JGJin-Hong Gerds-Li

Jin-Hong Gerds-Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jin-Hong Gerds-Li has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sex-associated differences in lesion delivery and atrial fibrillation recurrence after cryoballoon ablation

    by Emanuel Heil, Matthias Bock, Julia Knocks, Jan Paul Rudolph, Jin-Hong Gerds-Li, Frank Heinzel, Philipp Attanasio, Abdul Shokor Parwani, Hendrik Boldt, Florian Blaschke, et al.

  • Open Access

    Predictors of iatrogenic atrial septal defects: analysis of fibrotic atrial cardiomyopathy, valvular disease, and transseptal sheath size

    by Emanuel Heil, Jin-Hong Gerds-Li, Matthias Bock, Frank Heinzel, Gerhard Hindricks, Felix Hohendanner

    Background: Transseptal puncture (TSP) for left atrial access is routinely used during various cardiac interventions, including ablation for atrial tachyarrhythmia. However, in selected patients, subsequent iatrogenic atrial septal defects (iASD) persist. This study determines whether fibrotic atrial cardiomyopathy (FACM) or mitral valve regurgitation (MR) are predictors of persistent iASD development post-TSP. Methods: We analyzed data from patients undergoing radiofrequency ablation with high-density electroanatomical mapping for recurrent atrial tachyarrhythmias after a primary pulmonary vein isolation using either cryo or RF technologies. Patients were categorized based on transesophageal echocardiography findings: (1) competent atrial septum (cAS) (2), iASD, or (3) a patent foramen ovale (PFO). Differences in FACM and MR were assessed across these groups. Results: Of 149 patients (age 67.7 ± 9.7 years), 125 (83.9%) had cAS, 8 (5.4%) iASD, and 16 (10.7%) PFO. No significant differences were observed in age (p = 0.932), BMI (p = 0.612), or LVEF (p = 0.581). The TSP sheath size was not associated with iASD occurrence (p = 0.857). Common surrogates of FACM, i.e., LAVI (p = 0.114), LA area (p = 0.156), mean left atrial pressure (LAP; p = 0.459), or total low-voltage area burden (p = 0.058) did not differ significantly among groups. MR was not linked to increased LAP (at first (p = 0.290) and second procedure (p = 0.212)) or a higher incidence of iASD (at first (p = 0.155) and second procedure (p = 0.917)). Mean LAP did not correlate with LA size (p = 0.471) or low-voltage extent (p = 0.084). Conclusion: Our findings underscore that iASDs post-TSP for left atrial ablation are uncommon and unrelated to TSP sheath size, FACM, or MR, further minimizing concerns for routine interventions in patients with more advanced arrhythmia substrate or valvular disease. Graphical

  • Precordial electrode placement for optimal ECG monitoring: Implications for ambulatory monitor devices and event recorders

    by Sotirios Nedios, Iñaki Romero, Jin-Hong Gerds-Li, Eckard Fleck, Charalampos Kriatselis


  • Open Access

    Cardiovascular magnetic resonance imaging for accurate sizing of the left atrium: Predictability of pulmonary vein isolation success in patients with atrial fibrillation

    by Cosima Jahnke, Julia Fischer, Jesus Gonzalez Mirelis, Charalampos Kriatselis, Jin‐Hong Gerds‐Li, Rolf Gebker, Robert Manka, Bernhard Schnackenburg, Eckart Fleck, Ingo Paetsch

    Purpose To prospectively determine the most reproducible approach for left‐atrial size assessment using cardiovascular magnetic resonance (CMR) imaging in patients with atrial fibrillation and its value for prediction of pulmonary vein isolation (PVI) treatment success. Materials and Methods Eighty patients underwent CMR imaging prior to PVI; the CMR examination included standard cine sequences, a multislice cine sequence in 4‐chamber orientation with full left‐atrial coverage, and a contrast‐enhanced MR angiography of the left atrium. Left‐atrial size was determined as: diameter, area, volume segmented from angiography, and diastolic/systolic volumes from cine imaging (Simpson's rule). All measurements were carried out by two independent observers and repeated by one observer to assess inter‐ and intrareader variability. Treatment success was defined as persisting sinus rhythm after PVI (follow‐up period 12.6 ± 6.6 months). Results All left‐atrial measurements showed substantial intrareader agreement. Interreader agreement was substantial for diastolic/systolic left‐atrial volumes only. Calculated bias was found to be minimal (0.1%–4.9%). Predictability of PVI treatment success was best using cine volumetric measurements (cutoff value for diastolic volume, 112 mL) yielding a sensitivity and specificity of 80% and 70%, respectively. Conclusion Left‐atrial volumetry based on cine imaging represented the most reproducible approach to determine left‐atrial size. PVI success was predicted best using cine volumetry. J. Magn. Reson. Imaging 2011;33:455–463.


