Jagdeep Sedha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jagdeep Sedha has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Eemu-Samuli Väliaho
Faculty of Medicine, University of Helsinki, Helsinki, Finland
4 shared publications - Helena Jäntti
Department of Anesthesiology and Intensive Care, North Karelia Central Hospital, Joensuu, Finland
4 shared publications - Juha Hartikainen
University of Eastern Finland
4 shared publications - Jukka Antero Lipponen
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
4 shared publications - Noora S. Naukkarinen
School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 8, Kuopio, 70210, Finland, 358 443358523
4 shared publications - Olli Rantula
School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 8, Kuopio, 70210, Finland, 358 443358523
4 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 10, e83714
Deep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory Electrocardiography: Retrospective Diagnostic Accuracy Study
Background: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2% to 4% of the global adult population and is associated with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional electrocardiogram (ECG) interpretation requires substantial expert input and can be challenging, especially with poor-quality ECGs. Objective: This study aimed to evaluate the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including clinical data collected over 6 months at a university hospital, and assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,248 patients, ECG data from our previous studies (648 patients), and authentic long-term ECG recordings from 4346 patients at Kuopio University Hospital for development of the DNN model. Its clinical accuracy and generalizability were assessed using a separate test dataset consisting of 1039 pseudonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.4% sensitivity and more than 99.99% specificity for time-level AF and AFL detection. At the recording level, it identified AF and AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 1.2% (11/897) of recordings, of which 81.8% (9/11) had other non–AF/AFL arrhythmias. The model maintained high performance across diverse patient characteristics, including varying ages, comorbidities, coexisting arrhythmias, and poor-quality ECG recordings. Conclusions: The results demonstrate that the proposed DNN model may support automated screening for AF and AFL in long-term ambulatory ECG recordings and may reduce manual review workload in clinical practice.
- 30 June 2026
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 10, e83714
Open AccessDeep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory Electrocardiography: Retrospective Diagnostic Accuracy Study
Background: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2% to 4% of the global adult population and is associated with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional electrocardiogram (ECG) interpretation requires substantial expert input and can be challenging, especially with poor-quality ECGs. Objective: This study aimed to evaluate the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including clinical data collected over 6 months at a university hospital, and assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,248 patients, ECG data from our previous studies (648 patients), and authentic long-term ECG recordings from 4346 patients at Kuopio University Hospital for development of the DNN model. Its clinical accuracy and generalizability were assessed using a separate test dataset consisting of 1039 pseudonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.4% sensitivity and more than 99.99% specificity for time-level AF and AFL detection. At the recording level, it identified AF and AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 1.2% (11/897) of recordings, of which 81.8% (9/11) had other non–AF/AFL arrhythmias. The model maintained high performance across diverse patient characteristics, including varying ages, comorbidities, coexisting arrhythmias, and poor-quality ECG recordings. Conclusions: The results demonstrate that the proposed DNN model may support automated screening for AF and AFL in long-term ambulatory ECG recordings and may reduce manual review workload in clinical practice.
- Open Access
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e82475
A Deep Neural Network for Interpreting Wearable Electrocardiogram Data in Atrial Fibrillation: Prospective Observational Diagnostic Accuracy Study
Background: Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias associated with the risk of ischemic stroke, which can be reduced with anticoagulation therapy. Thus, early diagnosis of AF and AFL is essential. However, diagnosis may be challenging due to the paroxysmal and asymptomatic nature of these arrhythmias. Objective: Current diagnostic workflows involve time-consuming and resource-intensive manual review of noisy signals and prolonged recordings. We evaluated a mobile system that combines a wireless wearable single-lead chest strap electrocardiogram (ECG) and a novel deep neural network (DNN)–based artificial intelligence (AI) method for detecting AF/AFL episodes, AF/AFL burden, and rhythm change and estimated the delay in the detection of rhythm change from AF/AFL to sinus rhythm. We also assessed the rhythm classification performance. Methods: A total of 116 patients with recent-onset AF or AFL undergoing cardioversion were monitored using a mobile single-lead chest strap ECG system. Simultaneously, a 3-lead Holter ECG served as the reference. The DNN-based AI analyzed the single-lead chest strap ECG data to detect AF/AFL, non-AF/AFLrhythm, and noninterpretable segments, as well as to estimate AF/AFL burden and detect rhythm change. Performance metrics included sensitivity, specificity, positive predictive value, negative predictive value, and intraclass correlation coefficient for AF and AFL burden estimation. Results: The sensitivity and specificity for detecting AF/AFL were 91.9% (204.9/223.0 h) and 99.6% (242.4/243.5 h), respectively. The sensitivity for detecting AF was 96.2% (191.5/199.0 h), whereas it was 55.8% (13.4/24.0 h) for detecting AFL. The positive predictive value and negative predictive value for AF/AFL detection were 99.5% (204.9/206.0 h) and 93.1% (242.4/260.5 h), respectively. The intraclass correlation coefficient between the AF/AFL burden estimated by the DNN-based AI method and that derived from the physician-interpreted reference ECG was 0.96 (95% CI: 0.94‐0.97; P <.001). Rhythm change detection occurred within 1 minute in most cases. Conclusions: The mobile single-lead chest strap ECG system powered by a DNN-based AI algorithm demonstrated strong performance in detecting AF, estimating AF burden, and recognizing rhythm change to sinus rhythm. This AI-driven approach enables automated and accurate rhythm analysis, supporting clinical decision-making. Further validation in real-world ambulatory settings is warranted.
