Shiyi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiyi Zhao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Alipujiang Jierula
College of Civil Engineering and Architecture, Xinjiang University, Urumqi 830046, China
3 shared publications - Xiaolong Li
College of Civil Engineering and Architecture, Xinjiang University, Urumqi 830017, China
2 shared publications - Bin Yang
College of Civil Engineering and Architecture, Xinjiang University, Urumqi 830017, China
1 shared publication - Haodong Li
College of Civil Engineering and Architecture, Xinjiang University, Urumqi 830046, China
1 shared publication - Hushitaer Niyazi
College of Civil Engineering and Architecture, Xinjiang University, Urumqi 830017, China
1 shared publication - Jin Wu
School of Civil Engineering and Architecture, Xinjiang University, Urumqi 830047, China
1 shared publication
Latest Publications
- Open Access
Experimental Study on Mechanical Properties of Silica Fume Foam Concrete After Exposure to High Temperatures
To investigate how the content of silica fume (SF) influences the performance of foam concrete (FC) after high-temperature exposure and the underlying mechanisms, this study prepared standard FC cube specimens with SF contents of 0%, 0.15%, 0.2%, 0.25%, and 0.3%. The working properties of the material at room temperature were systematically tested, and the mass loss, residual compressive strength, failure mode, microstructure and acoustic emission (AE) data at different temperatures (100 °C, 200 °C, 300 °C and 400 °C) were analyzed. The test results indicate that increasing the SF content reduces the fluidity of the fresh paste yet significantly enhances the compressive strength and lowers the water absorption of FC at room temperature. After high-temperature exposure, the effect of SF exhibits a dual character: at 200 °C and below, SF effectively mitigates the performance degradation of FC. However, when the temperature reaches 300–400 °C, specimens with an excessively high SF content (e.g., 0.3%) experience rapidly built-up internal steam pressure that cannot escape in time, which triggers the formation and propagation of a microcrack network and leads to a sharp drop in strength. Based on AE detection and scanning electron microscopy (SEM) image analysis, the failure process of silica fume foam concrete (SFFC) proceeds through three stages: free water evaporation at low temperatures, dehydration shrinkage of the C-S-H gel at medium temperatures, and finally, structural failure marked by the collapse of the C-S-H gel network at high temperatures. This study indicates that an SF content of 0.25% allows FC to achieve an optimal balance between mechanical properties and high-temperature stability. The findings provide a theoretical basis for optimizing FC mix proportions and enhancing fire prevention design.
Open AccessExperimental Study on Mechanical Properties of Silica Fume Foam Concrete After Exposure to High Temperatures
To investigate how the content of silica fume (SF) influences the performance of foam concrete (FC) after high-temperature exposure and the underlying mechanisms, this study prepared standard FC cube specimens with SF contents of 0%, 0.15%, 0.2%, 0.25%, and 0.3%. The working properties of the material at room temperature were systematically tested, and the mass loss, residual compressive strength, failure mode, microstructure and acoustic emission (AE) data at different temperatures (100 °C, 200 °C, 300 °C and 400 °C) were analyzed. The test results indicate that increasing the SF content reduces the fluidity of the fresh paste yet significantly enhances the compressive strength and lowers the water absorption of FC at room temperature. After high-temperature exposure, the effect of SF exhibits a dual character: at 200 °C and below, SF effectively mitigates the performance degradation of FC. However, when the temperature reaches 300–400 °C, specimens with an excessively high SF content (e.g., 0.3%) experience rapidly built-up internal steam pressure that cannot escape in time, which triggers the formation and propagation of a microcrack network and leads to a sharp drop in strength. Based on AE detection and scanning electron microscopy (SEM) image analysis, the failure process of silica fume foam concrete (SFFC) proceeds through three stages: free water evaporation at low temperatures, dehydration shrinkage of the C-S-H gel at medium temperatures, and finally, structural failure marked by the collapse of the C-S-H gel network at high temperatures. This study indicates that an SF content of 0.25% allows FC to achieve an optimal balance between mechanical properties and high-temperature stability. The findings provide a theoretical basis for optimizing FC mix proportions and enhancing fire prevention design.
