Chao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chao Wu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jianping Shi
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210046, China
3 shared publications - Fuyin Wei
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210023, China
1 shared publication - Hongkai Yang
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210023, China
1 shared publication - Jiquan Yang
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210046, China
1 shared publication - Qian Zhu
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210046, China
1 shared publication - Ruiquan Hu
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210046, China
1 shared publication
Latest Publications
- Open Access
A Hybrid Microchannel Heat Sink Featuring Micro Pin-Fins with Secondary Channels for Hotspot Suppression
Non-uniform heat flux in high-power electronic devices can induce local hotspots. To address hotspot thermal management, a hybrid microchannel heat sink featuring micro pin-fins with secondary channels (MPSCs) is proposed. Straight microchannels are used in the low-heat-flux region, while staggered pin-fins are arranged in the central hotspot region. Five models are considered: solid pin-fins without secondary channels (M1) and pin-fins with one-, three-, four-, and six-directional secondary channels (M2–M5). Over Re = 200–800, the thermal resistance of M3 is reduced by up to 43.3% compared with the SPMS, and the maximum PEC reaches 1.178. MPSC structures achieve better cooling at lower pumping power. At similar pumping power, the thermal resistance of M3 is 36.8% lower than the minimum value attainable by the SPMS. However, the marginal reduction in thermal resistance gradually weakens as the pumping power increases. The effects of hotspot heat flux and relative pin-fin height are investigated. MPSCs can withstand higher heat loads. Under a hotspot heat flux of 800 W/cm2, the maximum temperature of M3 remains below the safety threshold. Relative pin-fin height has a coupled effect on the thermal–hydraulic performance. At Re = 800, the PEC of M3 at RPH = 0.9 is about 2.8% higher than that at RPH = 1.0, and a PEC fitting equation is developed. The results show that the hybrid micro pin-fin heat sink with secondary channels disrupts the thermal boundary layer through internal flow diversion and local disturbance, thereby balancing hotspot suppression and pressure drop control. This design provides a reference for hotspot thermal management and thermal–hydraulic optimization of microchannel heat sinks.
Open AccessA Hybrid Microchannel Heat Sink Featuring Micro Pin-Fins with Secondary Channels for Hotspot Suppression
Non-uniform heat flux in high-power electronic devices can induce local hotspots. To address hotspot thermal management, a hybrid microchannel heat sink featuring micro pin-fins with secondary channels (MPSCs) is proposed. Straight microchannels are used in the low-heat-flux region, while staggered pin-fins are arranged in the central hotspot region. Five models are considered: solid pin-fins without secondary channels (M1) and pin-fins with one-, three-, four-, and six-directional secondary channels (M2–M5). Over Re = 200–800, the thermal resistance of M3 is reduced by up to 43.3% compared with the SPMS, and the maximum PEC reaches 1.178. MPSC structures achieve better cooling at lower pumping power. At similar pumping power, the thermal resistance of M3 is 36.8% lower than the minimum value attainable by the SPMS. However, the marginal reduction in thermal resistance gradually weakens as the pumping power increases. The effects of hotspot heat flux and relative pin-fin height are investigated. MPSCs can withstand higher heat loads. Under a hotspot heat flux of 800 W/cm2, the maximum temperature of M3 remains below the safety threshold. Relative pin-fin height has a coupled effect on the thermal–hydraulic performance. At Re = 800, the PEC of M3 at RPH = 0.9 is about 2.8% higher than that at RPH = 1.0, and a PEC fitting equation is developed. The results show that the hybrid micro pin-fin heat sink with secondary channels disrupts the thermal boundary layer through internal flow diversion and local disturbance, thereby balancing hotspot suppression and pressure drop control. This design provides a reference for hotspot thermal management and thermal–hydraulic optimization of microchannel heat sinks.
