WGWenxiang Guo

Wenxiang Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenxiang Guo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Path-integral calculation of the second and third density virial coefficients of 4He

    by Wenxiang Guo, Haiyang Zhang, Mingyu Su, Bo Gao

    We present a comprehensive study of the second and third density virial coefficients, B(T) and C(T), of 4He across an extended temperature range from 1 K to 10 000 K, utilizing the path-integral Monte Carlo (PIMC) method and the most accurate interaction potentials. This work reports the first complete determination of B(T) within the PIMC framework, demonstrating excellent agreement and comparable uncertainties with results from the established phase-shift method, thus providing crucial cross-method validation. We generate a significantly extended and high-accuracy dataset for C(T), complementing existing literature values. A comprehensive uncertainty analysis quantifies contributions from both two-body and three-body potentials. The results reveal subtle differences from previous work for C(T) below 5 K, while reducing the uncertainty by approximately a factor of two in this low-temperature regime. This study provides crucial reference data to enhance the accuracy of primary standards for both temperature and pressure based on 4He.


  • Open Access

    Comparison of PLTS-2000 and the magnetic field fluctuation thermometer at LNE-Cnam

    by C Tauzin, M D Plimmer, F Sparasci, W Guo, R White, L Pitre

    This paper presents a comparison between the provisional low-temperature scale of 2000 (PLTS-2000) and the magnetic field fluctuation thermometer (MFFT) scales, as realized at LNE-Cnam. The comparison was carried out using three different realizations (i.e. different melting pressure sensors) of PLTS-2000 and a magnetic field fluctuation thermometer operated with a long measurement time (about 3 h) and a more precise power spectral density model of the MFFT response that included an offset term to account for the background noise in the MFFT electronics. The comparison over the range between 8 mK and 1 K shows that the PLTS- 2000 and MFFT scales agree within about 0.2 mK. The results confirm the thermodynamic accuracy of PLTS-2000 at the same level of uncertainty, and show that, under suitable conditions, MFFT measurements can achieve comparable performance. This highlights its potential use in certain practical applications where direct realization of PLTS-2000 is not feasible.