TUTran Ha Uyen
Tran Ha Uyen
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tran Ha Uyen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hoang Thai Long
Department of Chemisstry, University of Sciences, Hue University, 77 Nguyen Hue St., Hue, Vietnam
1 shared publication Le Quoc Hung
Institute of Chemistry, Vietnam Academy of Science and Technology, Ha Noi 100000, Vietnam
1 shared publication- Nguyen Hai Phong
University of Sciences, Hue University, Hue City, Vietnam
1 shared publication Nguyen Nhi Phuong
University of Sciences, Hue University, Hue 530000, Vietnam
1 shared publication- Nguyen Thi Hue
Vietnam Academy of Science and Technology (VAST)
1 shared publication Nguyen Van Hop
University of Sciences, Hue University, Hue 530000, Vietnam
1 shared publication
Latest Publications
- Open Access
- 14 May 2020
- Published by Wiley in Journal of Environmental and Public Health
- Vol. 2020, 1-15
Determination of Chromium in Natural Water by Adsorptive Stripping Voltammetry UsingIn SituBismuth Film Electrode
Development of adsorptive stripping voltammetry (AdSV) combined within situprepared bismuth film electrode (in situBiFE) on glassy carbon disk surface using diethylenetriamine pentaacetic acid (DTPA) as a complexing agent andas a catalyst to determine the trace amount of chromium (VI) is demonstrated. According to this method, in the preconcentration step atEdep = −800 mV, the bismuth film is coated on the surface of glassy carbon electrodes simultaneously with the adsorption of complexes Cr(III)-DTPA. In addition to the influencing factors, the stripping voltammetry performance factors such as deposition potential, deposition time, equilibration time, cleaning potential, cleaning time, and technical parameters of differential pulse and square wave voltammetries have been investigated, and the influence of Cr(III), Co(II), Ni(II), Ca(II), Fe(III),, Cl−, and Triton X has also been investigated. This method gained good repeatability with RSD <4% (n = 9) for the differential pulse adsorptive stripping voltammetry (DP-AdSV) and RSD < 3% (n = 7) for the square wave adsorptive stripping voltammetry (SqW-AdSV), and low limit of detection: LOD = 12.10−9 M ≈ 0.6 ppb (at a deposition potential (Edep) of −800 mV and the deposition time (tdep) of 50 s) and LOD = 2.10−9 M ≈ 0.1 ppb (atEdep = −800 mV andtdep = 160 s) for the DP-AdSV and SqW-AdSV, respectively. This method has been successfully applied to analyze chromium in natural water.- 14 May 2020
- Published by Wiley in Journal of Environmental and Public Health
- Vol. 2020, 1-15
Open AccessDetermination of Chromium in Natural Water by Adsorptive Stripping Voltammetry UsingIn SituBismuth Film Electrode
Development of adsorptive stripping voltammetry (AdSV) combined within situprepared bismuth film electrode (in situBiFE) on glassy carbon disk surface using diethylenetriamine pentaacetic acid (DTPA) as a complexing agent andas a catalyst to determine the trace amount of chromium (VI) is demonstrated. According to this method, in the preconcentration step atEdep = −800 mV, the bismuth film is coated on the surface of glassy carbon electrodes simultaneously with the adsorption of complexes Cr(III)-DTPA. In addition to the influencing factors, the stripping voltammetry performance factors such as deposition potential, deposition time, equilibration time, cleaning potential, cleaning time, and technical parameters of differential pulse and square wave voltammetries have been investigated, and the influence of Cr(III), Co(II), Ni(II), Ca(II), Fe(III),, Cl−, and Triton X has also been investigated. This method gained good repeatability with RSD <4% (n = 9) for the differential pulse adsorptive stripping voltammetry (DP-AdSV) and RSD < 3% (n = 7) for the square wave adsorptive stripping voltammetry (SqW-AdSV), and low limit of detection: LOD = 12.10−9 M ≈ 0.6 ppb (at a deposition potential (Edep) of −800 mV and the deposition time (tdep) of 50 s) and LOD = 2.10−9 M ≈ 0.1 ppb (atEdep = −800 mV andtdep = 160 s) for the DP-AdSV and SqW-AdSV, respectively. This method has been successfully applied to analyze chromium in natural water.