Arvind Kumar Sharma
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arvind Kumar Sharma has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Varun Gupta
National Institute of Technology
2 shared publications - Ankur Maheshwari
National Institute of Technology, Hamirpur, Himachal Pradesh, India
1 shared publication - Anshu Gupta
Curtin University
1 shared publication - Karnamadakala Rahul Sharma
Bren School for Environmental Science and Management, University of California, Santa Barbara, CA, USA
1 shared publication - Maneesh Kumar
Department of Hydro & Renewable Energy, Indian Institute of Technology, Roorkee, India
1 shared publication Nivedita Thakur
The Energy and Resources Institute (TERI), Darbari Seth Block, Habitat Place, Lodhi Road, New Delhi-110003, India
1 shared publication
Latest Publications
- 18 June 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
THERMO-ELECTRICAL PERFORMANCE ASSESSMENT OF PHOTOVOLTAIC THERMAL (PVT) SYSTEM USING HYBRID AND MONO-NANOFLUIDS
The objective of the study is to investigate the thermo-electrical performance of photovoltaic thermal (PVT) system under varying volume fraction and mass flow rate (MFR) of various nanofluids such as Cu–water, TiO2–water, and Cu–TiO2–water hybrid nanofluid (HNF) as coolants. An HNF is the combination of different nanoparticles mixed in different proportions in the base fluid. The numerical investigation is carried out on the hourly solar irradiance and ambient temperature data for Ghaziabad city, India (28.6692∘N, 77.4538∘E). The outcome of the investigation shows that the thermo-electrical performance improves significantly as the MFR and volume concentration of nanoparticles in the base fluid increase. Using Cu–TiO2–water nanofluid, the average cell temperature obtained is 33.95∘C, while using TiO2–water nanofluid and Cu-water nanofluid, the average cell temperature is 40.52∘C and 35.68∘C, respectively. The average electrical efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF is 12.91%, 13.34%, and 13.55%, respectively. The average thermal efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF coolant is 34.23%, 38.72%, and 39.76%, respectively. Further, increasing the MFR of HNF from 0.02[ ]kg/s to 0.1[ ]kg/s, the average cell temperature reduces by 9.2%, correspondingly enhancing the electrical efficiency.
- 18 June 2025
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
THERMO-ELECTRICAL PERFORMANCE ASSESSMENT OF PHOTOVOLTAIC THERMAL (PVT) SYSTEM USING HYBRID AND MONO-NANOFLUIDS
The objective of the study is to investigate the thermo-electrical performance of photovoltaic thermal (PVT) system under varying volume fraction and mass flow rate (MFR) of various nanofluids such as Cu–water, TiO2–water, and Cu–TiO2–water hybrid nanofluid (HNF) as coolants. An HNF is the combination of different nanoparticles mixed in different proportions in the base fluid. The numerical investigation is carried out on the hourly solar irradiance and ambient temperature data for Ghaziabad city, India (28.6692∘N, 77.4538∘E). The outcome of the investigation shows that the thermo-electrical performance improves significantly as the MFR and volume concentration of nanoparticles in the base fluid increase. Using Cu–TiO2–water nanofluid, the average cell temperature obtained is 33.95∘C, while using TiO2–water nanofluid and Cu-water nanofluid, the average cell temperature is 40.52∘C and 35.68∘C, respectively. The average electrical efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF is 12.91%, 13.34%, and 13.55%, respectively. The average thermal efficiency obtained using TiO2–water nanofluid, Cu-water nanofluid, and Cu–TiO2–water HNF coolant is 34.23%, 38.72%, and 39.76%, respectively. Further, increasing the MFR of HNF from 0.02[ ]kg/s to 0.1[ ]kg/s, the average cell temperature reduces by 9.2%, correspondingly enhancing the electrical efficiency.
