Lena Kreie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lena Kreie has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Hassel
Leibniz Universität Hannover
3 shared publications - Hans Jürgen Maier
Leibniz Universität Hannover
2 shared publications - Christian Mills
Institut für Werkstoffkunde (Materials Science) , Leibniz Universität Hannover , 30823 Garbsen , Germany
1 shared publication - David Kramer
Institut für Werkstoffkunde (Materials Science) Leibniz Universität Hannover Garbsen Germany
1 shared publication - Finn‐Lennard Janthur
Institute for Transport and Automation Technology Leibniz University Hannover Hannover Lower Saxony Germany
1 shared publication - Johannes May
Laser Zentrum Hannover e.V. Hannover Germany
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (12)
Surface Tension Measurement of Ti‐6Al‐4V by Falling Droplet Method in Oxygen‐Free Atmosphere
Surface tension plays a key role in determining melt behavior, wetting, and defect formation in high‐temperature processes such as laser powder bed fusion and wire‐based deposition welding. Accurate surface tension data are therefore essential for optimizing process quality, especially for titanium alloys, like Ti‐6Al‐4V, which are widely used in aerospace and biomedical applications due to their high specific strength and biocompatibility. In this article, the surface tension of Ti‐6Al‐4V is derived from the oscillation of falling droplets using Rayleigh's formula. Conventional levitating droplet techniques for reactive materials require complex evaluation algorithms and specialized hardware to maintain microgravity conditions. In contrast, the presented approach employs only a single high‐speed camera for simultaneous temperature and droplet oscillation measurements, enabling flexible and cost‐effective integration into various technical systems. The method is applied to investigate the influence of residual oxygen on the surface tension by performing experiments in argon and in a monosilane‐doped oxygen‐free atmosphere (−15 ppm O 2 ). The surface tension follows the linear relation γ ( T ) = 1.512 N m −1 − 1.468 × 10 −4 N m −1 K −1 × ( T − 1933 K). No measurable influence of residual oxygen was observed, as the droplet lifetime was four orders of magnitude shorter than the time required for substantial oxygen diffusion.
- 1 March 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (12)
Open AccessSurface Tension Measurement of Ti‐6Al‐4V by Falling Droplet Method in Oxygen‐Free Atmosphere
Surface tension plays a key role in determining melt behavior, wetting, and defect formation in high‐temperature processes such as laser powder bed fusion and wire‐based deposition welding. Accurate surface tension data are therefore essential for optimizing process quality, especially for titanium alloys, like Ti‐6Al‐4V, which are widely used in aerospace and biomedical applications due to their high specific strength and biocompatibility. In this article, the surface tension of Ti‐6Al‐4V is derived from the oscillation of falling droplets using Rayleigh's formula. Conventional levitating droplet techniques for reactive materials require complex evaluation algorithms and specialized hardware to maintain microgravity conditions. In contrast, the presented approach employs only a single high‐speed camera for simultaneous temperature and droplet oscillation measurements, enabling flexible and cost‐effective integration into various technical systems. The method is applied to investigate the influence of residual oxygen on the surface tension by performing experiments in argon and in a monosilane‐doped oxygen‐free atmosphere (−15 ppm O 2 ). The surface tension follows the linear relation γ ( T ) = 1.512 N m −1 − 1.468 × 10 −4 N m −1 K −1 × ( T − 1933 K). No measurable influence of residual oxygen was observed, as the droplet lifetime was four orders of magnitude shorter than the time required for substantial oxygen diffusion.
- Open Access
- 8 February 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (12) , e202502558
Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma
One promising approach to keep the residual oxygen level in welding at extremely low levels is to add monosilane to the argon shielding gas. However, its effect on the plasma itself is not clear, and thus this study examines the influence of a silane‐doped argon atmosphere on the chemical components and temperature within a nontransferring, thermal argon plasma in comparison to an atmosphere of pure argon and air. For this purpose, the emitted radiation of the plasma was analyzed using optical emission spectroscopy. The spectra show that the Ar I lines are most prominent in all atmospheres. Compared to the air atmosphere, the plasma in the argon atmosphere exhibits a stronger H I line and an OH emission band. A slight doping of the argon atmosphere with silane (0.01 vol.%) leads to strongly pronounced Si I and H I lines and a clearly recognizable H 2 emission band. The high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule leads to an increase in plasma temperature from about 7,600 to 9,000 K.
- 8 February 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (12) , e202502558
Open AccessInfluence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma
One promising approach to keep the residual oxygen level in welding at extremely low levels is to add monosilane to the argon shielding gas. However, its effect on the plasma itself is not clear, and thus this study examines the influence of a silane‐doped argon atmosphere on the chemical components and temperature within a nontransferring, thermal argon plasma in comparison to an atmosphere of pure argon and air. For this purpose, the emitted radiation of the plasma was analyzed using optical emission spectroscopy. The spectra show that the Ar I lines are most prominent in all atmospheres. Compared to the air atmosphere, the plasma in the argon atmosphere exhibits a stronger H I line and an OH emission band. A slight doping of the argon atmosphere with silane (0.01 vol.%) leads to strongly pronounced Si I and H I lines and a clearly recognizable H 2 emission band. The high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule leads to an increase in plasma temperature from about 7,600 to 9,000 K.