SSSupratim Saha

Supratim Saha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Supratim Saha has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Beyond Shear Magnitude: Temporal Regulation of Mechanotransduction in Renal Epithelial Cells

    by Supratim Saha, Silpa Arkat, Nithya Murugesan, Sarit K. Das

    Renal epithelial mechanotransduction is essential for maintaining tubular physiology by enabling epithelial cells to sense and adapt to their local mechanical environment, while disruption of these mechanosensitive processes may contribute to altered epithelial function during chronic kidney disease (CKD). Fluid shear stress (FSS) is a major regulator of renal epithelial mechanotransduction. However, most studies have focused on moderate-tohigh shear regimes (≈0.2-2 dyn/cm²), while the ultra-low shear conditions relevant to compromised renal function remain poorly understood. CKD is associated with reduced tubular flow, exposing epithelial cells to near-threshold shear stresses (~10⁻²-10⁻¹ dyn/cm²), where the mechanisms governing cellular adaptation remain largely unknown. In this study, we systematically investigated the combined influence of shear magnitude, exposure duration, and temporal continuity on renal epithelial mechanotransduction using a microfluidic platform. MDCK cells were exposed to static, intermittent, and continuous ultra-low shear conditions, and their responses were evaluated through intracellular calcium signaling, cytoskeletal organization (F-actin), nuclear response (DAPI), and quantitative morphological analysis over 0-12 h. Continuous flow consistently produced the strongest mechanobiological response, followed by intermittent flow and static culture, demonstrating that epithelial adaptation depends not only on shear magnitude but also on the duration and continuity of mechanical stimulation. A coordinated temporal progression was observed, beginning with calcium signaling, followed by cytoskeletal remodeling, nuclear response, and ultimately the development of a flow-adapted morphological phenotype. To quantitatively describe this behavior, a first-order mechanoadaptation model was developed to capture the temporal evolution of epithelial morphology and identify a characteristic adaptation timescale. Collectively, these findings demonstrate that sustained ultra-low shear stress is sufficient to induce significant renal epithelial adaptation and highlight the importance of shear magnitude, exposure duration, and flow continuity in regulating mechanotransduction under physiologically relevant low-flow conditions. The proposed experimental and quantitative framework provides new insight into epithelial adaptation in CKD and establishes a physiologically relevant foundation for kidney-on-chip platforms, disease modeling, and therapeutic screening.

  • Open Access

    Pulsatile Flow Reorganization in Patient-derived Eccentric Coronary Stenoses: Coupled Effects of Lesion Asymmetry and Heart-Rate-dependent Inertia

    by Sayan Karmakar, Kashvi Aggarwal, Supratim Saha

    Eccentric coronary stenoses generate asymmetric jets and complex secondary motion, yet their interaction with heart-rate-induced pulsatility remains incompletely resolved. Pulsatile non-Newtonian blood flow is simulated in a patient-derived left coronary artery containing concentric and two controlled eccentric stenoses with 70% luminal narrowing while preserving the parent anatomy and lesion severity. The incompressible Navier-Stokes equations are solved using a finite-element formulation with Carreau rheology at heart rates of 67, 100, and 140 BPM. Phase-resolved axial and secondary velocities, vorticity, helicity, time-averaged wall shear stress, oscillatory shear index, relative residence time, pressure drop, and hydraulic resistance are quantified. Increasing eccentricity progressively deflects the stenotic jet and strengthens secondary and helical motion, with the Type II lesion producing the most persistent post-stenotic rotational structures and the largest pressure penalty. Increasing heart rate amplifies peak jet velocity, vorticity, helicity, and wall shear stress, but shortens the time available for vortex development, thereby confining flow reversal and reducing the spatial extent of elevated oscillatory shear and residence time. In the Type II lesion, the secondary-to-axial velocity ratio increases by more than fivefold between 67 and 140 BPM, while hydraulic resistance nearly triples. A regime-based interpretation using Reynolds number, Womersley number, and a curvature-based eccentricity parameter explains the coexistence of stronger instantaneous rotation with weaker cycle-integrated recirculation at elevated heart rate. The results identify lesion asymmetry and pulsatile inertia as coupled controls of flow organization, wall-shear heterogeneity, and irreversible pressure loss.