- 23 April 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14 (1) , e82475
Open AccessA Deep Neural Network for Interpreting Wearable Electrocardiogram Data in Atrial Fibrillation: Prospective Observational Diagnostic Accuracy Study
Background: Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias associated with the risk of ischemic stroke, which can be reduced with anticoagulation therapy. Thus, early diagnosis of AF and AFL is essential. However, diagnosis may be challenging due to the paroxysmal and asymptomatic nature of these arrhythmias. Objective: Current diagnostic workflows involve time-consuming and resource-intensive manual review of noisy signals and prolonged recordings. We evaluated a mobile system that combines a wireless wearable single-lead chest strap electrocardiogram (ECG) and a novel deep neural network (DNN)–based artificial intelligence (AI) method for detecting AF/AFL episodes, AF/AFL burden, and rhythm change and estimated the delay in the detection of rhythm change from AF/AFL to sinus rhythm. We also assessed the rhythm classification performance. Methods: A total of 116 patients with recent-onset AF or AFL undergoing cardioversion were monitored using a mobile single-lead chest strap ECG system. Simultaneously, a 3-lead Holter ECG served as the reference. The DNN-based AI analyzed the single-lead chest strap ECG data to detect AF/AFL, non-AF/AFLrhythm, and noninterpretable segments, as well as to estimate AF/AFL burden and detect rhythm change. Performance metrics included sensitivity, specificity, positive predictive value, negative predictive value, and intraclass correlation coefficient for AF and AFL burden estimation. Results: The sensitivity and specificity for detecting AF/AFL were 91.9% (204.9/223.0 h) and 99.6% (242.4/243.5 h), respectively. The sensitivity for detecting AF was 96.2% (191.5/199.0 h), whereas it was 55.8% (13.4/24.0 h) for detecting AFL. The positive predictive value and negative predictive value for AF/AFL detection were 99.5% (204.9/206.0 h) and 93.1% (242.4/260.5 h), respectively. The intraclass correlation coefficient between the AF/AFL burden estimated by the DNN-based AI method and that derived from the physician-interpreted reference ECG was 0.96 (95% CI: 0.94‐0.97; P <.001). Rhythm change detection occurred within 1 minute in most cases. Conclusions: The mobile single-lead chest strap ECG system powered by a DNN-based AI algorithm demonstrated strong performance in detecting AF, estimating AF burden, and recognizing rhythm change to sinus rhythm. This AI-driven approach enables automated and accurate rhythm analysis, supporting clinical decision-making. Further validation in real-world ambulatory settings is warranted.
- Open Access
- 13 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Deep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory ECG: A Diagnostic Accuracy Study (Preprint)
UNSTRUCTURED Background and Aims: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2-4% of the global adult population and is linked with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional ECG interpretation, requiring significant expert input, can be challenging, especially with poor-quality ECGs. This study evaluates the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including real-world clinical data collected over six months at a university hospital. The aim was to assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,896 patients and authentic long-term ECG recordings from 4,346 patients at Kuopio University Hospital for the DNN model’s development. Its clinical accuracy and generalizability were assessed using clinical data and 1039 anonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.35% sensitivity and over 99.99% specificity in time-level AF/AFL detection. At the patient level, it identified AF/AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 11 (1.23%) patients, of which nine had other AF/AFL arrhythmias. The model was highly effective across diverse patient groups, including various ages, comorbidities, other arrhythmias, and poor-quality ECGs. Conclusions: This study showcases the potential of the DNN model to significantly enhance the interpretation of long-term ambulatory ECG recordings, offering an efficient tool for AF/AFL detection, which could decrease manual labor and streamline patient management.
