Mykola Cherednikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mykola Cherednikov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dmytro Guzyk
National University “Yuri Kondratyuk Poltava Polytechnic
4 shared publications - Oleksandra Cherednikova
Національний університет «Полтавська політехніка імені Юрія Кондратюка
3 shared publications - Volodymyr Cherednikov
Kondratyuk Poltava State Technical University
2 shared publications Микола Чередніков
Харківський національний університет радіоелектроніки
2 shared publications- Artem Kharchenko1 shared publication
- Artem Sosnin1 shared publication
Latest Publications
- Open Access
- 2 January 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 56
Experimental and computer-based analysis of the energy performance of a decentralized ventilation system and indoor environmental quality during the non-heating period
The paper presents the results of a comprehensive experimental and computer-based study of the operation of a decentralized supply and exhaust ventilation unit equipped with a cross-flow plate heat recovery exchanger in an educational classroom during the transitional (non-heating) period in the absence of centralized heating. The objective of the study is a comparative assessment of four operating modes (“Heating”, “Cooling”, “ Auto ”, and “Ventilation”) in terms of energy performance, indoor air quality, and thermal comfort, with the aim of determining the limits of effective system operation. The experimental investigation was carried out in a computer classroom with a total volume of 90.8 m³ under outdoor air temperatures ranging from +3 to +17 °C. Monitoring of air temperatures at characteristic points of the ventilation system, indoor air temperature and relative humidity, as well as CO₂ concentration, was performed at 2–5 minute intervals, followed by aggregation to 10-minute time steps for statistical data processing and further analytical evaluation. The study determined the heat recovery efficiency coefficient (ηrec), the amount of recovered heat (Qrec), and the integral energy efficiency indicator (Eeff), together with thermal comfort parameters PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) calculated in accordance with Fanger’s model. A correlation analysis was conducted to identify relationships between energy and comfort parameters and outdoor air temperature. It was established that with increasing outdoor temperature (tm), the indicators ηrec, Qrec, and Eeff decrease (r = –0.593 to –0.947), which is associated with a reduction in the temperature difference across the heat exchanger. The highest share of comfortable conditions was achieved in the “Auto” mode (approximately 44.7%), whereas operating modes without electric reheating do not ensure acceptable thermal comfort when tm is below +12 °C. Based on the findings, temperature thresholds for the justified use of the electric heater were defined, and practical recommendations for optimizing the control algorithm of ventilation systems in educational buildings during the transitional season were developed.
- 2 January 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 56
Open AccessExperimental and computer-based analysis of the energy performance of a decentralized ventilation system and indoor environmental quality during the non-heating period
The paper presents the results of a comprehensive experimental and computer-based study of the operation of a decentralized supply and exhaust ventilation unit equipped with a cross-flow plate heat recovery exchanger in an educational classroom during the transitional (non-heating) period in the absence of centralized heating. The objective of the study is a comparative assessment of four operating modes (“Heating”, “Cooling”, “ Auto ”, and “Ventilation”) in terms of energy performance, indoor air quality, and thermal comfort, with the aim of determining the limits of effective system operation. The experimental investigation was carried out in a computer classroom with a total volume of 90.8 m³ under outdoor air temperatures ranging from +3 to +17 °C. Monitoring of air temperatures at characteristic points of the ventilation system, indoor air temperature and relative humidity, as well as CO₂ concentration, was performed at 2–5 minute intervals, followed by aggregation to 10-minute time steps for statistical data processing and further analytical evaluation. The study determined the heat recovery efficiency coefficient (ηrec), the amount of recovered heat (Qrec), and the integral energy efficiency indicator (Eeff), together with thermal comfort parameters PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) calculated in accordance with Fanger’s model. A correlation analysis was conducted to identify relationships between energy and comfort parameters and outdoor air temperature. It was established that with increasing outdoor temperature (tm), the indicators ηrec, Qrec, and Eeff decrease (r = –0.593 to –0.947), which is associated with a reduction in the temperature difference across the heat exchanger. The highest share of comfortable conditions was achieved in the “Auto” mode (approximately 44.7%), whereas operating modes without electric reheating do not ensure acceptable thermal comfort when tm is below +12 °C. Based on the findings, temperature thresholds for the justified use of the electric heater were defined, and practical recommendations for optimizing the control algorithm of ventilation systems in educational buildings during the transitional season were developed.
