Hasitha Damruwan Hidallana-Gamage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hasitha Damruwan Hidallana-Gamage has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chamila Gunasekara
Royal Melbourne Institute of Technology Univ
1 shared publication - David William Law
RMIT University
1 shared publication - Gamini Lanarolle
Faculty of Engineering, University of Moratuwa Department of Textile and Apparel Engineering
1 shared publication - Geeshan Marasinghe
Faculty of Engineering, University of Moratuwa Department of Civil Engineering
1 shared publication - Guomin Zhang
School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
1 shared publication - K.A.P. Wijesinghe
Faculty of Engineering, University of Moratuwa Department of Textile and Apparel Engineering
1 shared publication
Latest Publications
- Open Access
- 17 November 2026
- Published by Emerald Publishing in Smart and Sustainable Built Environment
- p. 1-39
Long-term thermal insulation and acoustic absorption performance of textile fibre-reinforced cement mortars
Purpose: This study aims to develop a sustainable cement mortar incorporating post-industrial textile waste fibres and evaluate long-term performance, together with the underlying mechanisms governing the behaviour. Design/methodology/approach: Waste textile fibres (cotton, polyester, nylon and elastane) were incorporated into cement mortars and evaluated at 28, 90, 180 and 365 days to assess thermal conductivity, sound absorption, compressive strength and drying shrinkage. Microstructural characterisation using scanning electron microscopy (SEM), micro-computed tomography (Micro-CT) and nanoindentation was conducted to investigate microstructure, pore structure and interfacial transition zone (ITZ) behaviour of fibre-reinforced cement mortars (FRMs). A multicriteria decision-making approach based on the Simple Additive Weighting (SAW) method was applied to rank the mix formulations in terms of thermal, acoustic, compressive strength and shrinkage performance. Findings: The overall best-performing ELS FRM achieved the lowest thermal conductivity (0.8 W/mK), around 38% higher average sound absorption than the control, a compressive strength of 49 MPa and approximately 10% lower total shrinkage compared to the control at one-year age. Porosity analysis revealed that ELS FRM exhibited the highest total porosity among all mixes, governed primarily by the high elasticity and fibre geometry of elastane, which can promote air entrapment during mixing and lead to increased internal void content. Despite this porous structure, the high elasticity and deformation compatibility of elastane fibres govern improved stress redistribution and crack-bridging within the matrix, thereby maintaining compressive strength and reducing shrinkage. Originality/value: This research addresses key limitations in existing FRMs by furthering the scarcity of studies extending beyond early ages (7–90 days) and the lack of coupled long-term datasets linking thermal, acoustic, compressive strength and shrinkage performance. In addition, this study develops a clearer understanding of the underlying mechanisms governing performance by addressing the limitation that most existing studies rely on isolated testing ages and SEM observations, without integrated characterisation of microstructure, porosity and ITZ properties. This paves the way for scalable FRM production and practical use in non-load-bearing applications subject to further validation under real exposure conditions.
- 17 November 2026
- Published by Emerald Publishing in Smart and Sustainable Built Environment
- p. 1-39
Open AccessLong-term thermal insulation and acoustic absorption performance of textile fibre-reinforced cement mortars
Purpose: This study aims to develop a sustainable cement mortar incorporating post-industrial textile waste fibres and evaluate long-term performance, together with the underlying mechanisms governing the behaviour. Design/methodology/approach: Waste textile fibres (cotton, polyester, nylon and elastane) were incorporated into cement mortars and evaluated at 28, 90, 180 and 365 days to assess thermal conductivity, sound absorption, compressive strength and drying shrinkage. Microstructural characterisation using scanning electron microscopy (SEM), micro-computed tomography (Micro-CT) and nanoindentation was conducted to investigate microstructure, pore structure and interfacial transition zone (ITZ) behaviour of fibre-reinforced cement mortars (FRMs). A multicriteria decision-making approach based on the Simple Additive Weighting (SAW) method was applied to rank the mix formulations in terms of thermal, acoustic, compressive strength and shrinkage performance. Findings: The overall best-performing ELS FRM achieved the lowest thermal conductivity (0.8 W/mK), around 38% higher average sound absorption than the control, a compressive strength of 49 MPa and approximately 10% lower total shrinkage compared to the control at one-year age. Porosity analysis revealed that ELS FRM exhibited the highest total porosity among all mixes, governed primarily by the high elasticity and fibre geometry of elastane, which can promote air entrapment during mixing and lead to increased internal void content. Despite this porous structure, the high elasticity and deformation compatibility of elastane fibres govern improved stress redistribution and crack-bridging within the matrix, thereby maintaining compressive strength and reducing shrinkage. Originality/value: This research addresses key limitations in existing FRMs by furthering the scarcity of studies extending beyond early ages (7–90 days) and the lack of coupled long-term datasets linking thermal, acoustic, compressive strength and shrinkage performance. In addition, this study develops a clearer understanding of the underlying mechanisms governing performance by addressing the limitation that most existing studies rely on isolated testing ages and SEM observations, without integrated characterisation of microstructure, porosity and ITZ properties. This paves the way for scalable FRM production and practical use in non-load-bearing applications subject to further validation under real exposure conditions.
- 19 June 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Impact of Interlocking Connection on Reliability of Connection Under Extreme-Wind and Earthquake
Inter-modular connections play a critical role in the load sharing. Thus, this study aims to assess the impact of interlocking connections on the reliability indices of modular buildings under extreme loads. Five interlocking and partial interlocking connections were chosen for further analysis under extreme wind and earthquakes for structural reliability analysis of the connections. Fragility curves were developed for connections in axial, shear, and moments based on an analysis of a 10-storey case study modular building. Results showed that partial interlocking connections can safely function at a wind speed 60% higher than that of complete interlocking connections. Moreover, it was identified that partial interlocking connections can withstand a 2.8 times higher peak ground acceleration than a complete interlocking connection under safety limits. Incorporating simple interlocking mechanisms into bolted connections significantly reduces on-site labor time and costs, enhancing reusability while maintaining structural capacities. Further analysis indicated that partial interlocking connections are safe for modular buildings of six to eight storeys under wind speeds of 100[ ]m/s and for buildings up to 10-storeys under earthquakes with magnitudes up to 5. Additionally, reliability index graphs developed for the connections can be referred to in building design or in developing new intermodular connections.
- 19 June 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Impact of Interlocking Connection on Reliability of Connection Under Extreme-Wind and Earthquake
Inter-modular connections play a critical role in the load sharing. Thus, this study aims to assess the impact of interlocking connections on the reliability indices of modular buildings under extreme loads. Five interlocking and partial interlocking connections were chosen for further analysis under extreme wind and earthquakes for structural reliability analysis of the connections. Fragility curves were developed for connections in axial, shear, and moments based on an analysis of a 10-storey case study modular building. Results showed that partial interlocking connections can safely function at a wind speed 60% higher than that of complete interlocking connections. Moreover, it was identified that partial interlocking connections can withstand a 2.8 times higher peak ground acceleration than a complete interlocking connection under safety limits. Incorporating simple interlocking mechanisms into bolted connections significantly reduces on-site labor time and costs, enhancing reusability while maintaining structural capacities. Further analysis indicated that partial interlocking connections are safe for modular buildings of six to eight storeys under wind speeds of 100[ ]m/s and for buildings up to 10-storeys under earthquakes with magnitudes up to 5. Additionally, reliability index graphs developed for the connections can be referred to in building design or in developing new intermodular connections.