YGYanxin Gu

Yanxin Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanxin Gu has a total of 1 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis on the Influence of the Active Power Recovery Rate on the Transient Stability Margin of a New Power System

    by Yanxin Gu, Yibo Zhou

    With the large-scale integration of wind power, transient stability issues in power systems have become increasingly prominent, among which the impact of the active power recovery rate of wind turbines on system stability cannot be ignored. This paper establishes a sensitivity analytical model between the transient stability index of the system and the active power recovery rate of doubly fed induction generators (DFIGs), revealing the influence of active power recovery rate on system stability. First, the trajectory analysis method is adopted as the transient stability assessment approach, proposing a stability index incorporating accelerating power and transient potential energy. Analytical sensitivity models for synchronous generator accelerating power and transient potential energy to the active power recovery rate of wind turbines are derived in a simplified system. Second, a sensitivity model of the stability margin index to the active power recovery rate is constructed to analyze the influence patterns of the active power recovery rate, initial active power output of wind turbines, and fault duration time on system stability. This research demonstrates that: accelerating the active power recovery rate can restore power balance more quickly but it reduces the rate of transient potential energy variation and delays the peak response of potential energy, thereby decreasing the stability margin; higher initial active power output of wind turbines suppresses the oscillation amplitude of synchronous generators but increases the risk of power imbalance; and prolonged fault duration exacerbates transient energy accumulation and significantly degrades system stability. Additionally, for each 0.1 p.u./s increase in the active power recovery rate of the wind turbine, the absolute value of the stability index of the synchronous machine in the single-machine system decreases by approximately 0.5–1.0, while the sensitivity decreases by approximately 0.01–0.02 s−1. In the multi-machine system, the absolute value of the stability index of the critical machine decreases by approximately 5–10, and the sensitivity decreases by approximately 0.5–1.0 s−1.