  • Open Access

    Radiofrequency ablation in children and adolescents: results in 154 consecutive patients

    by Jens Cosedis Nielsen, Hans Kottkamp, Christopher Piorkowski, Jin-Hong Gerds-Li, Hildegard Tanner, Gerhard Hindricks

    Aims The experience of using radiofrequency ablation (RFA) for the treatment of arrhythmias in children and adolescents is still limited. This study aimed to review the most recent results of RF ablation in children and adolescents in a highly experienced centre with access to both conventional techniques and non-fluoroscopic electroanatomic mapping (CARTO). Methods and results A total of 154 consecutive patients younger than 19 years treated with RFA during the period 2000–04 were included. Numbers (%) or median (quartiles) are reported. Age was 15 (12–17) years, 70 (45%) were males. Five patients (3%) had congenital heart disease. RFA was successful in 147/154 patients (95%). Arrhythmia recurrence occurred in 11 patients (7%). Procedure time was 55 (35–90) min and fluoroscopy time was 8.8 (4–19) min. Number of RF applications was 4 (2–10) and number of RF applications >20 s was 2 (1–7). One patient (0.7%) had complicating high-grade atrioventricular block. CARTO was used in 18 RF ablation procedures (11%) performed in 15 patients. Conclusion RF ablation can be undertaken in children and adolescents with a high success rate, few recurrences and complications, very short procedure times, and acceptable fluoroscopy times. Non-fluoroscopic electroanatomic mapping is helpful in selected patients.


  • Trigger Activity More Than Three Years After Left Atrial Linear Ablation Without Pulmonary Vein Isolation in Patients With Atrial Fibrillation

    by Hildegard Tanner, Gerhard Hindricks, Richard Kobza, Anja Dorszewski, Petra Schirdewahn, Christopher Piorkowski, Jin-Hong Gerds-Li, Hans Kottkamp


  • Radiofrequency ablation of accessory pathways

    by R. Kobza, H. Kottkamp, C. Piorkowski, H. Tanner, P. Schirdewahn, A. Dorszewski, U. Wetzel, J.-H. Gerds-Li, A. Arya, G. Hindricks

    Zusammenfassung Einleitung Das Ziel dieser Studie war es, 17 Jahre nach der ersten Hochfrequenzstrom (HF)-Katheterablation einer akzessorischen Bahn, die gegenwärtig erreichten Erfolgsraten der HF-Ablation akzessorischer Leitungsbahnen zusammen mit den Prozedurdaten und Komplikationsraten zu analysieren. Da bisherige Untersuchungen über die Lokalisation akzessorischer Leitungsbahnen noch auf der alten Nomenklatur basieren, war es ein weiteres Ziel, die Verteilung akzessorischer atrioventrikulärer Leitungsbahnen unter Gebrauch der 1999 von ESC und NASPE eingeführten neuen Nomenklatur zu analysieren. Methoden Es wurden die Daten aller Patienten, bei denen zwischen dem 1. 1. 2000 und dem 31. 12. 2003 am Herzzentrum Leipzig eine akzessorische Bahn abladiert wurde, retrospektiv analysiert. Resultate Über einen Zeitraum von 4 Jahren wurden an unserem Zentrum insgesamt 336 akzessorische Bahnen bei 323 Patienten abladiert. Gemäß der neuen Nomenklatur wurden die Bahnen eingeteilt in links gelegene, rechts gelegene, septale und paraseptale akzessorische Bahnen. 188 der Bahnen (56%) lagen links, 41 (12%) rechts, 64 (19%) (infero-)paraseptal und 31 (9%) septal oder parahissär. 12 Bahnen (4%) zeigten atypische Verläufe und/oder Eigenschaften und konnten somit nicht klar zugeordnet werden. Die mittlere Prozedurdauer betrug 68±37 Minuten. Die Erfolgsrate betrug insgesamt 98%. Bei 289 der Patienten (89%) konnte die akzessorische Bahn in einer einzigen Untersuchung erfolgreich abladiert werden. Komplikationen traten bei weniger als 2% der behandelten Patienten auf. Konklusion 17 Jahre nach Durchführung der ersten HF-Katheterablation einer akzessorischen Leitungsbahn hat sich diese als hocheffektive und komplikationsarme kurative Behandlungsmethode etabliert. Die Erfolgsraten sind in den letzten 10 Jahren weiter gestiegen und die Komplikationsraten konnten weiter gesenkt werden. Mit der Einführung der neuen Nomenklatur ist es für den interventionellen Elektrophysiologen leichter geworden, die Lokalisation einer akzessorischen Bahn gemäß der realen anatomischen Lage im Körper festzulegen.