- Open Access
- 26 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 55, 47-65
Comparative analysis of unsteady operating modes of a household air conditioner under normal and insufficient refrigerant charge
The article presents the results of an experimental study of a household air conditioner operating in cooling and heating (heat pump) modes under conditions of normal and insufficient refrigerant charge. The aim of the work is to evaluate the impact of a reduced amount of refrigerant on the thermodynamic parameters of the refrigeration cycle, heating capacity, and energy efficiency of the system. The study was conducted under non-stationary conditions with subsequent analysis of the moment when the unit reaches steady-state operation. During the experiment, the pressure and temperature of the refrigerant were recorded at key points of the cycle: at the compressor outlet, after the condenser, and before and after the throttling device. This made it possible to determine the operating points on the p–h diagram and track enthalpy changes within the system components. Additionally, airflow parameters at the inlet and outlet of the indoor unit — temperature, relative humidity, and velocity — were measured, enabling the assessment of air treatment processes and actual heating capacity in heating mode. The electrical power consumed by the compressor and fans was used for further calculations of energy efficiency based on EER/COP indicators. The results demonstrated that insufficient refrigerant charge leads to reduced evaporation and discharge pressures, increased superheating of the refrigerant vapor, and disruption of the thermal balance of the cycle. Under such conditions, the refrigerant mass flow rate decreases, the heating capacity of the indoor unit is reduced, and the energy efficiency coefficient significantly declines. Moreover, the time required to reach a steady-state regime increases, confirming the instability of system operation under undercharged conditions. The obtained results allow identifying characteristic signs of air-conditioner operation with insufficient refrigerant charge and may be used for diagnosing the technical condition of air-conditioning systems, optimizing maintenance procedures, and improving the energy efficiency of the equipment.
- 26 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 55, 47-65
Open AccessComparative analysis of unsteady operating modes of a household air conditioner under normal and insufficient refrigerant charge
The article presents the results of an experimental study of a household air conditioner operating in cooling and heating (heat pump) modes under conditions of normal and insufficient refrigerant charge. The aim of the work is to evaluate the impact of a reduced amount of refrigerant on the thermodynamic parameters of the refrigeration cycle, heating capacity, and energy efficiency of the system. The study was conducted under non-stationary conditions with subsequent analysis of the moment when the unit reaches steady-state operation. During the experiment, the pressure and temperature of the refrigerant were recorded at key points of the cycle: at the compressor outlet, after the condenser, and before and after the throttling device. This made it possible to determine the operating points on the p–h diagram and track enthalpy changes within the system components. Additionally, airflow parameters at the inlet and outlet of the indoor unit — temperature, relative humidity, and velocity — were measured, enabling the assessment of air treatment processes and actual heating capacity in heating mode. The electrical power consumed by the compressor and fans was used for further calculations of energy efficiency based on EER/COP indicators. The results demonstrated that insufficient refrigerant charge leads to reduced evaporation and discharge pressures, increased superheating of the refrigerant vapor, and disruption of the thermal balance of the cycle. Under such conditions, the refrigerant mass flow rate decreases, the heating capacity of the indoor unit is reduced, and the energy efficiency coefficient significantly declines. Moreover, the time required to reach a steady-state regime increases, confirming the instability of system operation under undercharged conditions. The obtained results allow identifying characteristic signs of air-conditioner operation with insufficient refrigerant charge and may be used for diagnosing the technical condition of air-conditioning systems, optimizing maintenance procedures, and improving the energy efficiency of the equipment.