- Open Access
Flexible Receiver Antenna Prepared Based on Conformal Printing and Its Wearable System
Microwave energy is ideal for wearable devices due to its stable wireless power transfer capabilities. However, rigid receiving antennas in conventional RF energy harvesters compromise wearability. This study presents a wearable system using a flexible dual-band antenna (915 MHz/2.45 GHz) fabricated via conformal 3D printing on arm-mimicking curvatures, minimizing bending-induced performance loss. A hybrid microstrip–lumped element rectifier circuit enhances energy conversion efficiency. Tested with commercial 915 MHz transmitters and Wi-Fi routers, the system consistently delivers 3.27–3.31 V within an operational range, enabling continuous power supply for real-time physiological monitoring (e.g., pulse detection) and data transmission. This work demonstrates a practical solution for sustainable energy harvesting in flexible wearables.
Open AccessFlexible Receiver Antenna Prepared Based on Conformal Printing and Its Wearable System
Microwave energy is ideal for wearable devices due to its stable wireless power transfer capabilities. However, rigid receiving antennas in conventional RF energy harvesters compromise wearability. This study presents a wearable system using a flexible dual-band antenna (915 MHz/2.45 GHz) fabricated via conformal 3D printing on arm-mimicking curvatures, minimizing bending-induced performance loss. A hybrid microstrip–lumped element rectifier circuit enhances energy conversion efficiency. Tested with commercial 915 MHz transmitters and Wi-Fi routers, the system consistently delivers 3.27–3.31 V within an operational range, enabling continuous power supply for real-time physiological monitoring (e.g., pulse detection) and data transmission. This work demonstrates a practical solution for sustainable energy harvesting in flexible wearables.
- Open Access
Numerical Simulation and Optimized Field-Driven Design of Triple Periodic Minimal Surface Structure Liquid-Cooling Radiator
This work investigates the design of liquid-cooled heat sinks for IGBT modules via optimizing the Triple Periodic Minimal Surface (TPMS) structure. The performance of heat sinks with different porosity TPMS structures was compared through the finite element simulation software Fluent. The results indicate that smaller porosity is conducive to improving the heat dissipation efficiency, but the difference in pressure between the entrance and exit increases. The field-driven design method is further adopted to adjust the porosity according to the temperature field distribution, and the TPMS channel structures were optimized by nTopology software. The results show that the optimized Schwarz P, Gyroid, and Diamond structures have a comparable effect on reducing the maximum surface temperature as that of TPMS structures with uniform porosity; however, the differential pressure at the inlet and outlet decreased remarkably by 94.8%, 90.8%, and 88.9%, respectively, compared to the structure with a uniform porosity of 0.32. The Nusselt numbers of the optimized Gyroid and Diamond structures increased by 19.2% and 12.3%, respectively, compared to their structures with a uniform porosity of 0.84. This study illustrates the advantages of the field-driven design in enhancing the heat dissipation and reducing pressure loss, which provides an effective design solution for the heat dissipation of IGBT modules.
Open AccessNumerical Simulation and Optimized Field-Driven Design of Triple Periodic Minimal Surface Structure Liquid-Cooling Radiator
This work investigates the design of liquid-cooled heat sinks for IGBT modules via optimizing the Triple Periodic Minimal Surface (TPMS) structure. The performance of heat sinks with different porosity TPMS structures was compared through the finite element simulation software Fluent. The results indicate that smaller porosity is conducive to improving the heat dissipation efficiency, but the difference in pressure between the entrance and exit increases. The field-driven design method is further adopted to adjust the porosity according to the temperature field distribution, and the TPMS channel structures were optimized by nTopology software. The results show that the optimized Schwarz P, Gyroid, and Diamond structures have a comparable effect on reducing the maximum surface temperature as that of TPMS structures with uniform porosity; however, the differential pressure at the inlet and outlet decreased remarkably by 94.8%, 90.8%, and 88.9%, respectively, compared to the structure with a uniform porosity of 0.32. The Nusselt numbers of the optimized Gyroid and Diamond structures increased by 19.2% and 12.3%, respectively, compared to their structures with a uniform porosity of 0.84. This study illustrates the advantages of the field-driven design in enhancing the heat dissipation and reducing pressure loss, which provides an effective design solution for the heat dissipation of IGBT modules.