Volodymyr Cherednikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Volodymyr Cherednikov has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Oleksandra Cherednikova
Національний університет «Полтавська політехніка імені Юрія Кондратюка
6 shared publications A. V. Gorik
Yu. Kondratyuk Poltava State Technical University
4 shared publications- Dmytro Guzyk
National University “Yuri Kondratyuk Poltava Polytechnic
4 shared publications V. G. Piskunov
National Academy of Sciences of Ukraine
4 shared publications- Mykola Cherednikov
Харківський національний університет радіоелектроніки
2 shared publications A .V. Gorik
Yuri Kondratyuk State Technical University
1 shared publication
Latest Publications
- Open Access
- 30 October 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 58, 49-61
Determination of the required airflow rate and operating modes of the VUT300 heat recovery unit based on CO₂ concentration in a university classroom
The paper presents the results of field measurements of carbon dioxide (CO₂) concentration in classroom 107Ts of Poltava Polytechnic National University, equipped with a decentralized supply-and-exhaust heat recovery unit VUT300 with three fixed fan speeds. The study aimed to establish the dependence of indoor CO₂ concentration on the number of occupants and the fan speed of the recovery unit, and to determine the minimum required outdoor airflow rate per person that keeps the CO₂ increment within the commonly accepted limit of 800 ppm above the outdoor background level. Measurements were carried out using three multifunctional Xintest HT-501 sensors, recording CO₂ concentration, relative humidity and temperature every two minutes at three characteristic points of the room: in the breathing zone at the center of the classroom, near the supply air branch, and in the most remote 'dead zone' with respect to the supply airflow. Outdoor conditions were monitored with a Sencor SWS 12500 WIFI weather station installed on the roof, and the electric power consumption of the unit at each fan speed was measured with a Sonoff POWR316D WIFI energy meter. Duct airflow rates in the 160 mm supply and exhaust ducts were additionally verified with a testo 405 V1 hot-wire anemometer with a telescopic probe, yielding measured supply airflow rates of approximately 70, 206 and 275 m³/h for the first, second and third fan speeds, respectively. An initial series of measurements under freely varying occupancy (0 to 8 people) did not produce a conclusive relationship between occupancy and CO₂ concentration because of fluctuations in the number of people present during the class. Therefore, a second series with strictly fixed occupancy before and after a defined time interval was used to determine the per-person CO₂ generation rate by applying a CO₂ mass-balance (build-up) method. The resulting generation rate of approximately 0.0036 dm³/s (12.95 dm³/h) per person is consistent with physiologically based estimates reported in the literature. Based on this rate, the required outdoor airflow was calculated for 1 to 20 occupants, and the applicability ranges of the three fan speeds of the VUT300 unit were established: the first speed is sufficient for 1-4 people, the second for 5-12 people, and the third for 13-16 people; for 17 or more people the measured capacity of the unit is insufficient to keep the CO₂ increment within the target limit under real operating conditions. The calculated values were compared with the normative outdoor airflow rates prescribed by DBN V.2.2-3:2018 'Educational Institutions' (20 m³/(h·person)) and with the category-based approach of DSTU B EN 15251:2011, showing that normative values include a margin beyond pure metabolic CO₂ control, since they also account for other human bioeffluents and perceived air quality criteria. The obtained results provide a practical basis for scheduling the fan speed of classroom heat recovery units (for example, through the Vents Home application) according to the expected number of students in a group, allowing indoor air quality requirements to be reconciled with energy-efficient operation of ventilation equipment during the ongoing thermal modernization of university buildings. The proposed approach can be extended to other classrooms and recovery unit models, and combined with direct CO₂-based automatic fan speed control instead of schedule-only operation, as a direction for further research.