- Open Access
- 30 October 2025
- Published by Publishing House Helvetica (Publications) in Таврійський науковий вісник. Серія: Технічні науки
- Vol. 1 (4) , 336-349
КОМП’ЮТЕРНІ МЕТОДИ ОЦІНКИ ТЕПЛОВОГО КОМФОРТУ (PMV) З ВИКОРИСТАННЯМ C#-МОДУЛЯ ТА ПОРІВНЯННЯ З АНКЕТНИМИ ДАНИМИ В УМОВАХ НАВЧАЛЬНОГО СЕРЕДОВИЩА
У статті представлено результати дослідження теплового комфорту в умовах навчального середовища на основі поєднання об’єктивних розрахунків індексу PMV (Predicted Mean Vote) та суб’єктивних оцінок користувачів. Для аналітичного визначення PMV було розроблено програмний модуль мовою C#, реалізований згідно з методикою ДСТУ Б EN ISO 7730:2011. Розрахунки здійснено з використанням фактично виміряних параметрів мікроклімату (температура повітря, середня радіаційна температура, швидкість руху повітря, відносна вологість) та даних про теплозахисні властивості одягу й рівень метаболічної активності користувачів. Паралельно було проведено анкетування студентів та викладачів за допомогою стандартизованої форми з 12 запитаннями, що дозволило отримати суб’єктивні оцінки теплового стану та якості повітря. Порівняльний аналіз показав загальну узгодженість між результатами аналітичних розрахунків і даними анкетування. Водночас виявлено окремі розбіжності, зумовлені індивідуальними особливостями користувачів та впливом локальних умов у приміщенні.Результати дослідження підтверджують, що на теплове сприйняття впливають не лише виміряні параметри мікроклімату, а й такі чинники, як тип одягу, фізична активність, адаптація до середовища та суб’єктивні очікування. Особливу увагу приділено аналізу якості повітря, яка є важливим складником загального відчуття комфорту. Запропонований C#-модуль продемонстрував високу точність і стабільність роботи, дозволяючи автоматизувати процес оцінки теплового комфорту та отримувати результати в режимі реального часу. Практичне значення дослідження полягає у можливості використання даного інструменту для моніторингу й оптимізації параметрів мікроклімату в навчальних закладах, що сприятиме підвищенню енергоефективності будівель та створенню сприятливих умов для навчання. Отримані висновки можуть бути корисними для фахівців у галузі енергоменеджменту, проектувальників систем вентиляції та опалення, а також для адміністрацій освітніх установ, зацікавлених у забезпеченні належного теплового комфорту та якості повітря.
- 30 October 2025
- Published by Publishing House Helvetica (Publications) in Таврійський науковий вісник. Серія: Технічні науки
- Vol. 1 (4) , 336-349
Open AccessКОМП’ЮТЕРНІ МЕТОДИ ОЦІНКИ ТЕПЛОВОГО КОМФОРТУ (PMV) З ВИКОРИСТАННЯМ C#-МОДУЛЯ ТА ПОРІВНЯННЯ З АНКЕТНИМИ ДАНИМИ В УМОВАХ НАВЧАЛЬНОГО СЕРЕДОВИЩА
У статті представлено результати дослідження теплового комфорту в умовах навчального середовища на основі поєднання об’єктивних розрахунків індексу PMV (Predicted Mean Vote) та суб’єктивних оцінок користувачів. Для аналітичного визначення PMV було розроблено програмний модуль мовою C#, реалізований згідно з методикою ДСТУ Б EN ISO 7730:2011. Розрахунки здійснено з використанням фактично виміряних параметрів мікроклімату (температура повітря, середня радіаційна температура, швидкість руху повітря, відносна вологість) та даних про теплозахисні властивості одягу й рівень метаболічної активності користувачів. Паралельно було проведено анкетування студентів та викладачів за допомогою стандартизованої форми з 12 запитаннями, що дозволило отримати суб’єктивні оцінки теплового стану та якості повітря. Порівняльний аналіз показав загальну узгодженість між результатами аналітичних розрахунків і даними анкетування. Водночас виявлено окремі розбіжності, зумовлені індивідуальними особливостями користувачів та впливом локальних умов у приміщенні.Результати дослідження підтверджують, що на теплове сприйняття впливають не лише виміряні параметри мікроклімату, а й такі чинники, як тип одягу, фізична активність, адаптація до середовища та суб’єктивні очікування. Особливу увагу приділено аналізу якості повітря, яка є важливим складником загального відчуття комфорту. Запропонований C#-модуль продемонстрував високу точність і стабільність роботи, дозволяючи автоматизувати процес оцінки теплового комфорту та отримувати результати в режимі реального часу. Практичне значення дослідження полягає у можливості використання даного інструменту для моніторингу й оптимізації параметрів мікроклімату в навчальних закладах, що сприятиме підвищенню енергоефективності будівель та створенню сприятливих умов для навчання. Отримані висновки можуть бути корисними для фахівців у галузі енергоменеджменту, проектувальників систем вентиляції та опалення, а також для адміністрацій освітніх установ, зацікавлених у забезпеченні належного теплового комфорту та якості повітря.