- Open Access
- 2 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8591
Multi-Objective Optimization of Steel Slag–Ceramsite Foam Concrete via Integrated Orthogonal Experimentation and Multivariate Analytics: A Synergistic Approach Combining Range–Variance Analyses with Partial Least Squares Regression
This study aims to enhance the performance of an innovative steel slag–ceramsite foam concrete (SSCFC) to advance sustainable green building materials. An eco-friendly composite construction material was developed by integrating industrial by-product steel slag (SS) with lightweight ceramsite. Employing a three-factor, three-level orthogonal experimental design at a fixed density of 800 kg/m3, 12 mix proportions (including a control group) were investigated with the variables of water-to-cement (W/C) ratio, steel slag replacement ratio, and ceramsite replacement ratio. The governing mechanisms of the W/C ratio, steel slag replacement level, and ceramsite replacement proportion on the SSCFC’s fluidity and compressive strength (CS) were elucidated. The synergistic application of range analysis and analysis of variance (ANOVA) quantified the significance of factors on target properties, and partial least squares regression (PLSR)-based prediction models were established. The test results indicated the following significance hierarchy: steel slag replacement > W/C ratio > ceramsite replacement for fluidity. In contrast, W/C ratio > ceramsite replacement > steel slag replacement governed the compressive strength. Verification showed R2 values exceeding 65% for both fluidity and CS predictions versus experimental data, confirming model reliability. Multi-criteria optimization yielded optimal compressive performance and suitable fluidity at a W/C ratio of 0.4, 10% steel slag replacement, and 25% ceramsite replacement.
- 2 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8591
Open AccessMulti-Objective Optimization of Steel Slag–Ceramsite Foam Concrete via Integrated Orthogonal Experimentation and Multivariate Analytics: A Synergistic Approach Combining Range–Variance Analyses with Partial Least Squares Regression
This study aims to enhance the performance of an innovative steel slag–ceramsite foam concrete (SSCFC) to advance sustainable green building materials. An eco-friendly composite construction material was developed by integrating industrial by-product steel slag (SS) with lightweight ceramsite. Employing a three-factor, three-level orthogonal experimental design at a fixed density of 800 kg/m3, 12 mix proportions (including a control group) were investigated with the variables of water-to-cement (W/C) ratio, steel slag replacement ratio, and ceramsite replacement ratio. The governing mechanisms of the W/C ratio, steel slag replacement level, and ceramsite replacement proportion on the SSCFC’s fluidity and compressive strength (CS) were elucidated. The synergistic application of range analysis and analysis of variance (ANOVA) quantified the significance of factors on target properties, and partial least squares regression (PLSR)-based prediction models were established. The test results indicated the following significance hierarchy: steel slag replacement > W/C ratio > ceramsite replacement for fluidity. In contrast, W/C ratio > ceramsite replacement > steel slag replacement governed the compressive strength. Verification showed R2 values exceeding 65% for both fluidity and CS predictions versus experimental data, confirming model reliability. Multi-criteria optimization yielded optimal compressive performance and suitable fluidity at a W/C ratio of 0.4, 10% steel slag replacement, and 25% ceramsite replacement.
- Open Access
Numerical Simulation-Based Study on Influence of Different Connection Configurations of Viscous Dampers on Seismic Performance
To investigate the influence of different connection configurations of viscous dampers on seismic mitigation performance, this study conducts a numerical simulation analysis of a 10-story inpatient building in Bazhou People’s Hospital, comparing the energy dissipation efficacy of viscous dampers under three connection types: diagonal bracing, chevron bracing, and wall-mounted connections. The results demonstrate that both chevron and wall-mounted configurations exhibit superior seismic mitigation performance compared to diagonal bracing. Specifically, chevron bracing is more suitable for mid- to high-rise structures, while wall-mounted connections achieve marginally better performance in low-rise buildings. However, the latter’s efficacy diminishes in mid- to high-rise structures due to the influence of wall self-weight. This study provides practical insights for optimizing the arrangement and application of viscous dampers in engineering projects.
Open AccessNumerical Simulation-Based Study on Influence of Different Connection Configurations of Viscous Dampers on Seismic Performance
To investigate the influence of different connection configurations of viscous dampers on seismic mitigation performance, this study conducts a numerical simulation analysis of a 10-story inpatient building in Bazhou People’s Hospital, comparing the energy dissipation efficacy of viscous dampers under three connection types: diagonal bracing, chevron bracing, and wall-mounted connections. The results demonstrate that both chevron and wall-mounted configurations exhibit superior seismic mitigation performance compared to diagonal bracing. Specifically, chevron bracing is more suitable for mid- to high-rise structures, while wall-mounted connections achieve marginally better performance in low-rise buildings. However, the latter’s efficacy diminishes in mid- to high-rise structures due to the influence of wall self-weight. This study provides practical insights for optimizing the arrangement and application of viscous dampers in engineering projects.