Vaibhav Nougain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vaibhav Nougain has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandra Lekić
Delft University of Technology
2 shared publications - Aditya Shekhar
Delft University of Technology
1 shared publication - Adria Junyent-Ferre
Imperial College London
1 shared publication - Joan-Marc Rodriguez-Bernuz
Escola Tècnica Superior d’Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (UPC), 08028 Barcelona, Spain
1 shared publication - Milovan Majstorović
School of Electrical Engineering, University of Belgrade, Belgrade, Serbia
1 shared publication - Naajein Cherat
Department of Electrical Sustainable Energy Delft University of Technology Delft The Netherlands
1 shared publication
Latest Publications
- Open Access
Adaptive Single-Terminal Fault Location for DC Microgrids
Identifying faulty lines and their accurate location is key for rapidly restoring distribution systems. This will become a greater challenge as the penetration of power electronics increases, and contingencies are seen across larger areas. This paper proposes a single terminal methodology (i.e., no communication involved) that is robust to variations of key parameters (e.g., sampling frequency, system parameters, etc.) and performs particularly well for low resistance faults that constitute the majority of faults in low voltage DC systems. The proposed method uses local measurements to estimate the current caused by the other terminals affected by the contingency. This mimics the strategy followed by double terminal methods that require communications and decouples the accuracy of the methodology from the fault resistance. The algorithm takes consecutive voltage and current samples, including the estimated current of the other terminal, into the analysis. This mathematical methodology results in a better accuracy than other single-terminal approaches found in the literature. The robustness of the proposed strategy against different fault resistances and locations is demonstrated using MATLAB simulations.
Open AccessAdaptive Single-Terminal Fault Location for DC Microgrids
Identifying faulty lines and their accurate location is key for rapidly restoring distribution systems. This will become a greater challenge as the penetration of power electronics increases, and contingencies are seen across larger areas. This paper proposes a single terminal methodology (i.e., no communication involved) that is robust to variations of key parameters (e.g., sampling frequency, system parameters, etc.) and performs particularly well for low resistance faults that constitute the majority of faults in low voltage DC systems. The proposed method uses local measurements to estimate the current caused by the other terminals affected by the contingency. This mimics the strategy followed by double terminal methods that require communications and decouples the accuracy of the methodology from the fault resistance. The algorithm takes consecutive voltage and current samples, including the estimated current of the other terminal, into the analysis. This mathematical methodology results in a better accuracy than other single-terminal approaches found in the literature. The robustness of the proposed strategy against different fault resistances and locations is demonstrated using MATLAB simulations.
- Open Access
Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults
Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a $\pm$525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).
Open AccessEvent-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults
Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a $\pm$525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).