- 30 October 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 58, 49-61
Open AccessDetermination of the required airflow rate and operating modes of the VUT300 heat recovery unit based on CO₂ concentration in a university classroom
The paper presents the results of field measurements of carbon dioxide (CO₂) concentration in classroom 107Ts of Poltava Polytechnic National University, equipped with a decentralized supply-and-exhaust heat recovery unit VUT300 with three fixed fan speeds. The study aimed to establish the dependence of indoor CO₂ concentration on the number of occupants and the fan speed of the recovery unit, and to determine the minimum required outdoor airflow rate per person that keeps the CO₂ increment within the commonly accepted limit of 800 ppm above the outdoor background level. Measurements were carried out using three multifunctional Xintest HT-501 sensors, recording CO₂ concentration, relative humidity and temperature every two minutes at three characteristic points of the room: in the breathing zone at the center of the classroom, near the supply air branch, and in the most remote 'dead zone' with respect to the supply airflow. Outdoor conditions were monitored with a Sencor SWS 12500 WIFI weather station installed on the roof, and the electric power consumption of the unit at each fan speed was measured with a Sonoff POWR316D WIFI energy meter. Duct airflow rates in the 160 mm supply and exhaust ducts were additionally verified with a testo 405 V1 hot-wire anemometer with a telescopic probe, yielding measured supply airflow rates of approximately 70, 206 and 275 m³/h for the first, second and third fan speeds, respectively. An initial series of measurements under freely varying occupancy (0 to 8 people) did not produce a conclusive relationship between occupancy and CO₂ concentration because of fluctuations in the number of people present during the class. Therefore, a second series with strictly fixed occupancy before and after a defined time interval was used to determine the per-person CO₂ generation rate by applying a CO₂ mass-balance (build-up) method. The resulting generation rate of approximately 0.0036 dm³/s (12.95 dm³/h) per person is consistent with physiologically based estimates reported in the literature. Based on this rate, the required outdoor airflow was calculated for 1 to 20 occupants, and the applicability ranges of the three fan speeds of the VUT300 unit were established: the first speed is sufficient for 1-4 people, the second for 5-12 people, and the third for 13-16 people; for 17 or more people the measured capacity of the unit is insufficient to keep the CO₂ increment within the target limit under real operating conditions. The calculated values were compared with the normative outdoor airflow rates prescribed by DBN V.2.2-3:2018 'Educational Institutions' (20 m³/(h·person)) and with the category-based approach of DSTU B EN 15251:2011, showing that normative values include a margin beyond pure metabolic CO₂ control, since they also account for other human bioeffluents and perceived air quality criteria. The obtained results provide a practical basis for scheduling the fan speed of classroom heat recovery units (for example, through the Vents Home application) according to the expected number of students in a group, allowing indoor air quality requirements to be reconciled with energy-efficient operation of ventilation equipment during the ongoing thermal modernization of university buildings. The proposed approach can be extended to other classrooms and recovery unit models, and combined with direct CO₂-based automatic fan speed control instead of schedule-only operation, as a direction for further research.
- Open Access
- 2 January 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 56
Experimental and computer-based analysis of the energy performance of a decentralized ventilation system and indoor environmental quality during the non-heating period
The paper presents the results of a comprehensive experimental and computer-based study of the operation of a decentralized supply and exhaust ventilation unit equipped with a cross-flow plate heat recovery exchanger in an educational classroom during the transitional (non-heating) period in the absence of centralized heating. The objective of the study is a comparative assessment of four operating modes (“Heating”, “Cooling”, “ Auto ”, and “Ventilation”) in terms of energy performance, indoor air quality, and thermal comfort, with the aim of determining the limits of effective system operation. The experimental investigation was carried out in a computer classroom with a total volume of 90.8 m³ under outdoor air temperatures ranging from +3 to +17 °C. Monitoring of air temperatures at characteristic points of the ventilation system, indoor air temperature and relative humidity, as well as CO₂ concentration, was performed at 2–5 minute intervals, followed by aggregation to 10-minute time steps for statistical data processing and further analytical evaluation. The study determined the heat recovery efficiency coefficient (ηrec), the amount of recovered heat (Qrec), and the integral energy efficiency indicator (Eeff), together with thermal comfort parameters PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) calculated in accordance with Fanger’s model. A correlation analysis was conducted to identify relationships between energy and comfort parameters and outdoor air temperature. It was established that with increasing outdoor temperature (tm), the indicators ηrec, Qrec, and Eeff decrease (r = –0.593 to –0.947), which is associated with a reduction in the temperature difference across the heat exchanger. The highest share of comfortable conditions was achieved in the “Auto” mode (approximately 44.7%), whereas operating modes without electric reheating do not ensure acceptable thermal comfort when tm is below +12 °C. Based on the findings, temperature thresholds for the justified use of the electric heater were defined, and practical recommendations for optimizing the control algorithm of ventilation systems in educational buildings during the transitional season were developed.