  • Deformation-driven hemodynamics in a compliant coronary artery with serial stenosis: A layer-resolved fluid–structure interaction study

    by Sayan Karmakar, Nandish Pai, Arnab Chakraborty, Supratim Saha

    Coronary artery disease manifests as serial stenosis in compliant vessels, where pulsatile flow, wall deformation, and plaque heterogeneity govern hemodynamic behavior. This study develops a two-way fluid–structure interaction framework to investigate blood flow through a compliant coronary artery with serial stenoses. The arterial wall uses a three-layer representation. The intima, media, adventitia, and fibrous cap are treated as hyperelastic solids, while the encapsulated lipid pool is modeled as a linear elastic inclusion. Blood is represented as a non-Newtonian Carreau fluid to capture shear-dependent rheology. By varying plaque stiffness and pulsatile inertia, quantified through the Womersley number (Wo), the analysis resolves lumen dynamics, pressure loss, vortex structure, and near-wall transport. Increasing plaque stiffness from 100 kPa to 10 MPa suppresses radial wall deformation by approximately 30%–50%, preserves a narrower lumen, and intensifies jet acceleration and adverse pressure gradients across interacting lesions. This increases cycle-averaged pressure drop and hemodynamic resistance by nearly two times. Elevated heart rate, with Wo increasing from 2.49 to 3.04, enhances unsteady inertial effects and raises peak pressure drop by approximately 40%–60%. These effects modify clinical indices, with peak time-averaged wall shear stress increasing by up to ∼50% and fractional flow reserve (FFR) decreasing from approximately 0.83 to 0.60 across the stiffness range. Finally, a force-based scaling analysis quantifies the roles of elastic resistance, pulsatile inertia, and viscous dissipation. The resulting linear collapse of normalized pressure loss provides mechanistic interpretation of trans-stenotic pressure deficits in compliant, serially stenosed coronary arteries.


  • Hemodynamic and hemorheological variations in coronary arteries: impact of stenosis geometry and disease-driven viscosity changes

    by Sayan Karmakar, Kashvi Aggarwal, Supratim Saha

    Purpose: The purpose of this study is to investigate the combined effects of stenosis geometry and hematocrit (Hct)-dependent blood rheology on coronary hemodynamics. While geometric asymmetry and viscosity variation individually influence flow behavior, their coupled impact remains insufficiently characterized. Clarifying this interaction is important for improving the relevance of patient-specific numerical hemodynamic analyses in clinical diagnostic contexts, where variations in vascular structure and Hct can significantly affect disease progression. Design/methodology/approach: A patient-specific left coronary artery with 70% luminal narrowing was reconstructed from computed tomography imaging and analyzed for concentric and eccentric (Type I and II) lesions. Pulsatile flow was simulated using a finite-element incompressible Navier–Stokes framework with a Carreau non-Newtonian viscosity model at Hct levels of 25%, 45% and 65%. The model was validated against established experimental and numerical simulation data, and key hemodynamic and energetic metrics were evaluated over the cardiac cycle. Findings: Eccentric Type II lesions produced the greatest flow disruption, characterized by strong post-stenotic separation, elevated oscillatory shear and increased pressure losses. Hct regulated flow stability, with reduced viscosity enhancing inertial effects and residence time and increased viscosity amplifying dissipative losses. Geometric asymmetry caused uneven momentum redistribution, generating skewed jets and persistent secondary vortices that promoted transitions from coherent pulsatile flow to vortex-dominated dynamics. Originality/value: This work presents a patient-specific computational framework that integrates lesion eccentricity with Hct-driven non-Newtonian blood behavior. By isolating the coupled effects of morphology and rheology, this study provides a physically grounded basis for interpreting coronary flow disturbances and supports improved non-invasive cardiovascular risk assessment.


  • Geometry-assisted segregation of multiple blood plasma analytes in paper-based microfluidic devices

    by Nithya Murugesan, Arnov Paul, Supratim Saha, Azharuddin Mohammed, E. Nivedita, Gowri Shanker, Sarit K. Das

  • Open Access

    Deformation Driven Hemodynamics in a Compliant Coronary Artery With Serial Stenosis: A Layer-Resolved Fluid-Structure Interaction Study