- Open Access
- 22 June 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 52, 32-46
Thermal modernization and improvement of engineering systems of campus F of the National University "Yuri Kondratyuk Poltava Polytechnic"
Scientifically based measures for carrying out thermal modernization of a public building, which involve updating microclimate engineering systems by the modern regulatory construction framework, were highlighted in this article. Research is conducted in parallel with the implementation of the "Higher Education of Ukraine" project, which is supported by the European Investment Bank and NEFCO. Implementation of the developed and approved measures for the modernisation of the ventilation, heat supply and heating systems in combination with the insulation of all external envelope structures, according to preliminary calculations, should significantly improve the energy efficiency of the building of the educational building ‘F’. Partial replacement of worn-out heating main pipelines and their complete insulation in accordance with the requirements of DBN B.2.5-67:2013 will reduce heat energy losses for heat transportation, which in turn will reduce heating costs and increase the efficiency of the heating system. Installing an automated individual heat point at the heat network inlet, which consists of a heat meter, a comb, control valves, an electronic controller that controls pumps and control valves depending on indoor and outdoor temperatures, ensures accurate measurement of heat consumption, allows effective adjustment of the operation of the heating system and reduce heating costs. An automatic controller ensures a stable indoor temperature, and the insulation of pipelines helps to avoid additional heat loss. The installation of autonomous ventilation systems with heat recovery in all classrooms and offices that work with CO2 sensors allows for efficient use of electrical energy for ventilation systems, and reduces the cost of heating the supply air through heat recovery.
- 22 June 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 52, 32-46
Open AccessThermal modernization and improvement of engineering systems of campus F of the National University "Yuri Kondratyuk Poltava Polytechnic"
Scientifically based measures for carrying out thermal modernization of a public building, which involve updating microclimate engineering systems by the modern regulatory construction framework, were highlighted in this article. Research is conducted in parallel with the implementation of the "Higher Education of Ukraine" project, which is supported by the European Investment Bank and NEFCO. Implementation of the developed and approved measures for the modernisation of the ventilation, heat supply and heating systems in combination with the insulation of all external envelope structures, according to preliminary calculations, should significantly improve the energy efficiency of the building of the educational building ‘F’. Partial replacement of worn-out heating main pipelines and their complete insulation in accordance with the requirements of DBN B.2.5-67:2013 will reduce heat energy losses for heat transportation, which in turn will reduce heating costs and increase the efficiency of the heating system. Installing an automated individual heat point at the heat network inlet, which consists of a heat meter, a comb, control valves, an electronic controller that controls pumps and control valves depending on indoor and outdoor temperatures, ensures accurate measurement of heat consumption, allows effective adjustment of the operation of the heating system and reduce heating costs. An automatic controller ensures a stable indoor temperature, and the insulation of pipelines helps to avoid additional heat loss. The installation of autonomous ventilation systems with heat recovery in all classrooms and offices that work with CO2 sensors allows for efficient use of electrical energy for ventilation systems, and reduces the cost of heating the supply air through heat recovery.