- 2 January 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 56
Open AccessExperimental and computer-based analysis of the energy performance of a decentralized ventilation system and indoor environmental quality during the non-heating period
The paper presents the results of a comprehensive experimental and computer-based study of the operation of a decentralized supply and exhaust ventilation unit equipped with a cross-flow plate heat recovery exchanger in an educational classroom during the transitional (non-heating) period in the absence of centralized heating. The objective of the study is a comparative assessment of four operating modes (“Heating”, “Cooling”, “ Auto ”, and “Ventilation”) in terms of energy performance, indoor air quality, and thermal comfort, with the aim of determining the limits of effective system operation. The experimental investigation was carried out in a computer classroom with a total volume of 90.8 m³ under outdoor air temperatures ranging from +3 to +17 °C. Monitoring of air temperatures at characteristic points of the ventilation system, indoor air temperature and relative humidity, as well as CO₂ concentration, was performed at 2–5 minute intervals, followed by aggregation to 10-minute time steps for statistical data processing and further analytical evaluation. The study determined the heat recovery efficiency coefficient (ηrec), the amount of recovered heat (Qrec), and the integral energy efficiency indicator (Eeff), together with thermal comfort parameters PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) calculated in accordance with Fanger’s model. A correlation analysis was conducted to identify relationships between energy and comfort parameters and outdoor air temperature. It was established that with increasing outdoor temperature (tm), the indicators ηrec, Qrec, and Eeff decrease (r = –0.593 to –0.947), which is associated with a reduction in the temperature difference across the heat exchanger. The highest share of comfortable conditions was achieved in the “Auto” mode (approximately 44.7%), whereas operating modes without electric reheating do not ensure acceptable thermal comfort when tm is below +12 °C. Based on the findings, temperature thresholds for the justified use of the electric heater were defined, and practical recommendations for optimizing the control algorithm of ventilation systems in educational buildings during the transitional season were developed.
- Open Access
- 26 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 55, 47-65
Comparative analysis of unsteady operating modes of a household air conditioner under normal and insufficient refrigerant charge
The article presents the results of an experimental study of a household air conditioner operating in cooling and heating (heat pump) modes under conditions of normal and insufficient refrigerant charge. The aim of the work is to evaluate the impact of a reduced amount of refrigerant on the thermodynamic parameters of the refrigeration cycle, heating capacity, and energy efficiency of the system. The study was conducted under non-stationary conditions with subsequent analysis of the moment when the unit reaches steady-state operation. During the experiment, the pressure and temperature of the refrigerant were recorded at key points of the cycle: at the compressor outlet, after the condenser, and before and after the throttling device. This made it possible to determine the operating points on the p–h diagram and track enthalpy changes within the system components. Additionally, airflow parameters at the inlet and outlet of the indoor unit — temperature, relative humidity, and velocity — were measured, enabling the assessment of air treatment processes and actual heating capacity in heating mode. The electrical power consumed by the compressor and fans was used for further calculations of energy efficiency based on EER/COP indicators. The results demonstrated that insufficient refrigerant charge leads to reduced evaporation and discharge pressures, increased superheating of the refrigerant vapor, and disruption of the thermal balance of the cycle. Under such conditions, the refrigerant mass flow rate decreases, the heating capacity of the indoor unit is reduced, and the energy efficiency coefficient significantly declines. Moreover, the time required to reach a steady-state regime increases, confirming the instability of system operation under undercharged conditions. The obtained results allow identifying characteristic signs of air-conditioner operation with insufficient refrigerant charge and may be used for diagnosing the technical condition of air-conditioning systems, optimizing maintenance procedures, and improving the energy efficiency of the equipment.