    by Sayan Karmakar, Nandish Pai, Arnab Chakraborty, Supratim Saha

    Coronary artery disease often manifests as serial stenosis in mechanically compliant vessels, where pulsatile flow, wall deformation, and plaque heterogeneity govern hemodynamic behavior. This study develops a two-way fluid-structure interaction (FSI) framework to investigate pulsatile blood flow through a compliant coronary artery with serial stenoses. The arterial wall is modeled using a realistic three-layer representation. The intima, media, adventitia, and fibrous cap are treated as hyperelastic solids, while the encapsulated lipid pool is modeled as a linear elastic inclusion. Blood is represented as a non-Newtonian Carreau fluid to capture shear-dependent rheology under physiological conditions. By systematically varying plaque stiffness and pulsatile inertia, quantified through the Womersley number (Wo), the analysis resolves modulation of lumen dynamics, pressure loss, vortex structure, and near-wall transport. Increasing plaque stiffness suppresses wall deformation, preserves a narrower effective lumen, and intensifies jet acceleration and adverse pressure gradients across interacting lesions. This leads to increased cycleaveraged pressure drop and hemodynamic resistance. Elevated heart rate enhances unsteady inertial effects, strengthens temporal pressure fluctuations, and prolongs post-stenotic vortex persistence, particularly in serial stenosis where upstream flow preconditioning alters downstream dynamics. These effects modify clinically relevant indices such as fractional flow reserve, time-averaged wall shear stress, and wall shear stress divergence, indicating deformation-dependent changes in near-wall convective transport. A forcebased scaling analysis quantifies the relative roles of elastic resistance, pulsatile inertia, and viscous dissipation. The resulting linear collapse of normalized pressure loss provides a mechanistic interpretation of trans-stenotic pressure deficits in compliant, serially stenosed arteries.


  • Open Access

    Deformation Driven Hemodynamics in a Compliant Coronary Artery With Serial Stenosis: A Layer-Resolved Fluid-Structure Interaction Study

    by Sayan Karmakar, Nandish Pai, Arnab Chakraborty, Supratim Saha

    Coronary artery disease often manifests as serial stenosis in mechanically compliant vessels, where pulsatile flow, wall deformation, and plaque heterogeneity govern hemodynamic behavior. This study develops a two-way fluid-structure interaction (FSI) framework to investigate pulsatile blood flow through a compliant coronary artery with serial stenoses. The arterial wall is modeled using a realistic three-layer representation. The intima, media, adventitia, and fibrous cap are treated as hyperelastic solids, while the encapsulated lipid pool is modeled as a linear elastic inclusion. Blood is represented as a non-Newtonian Carreau fluid to capture shear-dependent rheology under physiological conditions. By systematically varying plaque stiffness and pulsatile inertia, quantified through the Womersley number (Wo), the analysis resolves modulation of lumen dynamics, pressure loss, vortex structure, and near-wall transport. Increasing plaque stiffness suppresses wall deformation, preserves a narrower effective lumen, and intensifies jet acceleration and adverse pressure gradients across interacting lesions. This leads to increased cycleaveraged pressure drop and hemodynamic resistance. Elevated heart rate enhances unsteady inertial effects, strengthens temporal pressure fluctuations, and prolongs post-stenotic vortex persistence, particularly in serial stenosis where upstream flow preconditioning alters downstream dynamics. These effects modify clinically relevant indices such as fractional flow reserve, time-averaged wall shear stress, and wall shear stress divergence, indicating deformation-dependent changes in near-wall convective transport. A forcebased scaling analysis quantifies the relative roles of elastic resistance, pulsatile inertia, and viscous dissipation. The resulting linear collapse of normalized pressure loss provides a mechanistic interpretation of trans-stenotic pressure deficits in compliant, serially stenosed arteries.

  • Unraveling the dynamics of pulsatile flow under pathophysiological conditions in curved tubules of kidney

    by Supratim Saha, Nithya Murugesan, Sarit K. Das

    Chronic kidney disease (CKD) is a critical global health challenge that requires a deeper understanding of kidney physiology and pathology to develop effective therapeutic strategies. This necessitates a thorough exploration of fluid dynamic interactions within the elastic kidney tubules. This study introduces a biomechanical model to investigate the dynamics of fluid flow in elastic kidney tubules while incorporating their physiological curvature characteristics. We present a numerical model to analyze pulsatile flow dynamics in the kidney tubules, incorporating curvature and compliance variations. A finite-element framework is used to evaluate flow parameters across varying wall stiffnesses, with validation against data from the literature. Our findings highlight that both curvature and tissue stiffness significantly impact fluid dynamics. Higher stiffness reduces peak axial velocity, while convex regions exhibit greater velocity and fluid shear stress (FSS) than concave regions. Relative to straight tubules, curvature leads to greater than an order of magnitude decrease in FSS, with concave regions producing the most pronounced suppression. Increased stiffness further decreases wall displacement, reduces von Mises stress, and lowers FSS due to reduced compliance. The relationship between stiffness and FSS suggests that mechanical forces within the tubule microenvironment are strongly influenced by tissue elasticity. As CKD progresses, renal tubules become stiffer, which alters these mechanical forces that further alter fluid dynamics, and contribute to the pathological conditions of the tubule structure. The complex interrelationships among kidney architecture, fluid structure interaction, and pathology highlight the therapeutic importance of taking curvature into account when figuring out how kidney disease progresses and creating tailored treatments.