Yuyang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuyang Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ronghui Wang
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
2 shared publications - Hengjie Zhao
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
1 shared publication - Niujing Ma
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
1 shared publication - Qinhe Li
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
1 shared publication - Yunwei Du
School of Traffic Engineering, Guangzhou Vocational College of Technology & Business, Guangzhou 511442, China
1 shared publication - Zhe Hu
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China
1 shared publication
Latest Publications
- Open Access
Research on the Elastic Stiffness of Stud–PBL Composite Shear Connectors in Composite Bridge Pylons
The application of steel–concrete composite structures in the pylons of long-span cable-stayed bridges can effectively address the issue of insufficient structural stiffness. Shear connectors are critical load-transfer components in steel–concrete composite segments, where they are typically arranged to ensure coordinated force transmission between steel and concrete. The stud–PBL composite shear connector, as a novel type of connector, has been implemented in engineering practice. However, the collaborative load-bearing performance between studs and PBL connectors remains unclear. Most shear connectors operate within the elastic stage during service, making their elastic stiffness a key evaluation metric. Based on the Winkler elastic foundation beam theory, plane strain theory, and the spring series–parallel model, this study derives the elastic stiffness calculation formulas for stud shear connectors and PBL shear connectors, respectively. The primary focus of this study was the single-layer stud–PBL composite shear connector within the steel–concrete composite section of bridge pylons. Embedded push-out tests were designed and conducted, comprising three main categories and eight subcategories. The load–slip curves for the three types of shear connectors were generated, and the stiffness calculation formula for the stud–PBL composite shear connector was verified through finite element analysis. The comparative push-out tests and finite element simulations demonstrate that the theoretical formula proposed in this study can effectively analyze the elastic stiffness of three types of shear connectors. The elastic stiffness of composite shear connectors can be regarded as the superposition of the elastic stiffness of studs and PBL shear connectors. Compared with single shear connectors, composite shear connectors exhibit superior elastic stiffness and shear resistance, meeting the application requirements of steel–concrete composite bridge pylons. The research findings provide a theoretical basis for the optimal design of shear connectors in large-span cable-stayed bridge composite pylons. Furthermore, the established formula has broad applicability.
Open AccessResearch on the Elastic Stiffness of Stud–PBL Composite Shear Connectors in Composite Bridge Pylons
The application of steel–concrete composite structures in the pylons of long-span cable-stayed bridges can effectively address the issue of insufficient structural stiffness. Shear connectors are critical load-transfer components in steel–concrete composite segments, where they are typically arranged to ensure coordinated force transmission between steel and concrete. The stud–PBL composite shear connector, as a novel type of connector, has been implemented in engineering practice. However, the collaborative load-bearing performance between studs and PBL connectors remains unclear. Most shear connectors operate within the elastic stage during service, making their elastic stiffness a key evaluation metric. Based on the Winkler elastic foundation beam theory, plane strain theory, and the spring series–parallel model, this study derives the elastic stiffness calculation formulas for stud shear connectors and PBL shear connectors, respectively. The primary focus of this study was the single-layer stud–PBL composite shear connector within the steel–concrete composite section of bridge pylons. Embedded push-out tests were designed and conducted, comprising three main categories and eight subcategories. The load–slip curves for the three types of shear connectors were generated, and the stiffness calculation formula for the stud–PBL composite shear connector was verified through finite element analysis. The comparative push-out tests and finite element simulations demonstrate that the theoretical formula proposed in this study can effectively analyze the elastic stiffness of three types of shear connectors. The elastic stiffness of composite shear connectors can be regarded as the superposition of the elastic stiffness of studs and PBL shear connectors. Compared with single shear connectors, composite shear connectors exhibit superior elastic stiffness and shear resistance, meeting the application requirements of steel–concrete composite bridge pylons. The research findings provide a theoretical basis for the optimal design of shear connectors in large-span cable-stayed bridge composite pylons. Furthermore, the established formula has broad applicability.
- Open Access
Experimental Study on the Force Mechanism of Internal Composite Connectors in Steel–Concrete Composite Sections of Bridge Towers
Current research on the stress mechanisms of composite connectors within steel–concrete structures of bridge towers is sparse, and there is a lack of established experimental methods and finite element modeling techniques for studying these mechanisms. This study focuses on a specific type of composite shear connector within the steel–concrete section of the Shunde Bridge tower. By employing proposed experimental methods and finite element model analysis, this research examines the load–slip curves and stress distribution of these shear connectors. It aims to elucidate the stress mechanisms and mechanical relationships between the composite connectors and the individual perforated plate connectors and shear stud connectors that comprise them. The results demonstrate that the proposed experimental methods and finite element modeling approaches effectively analyze the stress mechanisms of composite connectors, revealing that the ultimate load-bearing capacity and elastic stiffness of the composite connectors are approximately the sum of those of the individual connectors configured in parallel; The mechanical performance of the composite connectors in the steel–concrete section of the bridge tower is approximately the additive sum of the mechanical performances of the individual connectors comprising them. By comparing the experimentally measured load–slip curves with those calculated from the finite element models, it validates the modeling approach of the finite element model, and the material parameters established through material characteristic tests and literature review are reasonable.
Open AccessExperimental Study on the Force Mechanism of Internal Composite Connectors in Steel–Concrete Composite Sections of Bridge Towers
Current research on the stress mechanisms of composite connectors within steel–concrete structures of bridge towers is sparse, and there is a lack of established experimental methods and finite element modeling techniques for studying these mechanisms. This study focuses on a specific type of composite shear connector within the steel–concrete section of the Shunde Bridge tower. By employing proposed experimental methods and finite element model analysis, this research examines the load–slip curves and stress distribution of these shear connectors. It aims to elucidate the stress mechanisms and mechanical relationships between the composite connectors and the individual perforated plate connectors and shear stud connectors that comprise them. The results demonstrate that the proposed experimental methods and finite element modeling approaches effectively analyze the stress mechanisms of composite connectors, revealing that the ultimate load-bearing capacity and elastic stiffness of the composite connectors are approximately the sum of those of the individual connectors configured in parallel; The mechanical performance of the composite connectors in the steel–concrete section of the bridge tower is approximately the additive sum of the mechanical performances of the individual connectors comprising them. By comparing the experimentally measured load–slip curves with those calculated from the finite element models, it validates the modeling approach of the finite element model, and the material parameters established through material characteristic tests and literature review are reasonable.