Xueru Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xueru Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Jun Shen
Department of Orthopaedic Surgery, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China
2 shared publications- Weiwei Shao
Chinese Academy of Sciences Suzhou Institute of Biomedical Engineering and Technology, Suzhou, China
2 shared publications - Jiaqi Li
School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, China
1 shared publication - Xiangxin Li
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China
1 shared publication - Yang Jiao
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
1 shared publication Yaoyao Cui
Chinese Academy of Sciences Suzhou Institute of Biomedical Engineering and Technology, Suzhou, China
1 shared publication
Latest Publications
- 28 September 2026
- Published by Elsevier in Ultrasonics
- Vol. 170, 108322
A hybrid simulation phase correction method for endoscopic trans-osseous ultrasound imaging
- 28 September 2026
- Published by Elsevier in Ultrasonics
- Vol. 170, 108322
A hybrid simulation phase correction method for endoscopic trans-osseous ultrasound imaging
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (4) , 467-478
Patch Fusion: A Novel Ultrafast Multi-Frequency Ultrasound Fusion Imaging Method for Pedicle Screw Navigation
Intraosseous ultrasound imaging is valuable for guiding pedicle screw placement in surgery. However, single-frequency ultrasound, whether low or high, often fails to provide both adequate imaging resolution and depth simultaneously. To address this limitation, we introduce a novel ultrafast multi-frequency ultrasound patch fusion imaging method for pedicle screw navigation. This approach combines the strengths of both high-frequency and low-frequency ultrasound images, greatly enhancing the detail and clarity of the resulting images while significantly reducing the time required for image fusion. We validated our method through simulation and ex-vivo experiments, using metrics such as Information Entropy (IE), Spatial Frequency (SF), and Average Gradient (AG) to assess the quality of the fused images. We also recorded the algorithm’s execution time. The results demonstrate that our fusion method substantially improves image richness and clarity, enabling a more comprehensive and accurate assessment of the pedicle screw track. Importantly, it also reduces fusion time compared to previous methods, making real-time clinical multi-frequency ultrasound fusion imaging a viable possibility. The in-vivo experimental results of the sheep spinal pedicle screw track further demonstrate the capabilities of the patch fusion method in visualizing the internal conditions of the pedicle screw track and meeting the requirements for real-time fusion imaging. The proposed approach offers substantial support in surgical real-time navigation and ongoing monitoring within the domains of orthopedics and surgery.
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (4) , 467-478
Patch Fusion: A Novel Ultrafast Multi-Frequency Ultrasound Fusion Imaging Method for Pedicle Screw Navigation
Intraosseous ultrasound imaging is valuable for guiding pedicle screw placement in surgery. However, single-frequency ultrasound, whether low or high, often fails to provide both adequate imaging resolution and depth simultaneously. To address this limitation, we introduce a novel ultrafast multi-frequency ultrasound patch fusion imaging method for pedicle screw navigation. This approach combines the strengths of both high-frequency and low-frequency ultrasound images, greatly enhancing the detail and clarity of the resulting images while significantly reducing the time required for image fusion. We validated our method through simulation and ex-vivo experiments, using metrics such as Information Entropy (IE), Spatial Frequency (SF), and Average Gradient (AG) to assess the quality of the fused images. We also recorded the algorithm’s execution time. The results demonstrate that our fusion method substantially improves image richness and clarity, enabling a more comprehensive and accurate assessment of the pedicle screw track. Importantly, it also reduces fusion time compared to previous methods, making real-time clinical multi-frequency ultrasound fusion imaging a viable possibility. The in-vivo experimental results of the sheep spinal pedicle screw track further demonstrate the capabilities of the patch fusion method in visualizing the internal conditions of the pedicle screw track and meeting the requirements for real-time fusion imaging. The proposed approach offers substantial support in surgical real-time navigation and ongoing monitoring within the domains of orthopedics and surgery.