Daeho Jeong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daeho Jeong has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- An-Giang Nguyen
Center for Environmental Intelligence, VinUniversity, Hanoi 100000, Vietnam
1 shared publication - Bok Hyun Ka
Battery Diagnosis Lab, Samsung SDI, Suwon 16678, Republic of Korea
1 shared publication - Chan-Jin Park
Department of Materials Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, South Korea
1 shared publication - Chan-Woo Park
Chonnam National University
1 shared publication - Eui-Chol Shin
Chonnam National University
1 shared publication - Gooreum Kim
Center for Nanomedicine
1 shared publication
Latest Publications
- 21 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (4) , e11700
Magnetically Guided Flexible Bioelectronic Probe for Single‐Cell Recordings in Multi‐Scale Biosystems
Bioelectronic systems enable label‐free monitoring and modulation of cellular activity, providing essential tools for neuroscience and biomedical applications. Nevertheless, many current interfaces are structurally static and lack active positioning capabilities, limiting their adaptability in spatially complex environments. Here, Mag‐N‐Probe (Magnetically guided Neural‐interfacing Probe), a flexible and magnetically actuated bioelectronic system is introduced that enables remote, real‐time motion control with sub‐micrometer precision and centimeter‐scale navigation. The system incorporates ferromagnetic nanoparticles within a pliable mesh framework and utilizes both torque‐ and gradient force‐driven actuation for controlled navigation in confined spaces. This capability permits the repeated targeting of individual neurons for compartment‐specific electrophysiological recordings and conformal integration with brain organoids for reliable, multi‐channel signal acquisition. By combining magnetic actuation with flexible bioelectronics, Mag‐N‐Probe provides a versatile and scalable solution for adaptive neural interfacing, applicable to both single‐cell studies and 3D tissue environments, thus supporting a wide range of in vitro studies and promising prospects for minimally invasive in vivo applications.
- 21 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (4) , e11700
Magnetically Guided Flexible Bioelectronic Probe for Single‐Cell Recordings in Multi‐Scale Biosystems
Bioelectronic systems enable label‐free monitoring and modulation of cellular activity, providing essential tools for neuroscience and biomedical applications. Nevertheless, many current interfaces are structurally static and lack active positioning capabilities, limiting their adaptability in spatially complex environments. Here, Mag‐N‐Probe (Magnetically guided Neural‐interfacing Probe), a flexible and magnetically actuated bioelectronic system is introduced that enables remote, real‐time motion control with sub‐micrometer precision and centimeter‐scale navigation. The system incorporates ferromagnetic nanoparticles within a pliable mesh framework and utilizes both torque‐ and gradient force‐driven actuation for controlled navigation in confined spaces. This capability permits the repeated targeting of individual neurons for compartment‐specific electrophysiological recordings and conformal integration with brain organoids for reliable, multi‐channel signal acquisition. By combining magnetic actuation with flexible bioelectronics, Mag‐N‐Probe provides a versatile and scalable solution for adaptive neural interfacing, applicable to both single‐cell studies and 3D tissue environments, thus supporting a wide range of in vitro studies and promising prospects for minimally invasive in vivo applications.
- Open Access
GITT Limitations and EIS Insights into Kinetics of NMC622
Conventional applications of the Galvanostatic Intermittent Titration Technique (GITT) and EIS for estimating chemical diffusivity in battery electrodes face issues such as insufficient relaxation time to reach equilibrium, excessively long pulse durations that violate the short-time diffusion assumption, and the assumption of sequential electrode reaction and diffusion processes. In this work, a quasi-equilibrium criterion of 0.1 mV h−1 was applied to NMC622 electrodes, yielding 8–9 h relaxations below 3.8 V, but above 3.8 V, voltage decayed linearly and indefinitely, even upon discharging titration, showing unusual nonmonotonic relaxation behavior. The initial 36-s transients of a 10-min galvanostatic pulse and diffusion impedance in series with the electrode reaction yielded consistent diffusivity values. However, solid-state diffusion in spherical active particles within porous electrodes, where ambipolar diffusion occurs in the pore electrolyte with , requires a physics-based three-rail transmission line model (TLM). The corrected diffusivity may be three to four times higher. An analytic two-rail TLM approximating the three-rail numerical model was applied to temperature- and frequency-dependent EIS data. This approach mitigates parameter ambiguity and unphysical correlations in EIS. Physics-based EIS enables the identification of multistep energetics and the diagnosis of performance and degradation mechanisms.Open AccessGITT Limitations and EIS Insights into Kinetics of NMC622
Conventional applications of the Galvanostatic Intermittent Titration Technique (GITT) and EIS for estimating chemical diffusivity in battery electrodes face issues such as insufficient relaxation time to reach equilibrium, excessively long pulse durations that violate the short-time diffusion assumption, and the assumption of sequential electrode reaction and diffusion processes. In this work, a quasi-equilibrium criterion of 0.1 mV h−1 was applied to NMC622 electrodes, yielding 8–9 h relaxations below 3.8 V, but above 3.8 V, voltage decayed linearly and indefinitely, even upon discharging titration, showing unusual nonmonotonic relaxation behavior. The initial 36-s transients of a 10-min galvanostatic pulse and diffusion impedance in series with the electrode reaction yielded consistent diffusivity values. However, solid-state diffusion in spherical active particles within porous electrodes, where ambipolar diffusion occurs in the pore electrolyte with , requires a physics-based three-rail transmission line model (TLM). The corrected diffusivity may be three to four times higher. An analytic two-rail TLM approximating the three-rail numerical model was applied to temperature- and frequency-dependent EIS data. This approach mitigates parameter ambiguity and unphysical correlations in EIS. Physics-based EIS enables the identification of multistep energetics and the diagnosis of performance and degradation mechanisms. - 1 December 2017
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 806, 123-129
Label-free impedimetric glycosensor based on β-galactose-functionalized gold electrode for the determination of cholera toxin
- 1 December 2017
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 806, 123-129
Label-free impedimetric glycosensor based on β-galactose-functionalized gold electrode for the determination of cholera toxin