Yuying Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yuying Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Li Chang
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
2 shared publications - Meiyuan Yang
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
2 shared publications - Zhengdao Zhou
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
2 shared publications - Zhenying Zhang
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
2 shared publications - Yang Li
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
1 shared publication - Zheng Guan
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
1 shared publication
Latest Publications
- Open Access
- 8 September 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (9) , 505
Assessment of Ejector-Expansion Heat Pump Systems with Low GWP Refrigerants for Electric Vehicles
This study addresses the critical challenge of developing efficient thermal management systems for electric vehicles by proposing and evaluating two novel ejector-expansion heat pump configurations: single-evaporator (SEEHP) and dual-evaporator (DEEHP) systems. Through comprehensive thermodynamic analysis across six representative Chinese cities using four refrigerants (R134a, R32, R152a, R290), system performance via coefficient of performance (COP) and lifecycle CO2 emissions were assessed. The results demonstrate significant advantages over conventional (CBHP) and vapor injection (VIHP) systems, particularly in extreme cold conditions. The SEEHP configuration achieves 10–30% COP improvements versus CBHP, while DEEHP shows 7–15% enhancement. The corresponding lifecycle emission reductions reach 9–14% for SEEHP and 2–11% for DEEHP relative to conventional systems. Among the refrigerants, R290 systems achieve the lowest equivalent CO2 emissions due to superior COP in Beijing, Shanghai, Chongqing, Kunming and Guangzhou, whereas R32 systems yield minimal emissions owing to its exceptional heating capacity in Harbin. These findings highlight ejector technology’s potential for substantially improving electric vehicle energy efficiency while reducing environmental impact.
- 8 September 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (9) , 505
Open AccessAssessment of Ejector-Expansion Heat Pump Systems with Low GWP Refrigerants for Electric Vehicles
This study addresses the critical challenge of developing efficient thermal management systems for electric vehicles by proposing and evaluating two novel ejector-expansion heat pump configurations: single-evaporator (SEEHP) and dual-evaporator (DEEHP) systems. Through comprehensive thermodynamic analysis across six representative Chinese cities using four refrigerants (R134a, R32, R152a, R290), system performance via coefficient of performance (COP) and lifecycle CO2 emissions were assessed. The results demonstrate significant advantages over conventional (CBHP) and vapor injection (VIHP) systems, particularly in extreme cold conditions. The SEEHP configuration achieves 10–30% COP improvements versus CBHP, while DEEHP shows 7–15% enhancement. The corresponding lifecycle emission reductions reach 9–14% for SEEHP and 2–11% for DEEHP relative to conventional systems. Among the refrigerants, R290 systems achieve the lowest equivalent CO2 emissions due to superior COP in Beijing, Shanghai, Chongqing, Kunming and Guangzhou, whereas R32 systems yield minimal emissions owing to its exceptional heating capacity in Harbin. These findings highlight ejector technology’s potential for substantially improving electric vehicle energy efficiency while reducing environmental impact.
- Open Access
Parametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems
The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.
Open AccessParametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems
The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.