S. Wilde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
S. Wilde has a total of 338 co-authors. Here are the top co-authors by number of shared publications:
A. Iverson
Colorado State University
4 shared publicationsA. Karelin
Kurchatov Institute
4 shared publicationsA. Kuchenkov
Kurchatov Institute
4 shared publicationsA. Larson
University of South Dakota
4 shared publicationsA. Nolan
University of Massachusetts, Amherst
4 shared publications- Brian Mong
SLAC National Accelerator Laboratory
4 shared publications
Latest Publications
- 17 November 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (5)
nEXO radioassay program
- 17 November 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (5)
nEXO radioassay program
- Open Access
Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments
The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.
Open AccessUltra-pure Nickel for Structural Components of Low-Radioactivity Instruments
The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.
- Open Access
- 29 January 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (2) , 355-359
Multicusp ion source with external rf antenna for production of protons
Proton beams are needed in neutral-beam injection for diagnostic development of an internal magnetic field measurement. High proton fraction, low axial energy spread, current density in excess of and a parallel ion beam with cw operation are the requirements for the ion source/extraction system. A multicusp-type ion source with an external rf antenna was constructed at Lawrence Berkeley National Laboratory. A proton fraction of 85% and proton current density of were achieved at 1.8 kW of rf power. Plasma parameters were measured with a rf compensated Langmuir probe.- 29 January 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (2) , 355-359
Open AccessMulticusp ion source with external rf antenna for production of protons
Proton beams are needed in neutral-beam injection for diagnostic development of an internal magnetic field measurement. High proton fraction, low axial energy spread, current density in excess of and a parallel ion beam with cw operation are the requirements for the ion source/extraction system. A multicusp-type ion source with an external rf antenna was constructed at Lawrence Berkeley National Laboratory. A proton fraction of 85% and proton current density of were achieved at 1.8 kW of rf power. Plasma parameters were measured with a rf compensated Langmuir probe.