising the structural reliability of designs. Herein, the full-range stress–strain curves of 7075-T6 aluminum alloy were investigated through tensile tests. Mechanical property indices were obtained, and the classical R–O model was calibrated for 7075-T6 aluminum alloy. Furthermore, an improved R–O model based on piecewise functions was proposed to address the significant prediction errors under large-strain conditions (ε > 0.015). Compared with the classical R–O model, the modified model exhibited a reduction of over 75% in stress–strain curve deviation. Moreover, an approximate value method only based on nonproportional extension strength and elastic modulus was proposed for the calibration of the modified model, considerably enhancing the engineering practicality of the modified constitutive model.
- Open Access
Performance Improvement of Steel Fiber Reinforced High-Performance Concrete Cured by Electric-Induced Heating Under Negative Temperature by Mix Proportion Optimization
To address the insufficient early strength development of steel-fiber-reinforced high-performance concrete (SF-HPC) under subzero temperatures, this study proposes an electric-induced heating curing method for SF-HPC fabrication at −20 °C. The effects of mix parameters, including steel fiber content, water-to-binder ratio, silica fume dosage, and fine aggregate gradation, on the curing temperature and mechanical properties of SF-HPC were systematically investigated. The optimal mix proportion was identified through the curing temperature and compressive strength development for the specimens. Results revealed that compressive strength initially increased and then decreased with higher silica fume content and fine aggregate replacement ratios, while increased water-to-binder ratios positively influenced curing efficiency and strength development. The optimal mix comprised 2.0 vol% steel fibers, a water-to-binder ratio of 0.22, 20% silica fume, and 60% fine aggregate replacement. Further, comparative analyses of electric-induced heating curing, room-temperature curing, and high-temperature steam curing revealed that electric-induced heating curing can promote the strength formation of SF-HPC in a negative-temperature environment. Microstructural characterization via BET analysis demonstrated that electric-induced heating curing refined the pore structure of SF-HPC. These findings highlight the benefits of electric-induced heating as an efficient strategy for fabricating SF-HPC in cold climates, providing theoretical and practical insights for winter construction.
Open AccessPerformance Improvement of Steel Fiber Reinforced High-Performance Concrete Cured by Electric-Induced Heating Under Negative Temperature by Mix Proportion Optimization
To address the insufficient early strength development of steel-fiber-reinforced high-performance concrete (SF-HPC) under subzero temperatures, this study proposes an electric-induced heating curing method for SF-HPC fabrication at −20 °C. The effects of mix parameters, including steel fiber content, water-to-binder ratio, silica fume dosage, and fine aggregate gradation, on the curing temperature and mechanical properties of SF-HPC were systematically investigated. The optimal mix proportion was identified through the curing temperature and compressive strength development for the specimens. Results revealed that compressive strength initially increased and then decreased with higher silica fume content and fine aggregate replacement ratios, while increased water-to-binder ratios positively influenced curing efficiency and strength development. The optimal mix comprised 2.0 vol% steel fibers, a water-to-binder ratio of 0.22, 20% silica fume, and 60% fine aggregate replacement. Further, comparative analyses of electric-induced heating curing, room-temperature curing, and high-temperature steam curing revealed that electric-induced heating curing can promote the strength formation of SF-HPC in a negative-temperature environment. Microstructural characterization via BET analysis demonstrated that electric-induced heating curing refined the pore structure of SF-HPC. These findings highlight the benefits of electric-induced heating as an efficient strategy for fabricating SF-HPC in cold climates, providing theoretical and practical insights for winter construction.