- 26 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 55, 47-65
Open AccessComparative analysis of unsteady operating modes of a household air conditioner under normal and insufficient refrigerant charge
The article presents the results of an experimental study of a household air conditioner operating in cooling and heating (heat pump) modes under conditions of normal and insufficient refrigerant charge. The aim of the work is to evaluate the impact of a reduced amount of refrigerant on the thermodynamic parameters of the refrigeration cycle, heating capacity, and energy efficiency of the system. The study was conducted under non-stationary conditions with subsequent analysis of the moment when the unit reaches steady-state operation. During the experiment, the pressure and temperature of the refrigerant were recorded at key points of the cycle: at the compressor outlet, after the condenser, and before and after the throttling device. This made it possible to determine the operating points on the p–h diagram and track enthalpy changes within the system components. Additionally, airflow parameters at the inlet and outlet of the indoor unit — temperature, relative humidity, and velocity — were measured, enabling the assessment of air treatment processes and actual heating capacity in heating mode. The electrical power consumed by the compressor and fans was used for further calculations of energy efficiency based on EER/COP indicators. The results demonstrated that insufficient refrigerant charge leads to reduced evaporation and discharge pressures, increased superheating of the refrigerant vapor, and disruption of the thermal balance of the cycle. Under such conditions, the refrigerant mass flow rate decreases, the heating capacity of the indoor unit is reduced, and the energy efficiency coefficient significantly declines. Moreover, the time required to reach a steady-state regime increases, confirming the instability of system operation under undercharged conditions. The obtained results allow identifying characteristic signs of air-conditioner operation with insufficient refrigerant charge and may be used for diagnosing the technical condition of air-conditioning systems, optimizing maintenance procedures, and improving the energy efficiency of the equipment.
- Open Access
- 12 May 2022
- Published by Ukrainian State University of Railway Transport in Collection of scientific works of the Ukrainian State University of Railway Transport
- No. 198,p. 66-81
MODELING, DESIGN AND TESTING TO INCREASE THE EFFICIENCY OF THE HELICOPER INTERNAL COMBUSTION ENGINE COOLING SYSTEM
During the operation of the helicopter in tropical climate (African countries) showedthat the water cooling system of the helicopter engine was worked inefficiently in the hover mode or athigh outdoor temperatures. Inefficiency is a limitation of hovering time or time of horizontal flight. Asa result, the flight had to be interrupted due to heating of the engine to a critical temperature. In orderto safely operate the helicopter in conditions of heightened air temperatures, it was necessary toupgrade the engine cooling system.In the article, the sequence of 3D modeling, design and testing of the cooling system of theinternal combustion engine (ICE) of a helicopter is presented with the aim of increasing the limits ofits application in countries with a tropical climate. The main purpose was obtaining more efficientcooling system of the ICE by increasing in heat removal from it. It was done constructively byincreasing the air flow through the radiator by more powerful fans with efficient blades and by usingof a radiator with high heat transfer. Based on the availability of cooling system components in themodern market, two variants of its design solution were proposed.The creation of a new cooling system went in two stages: a preliminary design and a prototype(working design) for two design options: the first cooling system with TEMIC fans and the secondcooling system with SPAL fans. At the first stage, the possibility of installing these systems on ahelicopter was determined, and in the second stage, detailed 3D modeling was created to makeworking drawings. After the production of variants of the new cooling system and their installation onhelicoptersю. The next step the testing were consisted of 3 stages: verification of the efficiency andeffectiveness of the variants of the new cooling system; determination of the maximum coolingcapacity of variants of the new cooling system; checking the efficiency and functionality of theautomatic engine temperature control unit.The most effective of both options was found by the results of their modeling, design and testing.Subsequently, it version of the cooling system was applied to the helicopter. That allowed increasingthe upper limit of operating temperatures to plus 45˚C.
