Gooreum Kim
Gooreum Kim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Hyun Lee
Graduate Program of Nano Biomedical Engineering (NanoBME) Advanced Science Institute Yonsei University Seoul 03722 Republic of Korea
2 shared publications - Daeho Jeong
Center for Nanomedicine Institute for Basic Science (IBS) Yonsei University Seoul 03722 Republic of Korea
1 shared publication - Heehun Kim
Graduate Program of Nano Biomedical Engineering (NanoBME) Advanced Science Institute Yonsei University Seoul 03722 Republic of Korea
1 shared publication - Jinho Jang
Graduate Program of Nano Biomedical Engineering (NanoBME) Advanced Science Institute Yonsei University Seoul 03722 Republic of Korea
1 shared publication Jinwoo Cheon
Graduate Program of Nano Biomedical Engineering (NanoBME) Advanced Science Institute Yonsei University Seoul 03722 Republic of Korea
1 shared publication- Jinwoo Cheon
Center for Nanomedicine, Institute for Basic Science (IBS), Seoul, Republic of Korea
1 shared publication
Latest Publications
- 25 November 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (49) , 66450-66459
Corrugated-Surface Goethite Nanoparticles with Reduced Magnetization and Increased Surface Area for Enhanced T 1 MRI Contrast Effect
Gadolinium (Gd)-based MRI contrast agents are commonly used for T1 imaging but raise safety concerns, including nephrogenic systemic fibrosis and tissue buildup. Conventional iron oxide nanoparticles (IONPs), seen as safer options, often have residual magnetization, causing T2 effects and negative contrast, complicating interpretation. These limitations highlight the need for safer, positive-contrast agents with optimized relaxivity profiles. Here, we report the development of corrugated-surface iron oxide (COSIO) nanoparticles via a two-step seed-conversion strategy involving Fe3S4 intermediates and subsequent oxidative transformation into goethite (α-FeO(OH)). Unlike traditional ultrasmall IONPs, COSIO exhibits substantially reduced magnetization and a corrugated morphology that enhances water-accessible surface area, helping proton exchange. These two effects lower transverse relaxivity (r2) and increase longitudinal relaxivity (r1), respectively, leading to favorable T1 imaging performance. In vivo studies demonstrate that COSIO outperforms a clinical Gd-based contrast agent, Magnevist, in both tumor and cerebral vascular imaging, providing prolonged contrast retention and sharp vascular delineation without nonspecific enhancement. These findings highlight the significance of nanoscale morphological control in developing effective iron-based T1 MRI contrast agents.
- 25 November 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (49) , 66450-66459
Corrugated-Surface Goethite Nanoparticles with Reduced Magnetization and Increased Surface Area for Enhanced T 1 MRI Contrast Effect
Gadolinium (Gd)-based MRI contrast agents are commonly used for T1 imaging but raise safety concerns, including nephrogenic systemic fibrosis and tissue buildup. Conventional iron oxide nanoparticles (IONPs), seen as safer options, often have residual magnetization, causing T2 effects and negative contrast, complicating interpretation. These limitations highlight the need for safer, positive-contrast agents with optimized relaxivity profiles. Here, we report the development of corrugated-surface iron oxide (COSIO) nanoparticles via a two-step seed-conversion strategy involving Fe3S4 intermediates and subsequent oxidative transformation into goethite (α-FeO(OH)). Unlike traditional ultrasmall IONPs, COSIO exhibits substantially reduced magnetization and a corrugated morphology that enhances water-accessible surface area, helping proton exchange. These two effects lower transverse relaxivity (r2) and increase longitudinal relaxivity (r1), respectively, leading to favorable T1 imaging performance. In vivo studies demonstrate that COSIO outperforms a clinical Gd-based contrast agent, Magnevist, in both tumor and cerebral vascular imaging, providing prolonged contrast retention and sharp vascular delineation without nonspecific enhancement. These findings highlight the significance of nanoscale morphological control in developing effective iron-based T1 MRI contrast agents.
- 21 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (4) , e11700
Magnetically Guided Flexible Bioelectronic Probe for Single‐Cell Recordings in Multi‐Scale Biosystems
Bioelectronic systems enable label‐free monitoring and modulation of cellular activity, providing essential tools for neuroscience and biomedical applications. Nevertheless, many current interfaces are structurally static and lack active positioning capabilities, limiting their adaptability in spatially complex environments. Here, Mag‐N‐Probe (Magnetically guided Neural‐interfacing Probe), a flexible and magnetically actuated bioelectronic system is introduced that enables remote, real‐time motion control with sub‐micrometer precision and centimeter‐scale navigation. The system incorporates ferromagnetic nanoparticles within a pliable mesh framework and utilizes both torque‐ and gradient force‐driven actuation for controlled navigation in confined spaces. This capability permits the repeated targeting of individual neurons for compartment‐specific electrophysiological recordings and conformal integration with brain organoids for reliable, multi‐channel signal acquisition. By combining magnetic actuation with flexible bioelectronics, Mag‐N‐Probe provides a versatile and scalable solution for adaptive neural interfacing, applicable to both single‐cell studies and 3D tissue environments, thus supporting a wide range of in vitro studies and promising prospects for minimally invasive in vivo applications.
- 21 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (4) , e11700
Magnetically Guided Flexible Bioelectronic Probe for Single‐Cell Recordings in Multi‐Scale Biosystems
Bioelectronic systems enable label‐free monitoring and modulation of cellular activity, providing essential tools for neuroscience and biomedical applications. Nevertheless, many current interfaces are structurally static and lack active positioning capabilities, limiting their adaptability in spatially complex environments. Here, Mag‐N‐Probe (Magnetically guided Neural‐interfacing Probe), a flexible and magnetically actuated bioelectronic system is introduced that enables remote, real‐time motion control with sub‐micrometer precision and centimeter‐scale navigation. The system incorporates ferromagnetic nanoparticles within a pliable mesh framework and utilizes both torque‐ and gradient force‐driven actuation for controlled navigation in confined spaces. This capability permits the repeated targeting of individual neurons for compartment‐specific electrophysiological recordings and conformal integration with brain organoids for reliable, multi‐channel signal acquisition. By combining magnetic actuation with flexible bioelectronics, Mag‐N‐Probe provides a versatile and scalable solution for adaptive neural interfacing, applicable to both single‐cell studies and 3D tissue environments, thus supporting a wide range of in vitro studies and promising prospects for minimally invasive in vivo applications.