Shefra Shah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shefra Shah has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dumitru Mazilu
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Eric E. Bennett
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Farah Hussaini
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Han Wen
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications
Latest Publications
- Open Access
- 13 June 2025
- Published by MDPI AG in Methods and Protocols
- Vol. 8 (3)
Cystic Lung Phantom to Validate Clinical CT Protocols
In computed tomography (CT)-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. We describe an easy-to-replicate cystic lung phantom consisting of basic lung structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner, various structures in the lung phantom were correctly recognized by two types of lung analysis software. The resulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. The significant finding was that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and deserves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
- 13 June 2025
- Published by MDPI AG in Methods and Protocols
- Vol. 8 (3)
Open AccessCystic Lung Phantom to Validate Clinical CT Protocols
In computed tomography (CT)-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. We describe an easy-to-replicate cystic lung phantom consisting of basic lung structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner, various structures in the lung phantom were correctly recognized by two types of lung analysis software. The resulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. The significant finding was that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and deserves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
- Open Access
Cystic Lung Phantom to Validate Clinical CT Protocols
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
Open AccessCystic Lung Phantom to Validate Clinical CT Protocols
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.