- 12 May 2022
- Published by Ukrainian State University of Railway Transport in Collection of scientific works of the Ukrainian State University of Railway Transport
- No. 198,p. 66-81
Open AccessMODELING, DESIGN AND TESTING TO INCREASE THE EFFICIENCY OF THE HELICOPER INTERNAL COMBUSTION ENGINE COOLING SYSTEM
During the operation of the helicopter in tropical climate (African countries) showedthat the water cooling system of the helicopter engine was worked inefficiently in the hover mode or athigh outdoor temperatures. Inefficiency is a limitation of hovering time or time of horizontal flight. Asa result, the flight had to be interrupted due to heating of the engine to a critical temperature. In orderto safely operate the helicopter in conditions of heightened air temperatures, it was necessary toupgrade the engine cooling system.In the article, the sequence of 3D modeling, design and testing of the cooling system of theinternal combustion engine (ICE) of a helicopter is presented with the aim of increasing the limits ofits application in countries with a tropical climate. The main purpose was obtaining more efficientcooling system of the ICE by increasing in heat removal from it. It was done constructively byincreasing the air flow through the radiator by more powerful fans with efficient blades and by usingof a radiator with high heat transfer. Based on the availability of cooling system components in themodern market, two variants of its design solution were proposed.The creation of a new cooling system went in two stages: a preliminary design and a prototype(working design) for two design options: the first cooling system with TEMIC fans and the secondcooling system with SPAL fans. At the first stage, the possibility of installing these systems on ahelicopter was determined, and in the second stage, detailed 3D modeling was created to makeworking drawings. After the production of variants of the new cooling system and their installation onhelicoptersю. The next step the testing were consisted of 3 stages: verification of the efficiency andeffectiveness of the variants of the new cooling system; determination of the maximum coolingcapacity of variants of the new cooling system; checking the efficiency and functionality of theautomatic engine temperature control unit.The most effective of both options was found by the results of their modeling, design and testing.Subsequently, it version of the cooling system was applied to the helicopter. That allowed increasingthe upper limit of operating temperatures to plus 45˚C.
- 1 January 2022
- Published by Publishing House Helvetica (Publications) in Scientific notes of Taurida National V.I. Vernadsky University. Series: Technical Sciences
- No. 5,p. 228-235
PREPARATION FOR TESTS WITH THE CREATION OF A PROGRAM FOR DETERMINING THE CHARACTERISTICS OF HELICOPTER INTERNAL COMBUSTION ENGINES ON THE LABORATORY STAND
- 1 January 2022
- Published by Publishing House Helvetica (Publications) in Scientific notes of Taurida National V.I. Vernadsky University. Series: Technical Sciences
- No. 5,p. 228-235
PREPARATION FOR TESTS WITH THE CREATION OF A PROGRAM FOR DETERMINING THE CHARACTERISTICS OF HELICOPTER INTERNAL COMBUSTION ENGINES ON THE LABORATORY STAND
- Open Access
- 6 December 2021
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 39, 53-60
Testing the cooling system of the helicopter internal combustion engine in hot climates
У статті ставиться питання необхідності вирішення проблеми розширення температурних меж роботи системи охолодження двигуна внутрішнього згорання гелікоптера. Дане питання виникло з того, що при експлуатації гелікоптера на території африканських країн з спекотним кліматом відбувався перегрів двигуна. Питання використання гелікоптерів в цих умовах було обумовлено попитом на авіаційному ринку. Для розв’язання поставленої задачі був проведений вибір нових елементів системи охолодження, а саме радіатора та двох типів вентиляторів. Дослідження були направлені на збільшення тепловіддачі радіаторів системи охолодження шляхом збільшення типорозміру радіатора та збільшення швидкості повітряного потоку, який проходив крізь радіатор. Виконувалось 3D моделювання, проєктування нової системи охолодження (СО), а потім і конструювання СО в двох варіантах з вентиляторами TEMIC та SPAL. Два дослідних зразка пройшли наземні та льотні випробування спочатку в умовах помірного клімату, де був виявлений зразок з найкращими параметрами роботи. Для льотних випробувань в умовах з жарким кліматом була використана нова система охолодження з вентилятором SPAL, ці випробування тривали три дні. Дана стаття описує завершальний етап серії випробувань ефективності системи охолодження гелікоптера та аналіз отриманих результатів з підтвердженням остаточного досягнення поставленої мети, тобто підвищення верхньої температурної межі зовнішнього повітря для безперебійної та безпечної роботи гелікоптера.