- 2 May 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (4) , 4219-4230
Pre-Processing Based ECG Signal Analysis Using Emerging Tools
The objective of the paper is to count the clear beats (R-peaks or QRS complexes) in the Electrocardiogram (ECG) signal after pre-processing step. Among the three selected techniques, Independent Principal Component Analysis (IPCA), Fractional Fourier Transform (FrFT) and Fractional Wavelet Transform (FrWT) have Sensitivity (Se) of 99.92%, 99.95% and 99.98%, Accuracy (Acc) of 99.88%, 99.93% and 99.96%, Detection Error Rate (DER) of 0.110%, 0.066% and 0.036% along with the disturbance of 2.3%, 2% and 1.7% respectively. The lowest DER in FrWT indicates that it outperforms the IPCA and FrFT. The False Negative plus False Positive (FN + FP) by using the three techniques was 32, 25 and 13 while the output Signal-to-Noise Ratio (SNR) was found to be 24.42, 26.19 and 34.37 dB respectively. These results were figured out on Real Time Database (RT DB). The values of output SNR, Se and Acc were recorded to be 34.37 dB, 99.98% and 99.96% while using FrWT based pre-processing on the data from RT DB. The same technique when used on the data from MIT-BIH arrhythmia Database (MB DB) gave the values of 24.81 dB, 99.96% and 99.93% respectively. It has been observed that all the attributes of the components of ECG signals were preserved when filtered with FrFT. On the other hand, the FrWT segregates the motion artefacts and ECG signal in a better way than FrFT. This is due to the fact that in FrWT decomposition takes place on the signal rotated at a selected angle resulting in less computationally complex decompositions at various levels. It reveals that FrWT retains important biology-related information as the originally recorded ECG signal has.
- 2 May 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (4) , 4219-4230
Pre-Processing Based ECG Signal Analysis Using Emerging Tools
The objective of the paper is to count the clear beats (R-peaks or QRS complexes) in the Electrocardiogram (ECG) signal after pre-processing step. Among the three selected techniques, Independent Principal Component Analysis (IPCA), Fractional Fourier Transform (FrFT) and Fractional Wavelet Transform (FrWT) have Sensitivity (Se) of 99.92%, 99.95% and 99.98%, Accuracy (Acc) of 99.88%, 99.93% and 99.96%, Detection Error Rate (DER) of 0.110%, 0.066% and 0.036% along with the disturbance of 2.3%, 2% and 1.7% respectively. The lowest DER in FrWT indicates that it outperforms the IPCA and FrFT. The False Negative plus False Positive (FN + FP) by using the three techniques was 32, 25 and 13 while the output Signal-to-Noise Ratio (SNR) was found to be 24.42, 26.19 and 34.37 dB respectively. These results were figured out on Real Time Database (RT DB). The values of output SNR, Se and Acc were recorded to be 34.37 dB, 99.98% and 99.96% while using FrWT based pre-processing on the data from RT DB. The same technique when used on the data from MIT-BIH arrhythmia Database (MB DB) gave the values of 24.81 dB, 99.96% and 99.93% respectively. It has been observed that all the attributes of the components of ECG signals were preserved when filtered with FrFT. On the other hand, the FrWT segregates the motion artefacts and ECG signal in a better way than FrFT. This is due to the fact that in FrWT decomposition takes place on the signal rotated at a selected angle resulting in less computationally complex decompositions at various levels. It reveals that FrWT retains important biology-related information as the originally recorded ECG signal has.
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Renewable Energy Technology
- Vol. 7 (3) , 288
Centralised solar charging station for LED lanterns for deployment in Indian rural areas: a design approach
With the ever improving lighting and photovoltaic industries and the initiatives of various solar lighting programs, the market is witnessing a gamut of solar lighting products and delivery models for the same. Besides the widely used stand-alone model, the lighting services of solar lanterns and other portable solar lighting products can be alternatively delivered through charging station models; especially catering to the populace who are unable to purchase standalone models. This paper presents an approach towards designing a central charging station model for solar LED lanterns for rural areas considering the various climatic conditions throughout India, the available technology and the field dynamics. Theoretical design based on the available climatic data is presented followed by the experimental observation at a typical site in one climatic zone as a case. The paper concludes with a discussion on the way-forward towards design and operation improvements for this present model.
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Renewable Energy Technology
- Vol. 7 (3) , 288
Centralised solar charging station for LED lanterns for deployment in Indian rural areas: a design approach
With the ever improving lighting and photovoltaic industries and the initiatives of various solar lighting programs, the market is witnessing a gamut of solar lighting products and delivery models for the same. Besides the widely used stand-alone model, the lighting services of solar lanterns and other portable solar lighting products can be alternatively delivered through charging station models; especially catering to the populace who are unable to purchase standalone models. This paper presents an approach towards designing a central charging station model for solar LED lanterns for rural areas considering the various climatic conditions throughout India, the available technology and the field dynamics. Theoretical design based on the available climatic data is presented followed by the experimental observation at a typical site in one climatic zone as a case. The paper concludes with a discussion on the way-forward towards design and operation improvements for this present model.