- 13 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDeep Neural Networks for Automatic Atrial Fibrillation Detection Using Long-Term Ambulatory ECG: A Diagnostic Accuracy Study (Preprint)
UNSTRUCTURED Background and Aims: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, affects 2-4% of the global adult population and is linked with an increased risk of stroke. Early diagnosis of AF and atrial flutter (AFL) is crucial due to their association with stroke risk and the challenge posed by their often asymptomatic and episodic nature. Traditional ECG interpretation, requiring significant expert input, can be challenging, especially with poor-quality ECGs. This study evaluates the performance of a deep neural network (DNN) model in detecting AF/AFL from a large, heterogeneous set of long-term ambulatory ECG recordings, including real-world clinical data collected over six months at a university hospital. The aim was to assess its effectiveness in a setting reflecting the diversity and complexity of real-world clinical data. Methods: The research combined public datasets totaling 10,896 patients and authentic long-term ECG recordings from 4,346 patients at Kuopio University Hospital for the DNN model’s development. Its clinical accuracy and generalizability were assessed using clinical data and 1039 anonymized long-term ECG recordings from 1010 patients, all thoroughly reviewed and annotated by experts. Results: The DNN model demonstrated high effectiveness, achieving 96.35% sensitivity and over 99.99% specificity in time-level AF/AFL detection. At the patient level, it identified AF/AFL with 100% sensitivity and 98.77% specificity, producing false positives in only 11 (1.23%) patients, of which nine had other AF/AFL arrhythmias. The model was highly effective across diverse patient groups, including various ages, comorbidities, other arrhythmias, and poor-quality ECGs. Conclusions: This study showcases the potential of the DNN model to significantly enhance the interpretation of long-term ambulatory ECG recordings, offering an efficient tool for AF/AFL detection, which could decrease manual labor and streamline patient management.
- Open Access
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (4) , 723-732
Photoplethysmography in recent-onset atrial fibrillation: automatic detection of rhythm change and burden
Aims: Atrial fibrillation (AF) is the most common arrhythmia, increasing stroke risk. Detecting AF is challenging due to its asymptomatic and paroxysmal nature. This study combines photoplethysmography (PPG) with automated techniques to detect AF, assess AF burden, and monitor rhythm changes from AF to sinus rhythm (SR). Methods and results: Ninety patients with recent-onset (duration <48 h) AF, scheduled for cardioversion, were monitored using a three-channel PPG armband on the upper arm. An ambulatory three-lead electrocardiogram (ECG) served as the gold standard. PPG recordings were segmented into 10-, 20-, 30-, and 60-min detection windows. Automated detection identified SR and AF episodes, rhythm changes, and AF burden. Sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) for rhythm detection were calculated, and the intraclass correlation coefficients (ICCs) for PPG-based AF burden were compared to the gold standard. Monitoring time ranged from 1.0 to 8.2 h per patient. Sensitivities, specificities, PPVs, and NPVs for AF detection were 93.9–94.6, 99.5–99.8, 99.4–99.7, and 93.7–95.0%, respectively. The ICC (0.97–0.98) indicated excellent agreement between PPG and the gold standard in estimating AF burden, with differences of −6.3 to −8.3 min (5.5–6.8%). Rhythm changes from AF to SR were detected in all patients (sensitivity 100%), with detection delays of 4.1 ± 1.4, 8.7 ± 2.8, 13.7 ± 3.9, and 27.8 ± 7.1 min depending on the detection window. Conclusion: Photoplethysmography with automated analysis shows promise in detecting AF, AF burden, and rhythm changes, indicating its potential in AF screening. Clinical trial registration: NCT04917653
- 23 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (4) , 723-732
Open AccessPhotoplethysmography in recent-onset atrial fibrillation: automatic detection of rhythm change and burden
Aims: Atrial fibrillation (AF) is the most common arrhythmia, increasing stroke risk. Detecting AF is challenging due to its asymptomatic and paroxysmal nature. This study combines photoplethysmography (PPG) with automated techniques to detect AF, assess AF burden, and monitor rhythm changes from AF to sinus rhythm (SR). Methods and results: Ninety patients with recent-onset (duration <48 h) AF, scheduled for cardioversion, were monitored using a three-channel PPG armband on the upper arm. An ambulatory three-lead electrocardiogram (ECG) served as the gold standard. PPG recordings were segmented into 10-, 20-, 30-, and 60-min detection windows. Automated detection identified SR and AF episodes, rhythm changes, and AF burden. Sensitivities, specificities, positive predictive values (PPVs), and negative predictive values (NPVs) for rhythm detection were calculated, and the intraclass correlation coefficients (ICCs) for PPG-based AF burden were compared to the gold standard. Monitoring time ranged from 1.0 to 8.2 h per patient. Sensitivities, specificities, PPVs, and NPVs for AF detection were 93.9–94.6, 99.5–99.8, 99.4–99.7, and 93.7–95.0%, respectively. The ICC (0.97–0.98) indicated excellent agreement between PPG and the gold standard in estimating AF burden, with differences of −6.3 to −8.3 min (5.5–6.8%). Rhythm changes from AF to SR were detected in all patients (sensitivity 100%), with detection delays of 4.1 ± 1.4, 8.7 ± 2.8, 13.7 ± 3.9, and 27.8 ± 7.1 min depending on the detection window. Conclusion: Photoplethysmography with automated analysis shows promise in detecting AF, AF burden, and rhythm changes, indicating its potential in AF screening. Clinical trial registration: NCT04917653