- 6 December 2021
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 39, 53-60
Open AccessTesting the cooling system of the helicopter internal combustion engine in hot climates
У статті ставиться питання необхідності вирішення проблеми розширення температурних меж роботи системи охолодження двигуна внутрішнього згорання гелікоптера. Дане питання виникло з того, що при експлуатації гелікоптера на території африканських країн з спекотним кліматом відбувався перегрів двигуна. Питання використання гелікоптерів в цих умовах було обумовлено попитом на авіаційному ринку. Для розв’язання поставленої задачі був проведений вибір нових елементів системи охолодження, а саме радіатора та двох типів вентиляторів. Дослідження були направлені на збільшення тепловіддачі радіаторів системи охолодження шляхом збільшення типорозміру радіатора та збільшення швидкості повітряного потоку, який проходив крізь радіатор. Виконувалось 3D моделювання, проєктування нової системи охолодження (СО), а потім і конструювання СО в двох варіантах з вентиляторами TEMIC та SPAL. Два дослідних зразка пройшли наземні та льотні випробування спочатку в умовах помірного клімату, де був виявлений зразок з найкращими параметрами роботи. Для льотних випробувань в умовах з жарким кліматом була використана нова система охолодження з вентилятором SPAL, ці випробування тривали три дні. Дана стаття описує завершальний етап серії випробувань ефективності системи охолодження гелікоптера та аналіз отриманих результатів з підтвердженням остаточного досягнення поставленої мети, тобто підвищення верхньої температурної межі зовнішнього повітря для безперебійної та безпечної роботи гелікоптера.
- 23 January 2017
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 61 (3) , 483-490
Evaluation of the Warping Model for Analysis of Polystyrene Concrete Slabs with Profiled Steel Sheeting
In this article the possibility of applying the warping model offered by V. G. Piskunov, A. V. Goryk and V. N. Cherednikov for analyzing polystyrene concrete slabs with profiled steel sheeting is considered. The adequacy of the offered model was verified by comparing the experimental and calculated deflections of the slab. Test specimens of polystyrene concrete slabs with profiled steel sheeting (PCSPSS) were made for experimental studies and then mechanical properties of the slab components – the polystyrene concrete and the profiled steel sheeting – were determined. Then the behaviour of slabs under a load was studied. The calculation of the warping model of PCSPSS was done at the same time. The obtained results have proved the possibility of applying of the offered warping model for analysis of PCSPSS. It is proposed to use the considered model for further study of the stress-strained state of inhomogeneous slabs.
- 23 January 2017
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 61 (3) , 483-490
Evaluation of the Warping Model for Analysis of Polystyrene Concrete Slabs with Profiled Steel Sheeting
In this article the possibility of applying the warping model offered by V. G. Piskunov, A. V. Goryk and V. N. Cherednikov for analyzing polystyrene concrete slabs with profiled steel sheeting is considered. The adequacy of the offered model was verified by comparing the experimental and calculated deflections of the slab. Test specimens of polystyrene concrete slabs with profiled steel sheeting (PCSPSS) were made for experimental studies and then mechanical properties of the slab components – the polystyrene concrete and the profiled steel sheeting – were determined. Then the behaviour of slabs under a load was studied. The calculation of the warping model of PCSPSS was done at the same time. The obtained results have proved the possibility of applying of the offered warping model for analysis of PCSPSS. It is proposed to use the considered model for further study of the stress-strained state of inhomogeneous slabs.
- 1 November 2001
- Published by Springer Nature in Strength of Materials
- Vol. 33 (6) , 526-534
Experimental and Theoretical Studies on the Nonlinear Stress-Strain State of a Laminated Ceramic Composite
- 1 November 2001
- Published by Springer Nature in Strength of Materials
- Vol. 33 (6) , 526-534
Experimental and Theoretical Studies on the Nonlinear Stress-Strain State of a Laminated Ceramic Composite
- 1 November 2000
- Published by Springer Nature in Mechanics of Composite Materials
- Vol. 36 (6) , 445-452
Modeling of Transverse Shears of Piecewise Homogeneous Composite Bars Using an Iterative Process with Account of Tangential Loads. 2. Resolving Equations and Results
- 1 November 2000
- Published by Springer Nature in Mechanics of Composite Materials
- Vol. 36 (6) , 445-452
Modeling of Transverse Shears of Piecewise Homogeneous Composite Bars Using an Iterative Process with Account of Tangential Loads. 2. Resolving Equations and Results
- 1 May 2000
- Published by Springer Nature in Strength of Materials
- Vol. 32 (3) , 262-269
Theoretical and experimental investigation of bending of sandwich beams
- 1 May 2000
- Published by Springer Nature in Strength of Materials
- Vol. 32 (3) , 262-269
Theoretical and experimental investigation of bending of sandwich beams