Tao Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Han has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jiangbiao He
Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN, USA
1 shared publication Liang Zhang
1 shared publication- Luocheng Wang
Electrical and Computer Engineering Department, University of North Carolina at Charlotte, NC, USA
1 shared publication - Nirwan Ansari
New Jersey Institute of Technology, Newark, New Jersey, USA
1 shared publication - Tiefu Zhao
Department of Electrical and Computer Engineering, University of North Carolina at Charlotte, Charlotte, NC 28223, USA
1 shared publication
Latest Publications
- 30 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Finite Control Set Model Predictive Control with Secondary Problem Formulation for Power Loss and Thermal Stress Reductions
Thermal stress has been identified as one of the major failure causes in power modules. Generated from the power loss, thermal stress accelerates the degradation of semiconductor devices and downgrades the system reliability. This paper presents a finite control set model predictive control (FCS-MPC) oriented to reduce the power loss over the mission profile and relieve the thermal stress in power modules. Conventional control approaches including the switching frequency regulation, the reactive power injection and the DC bus voltage adaption show an effective progress. However, the increased control loops and complicated modulation schemes limit the system performance and practical implementation. In the proposed FCS-MPC, a secondary problem formulation is defined to reduce the power loss for the thermal stress reduction in power modules. It is simply integrated with the primary problem formulation in order to achieve the power flow control and power loss reduction simultaneously. An energy-based loss model is proposed for the loss prediction. The impact of the weightings between primary and secondary problem formulations is investigated and a most efficient weighting curve with a weighting-zones strategy is presented to design the proposed FCS-MPC. The proposed FCS-MPC is validated in the simulation studies and experiments. A 2.5-kW grid-tied inverter prototype is developed for the hardware testing and validation.
- 30 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Finite Control Set Model Predictive Control with Secondary Problem Formulation for Power Loss and Thermal Stress Reductions
Thermal stress has been identified as one of the major failure causes in power modules. Generated from the power loss, thermal stress accelerates the degradation of semiconductor devices and downgrades the system reliability. This paper presents a finite control set model predictive control (FCS-MPC) oriented to reduce the power loss over the mission profile and relieve the thermal stress in power modules. Conventional control approaches including the switching frequency regulation, the reactive power injection and the DC bus voltage adaption show an effective progress. However, the increased control loops and complicated modulation schemes limit the system performance and practical implementation. In the proposed FCS-MPC, a secondary problem formulation is defined to reduce the power loss for the thermal stress reduction in power modules. It is simply integrated with the primary problem formulation in order to achieve the power flow control and power loss reduction simultaneously. An energy-based loss model is proposed for the loss prediction. The impact of the weightings between primary and secondary problem formulations is investigated and a most efficient weighting curve with a weighting-zones strategy is presented to design the proposed FCS-MPC. The proposed FCS-MPC is validated in the simulation studies and experiments. A 2.5-kW grid-tied inverter prototype is developed for the hardware testing and validation.
- Open Access
Renewable Energy-Aware Inter-datacenter Virtual Machine Migration over Elastic Optical Networks
Datacenters (DCs) are deployed in a large scale to support the ever increasing demand for data processing to support various applications. The energy consumption of DCs becomes a critical issue. Powering DCs with renewable energy can effectively reduce the brown energy consumption and thus alleviates the energy consumption problem. Owing to geographical deployments of DCs, the renewable energy generation and the data processing demands usually vary in different DCs. Migrating virtual machines (VMs) among DCs according to the availability of renewable energy helps match the energy demands and the renewable energy generation in DCs, and thus maximizes the utilization of renewable energy. Since migrating VMs incurs additional traffic in the network, the VM migration is constrained by the network capacity. The inter-datacenter (inter-DC) VM migration with network capacity constraints is an NP-hard problem. In this paper, we propose two heuristic algorithms that approximate the optimal VM migration solution. Through extensive simulations, we show that the proposed algorithms, by migrating VM among DCs, can reduce up to 31% of brown energy consumption.
Open AccessRenewable Energy-Aware Inter-datacenter Virtual Machine Migration over Elastic Optical Networks
Datacenters (DCs) are deployed in a large scale to support the ever increasing demand for data processing to support various applications. The energy consumption of DCs becomes a critical issue. Powering DCs with renewable energy can effectively reduce the brown energy consumption and thus alleviates the energy consumption problem. Owing to geographical deployments of DCs, the renewable energy generation and the data processing demands usually vary in different DCs. Migrating virtual machines (VMs) among DCs according to the availability of renewable energy helps match the energy demands and the renewable energy generation in DCs, and thus maximizes the utilization of renewable energy. Since migrating VMs incurs additional traffic in the network, the VM migration is constrained by the network capacity. The inter-datacenter (inter-DC) VM migration with network capacity constraints is an NP-hard problem. In this paper, we propose two heuristic algorithms that approximate the optimal VM migration solution. Through extensive simulations, we show that the proposed algorithms, by migrating VM among DCs, can reduce up to 31% of brown energy consumption.