CCClifford Ghee Ann Chua

Clifford Ghee Ann Chua

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clifford Ghee Ann Chua has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Hong Qi Tan

    Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Division of Physics and Applied Physics, School of Physical and Mathematical Science, Nanyang Technological University, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore

    5 shared publications
  • James Cheow Lei Lee

    Division of Physics and Applied Physics School of Physical and Mathematical Science Nanyang Technological University Singapore Singapore

    5 shared publications
  • Kah Seng Lew

    Division of Physics and Applied Physics School of Physical and Mathematical Science Nanyang Technological University Singapore Singapore

    5 shared publications
  • Sung Yong Park

    National Cancer Centre Singapore

    5 shared publications
  • Andrew Wibawa

    Division of Radiation Oncology, National Cancer Centre Singapore, Singapore

    4 shared publications
  • Wei Yang Calvin Koh

    Division of Radiation Oncology National Cancer Centre Singapore Singapore Singapore

    4 shared publications

Latest Publications

  • Ion recombination correction in reference dosimetry for pencil beam scanned proton beams

    by Jun Ken Gan, Kah Seng Lew, Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kang Hao Lee, Masashi Yagi, Wen Siang Lew, James Cheow Lei Lee, Sung Yong Park, Hong Qi Tan

    Background: The 2024 IAEA TRS‐398 revision updated recommendations for reference dosimetry and ion recombination corrections in pencil beam scanned (PBS) proton beams. Purpose: This study evaluates the revised ion recombination methods for monoenergetic synchrotron‐based PBS proton system across different energies, monitor units (MU), and ionization chamber types. Methods: Reference‐field measurements were performed using a synchrotron system at 70.2, 150.2, and 228.7 MeV and at 6, 50, and 200 MU. Charge‐collection data were acquired using PTW Farmer and Advanced Markus chambers across 20–400 V. Ion recombination correction factors () were determined using the Jaffé plot extrapolation method and the TRS‐398 two‐voltage method (TVM) under different time structure assumptions. Charge multiplication in the chamber was addressed using both low voltage linear fitting and a semiempirical exponential model. Results: For low energy, low MU fields, and TVM yielded values within ∼1% of the Jaffé extrapolation. For high‐energy, high‐MU fields, maximum differences of 6.25% (Farmer) and 1.62% (Advanced Markus) were observed. The synchrotron beam exhibited energy, MU, and chamber dependent time structure behavior, producing pulsed‐like or continuous‐like characteristics. Misclassification of the time structure resulted in additional deviations of up to 2.49% (Farmer) and 0.59% (Advanced Markus). Charge multiplication was observed in the Advanced Markus chamber at voltages > 150 V. The exponential fitting successfully modeled this response and produced values agreeing with low voltage fits within 1.5%, while avoiding subjective voltage cutoff selection. Conclusion: The revised TRS‐398 provides accurate ion recombination corrections for monoenergetic PBS fields at low energies and low MU. However, accuracy of ion recombination correction decreases at higher energies and MU, particularly when the time structure was ambiguous or chamber dependent. Charge multiplication in small volume chambers presents an additional source of uncertainty not fully addressed by TRS‐398. Incorporating charge multiplication fitting methods may improve the robustness of reference dosimetry in synchrotron‐based PBS proton therapy.

  • Open Access

    Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

    by Clifford Ghee Ann Chua, Wilson Han Yi Lim, Kang Hao Lee, Kah Seng Lew, Masashi Yagi, Wei Yang Calvin Koh, Andrew Wibawa, Zubin Master, Wen Siang Lew, James Cheow Lei Lee, et al.

  • Limitations of a fixed rise time model for beam delivery time prediction in dose-driven continuous scanning proton therapy

    by Kang Hao Lee, Clifford Ghee Ann Chua, Keith M. Furutani, Kah Seng Lew, Wei Yang Calvin Koh, Andrew Wibawa, Zubin Master, Masashi Yagi, James Cheow Lei Lee, Chris J. Beltran, et al.


  • Open Access

    Commissioning of LUNA three-dimensional surface-guided radiotherapy in full rotating gantry proton therapy system

    by Kah Seng Lew, James Kuan Huei Lee, Clifford Ghee Ann Chua, Wei Yang Calvin Koh, Jun Ken Gan, Andrew Wibawa, Zubin Master, Eric Pei Ping Pang, Wen Siang Lew, James Cheow Lei Lee, et al.


  • A comprehensive characterization of the temporal characteristics of dose driven continuous scanning in proton therapy

    by Clifford Ghee Ann Chua, Keith M Furutani, Kang Hao Lee, Kah Seng Lew, Calvin Wei Yang Koh, Andrew Wibawa, Zubin Master, Wen Siang Lew, James Cheow Lei Lee, Chris J Beltran, et al.

    Objective. To comprehensively characterize the temporal characteristics of dose-driven continuous scanning (DDCS) proton therapy system including the rise time to nominal beam current ( t rise ) , minimum time between break spot ( t b ) , beam current fluctuation and the flap dose. Approach. Measurements were performed on a Hitachi proton therapy synchrotron. The beam current fluctuation was measured using a 20 kHz 2D strip ionization chamber (CROSSmini) with a fixed point irradiation without break points (BPs). t rise , t b and flap dose were quantified using an oscilloscope connected to the radiofrequency knockout (RFK), high-speed switching magnet (HSST), and dose monitor signals. These measurements were performed with BPs. t rise was measured and compared using both the analytical log file based and direct measurement approaches. The measurements were performed across three energies (70.2, 150.2 and 228.7 MeV), three beam currents (8, 14 and 20 MU s−1) and five different spot MUs (6, 10, 20, 30 and 40 MU). Main results. The instantaneous beam current measured by CROSSmini showed fluctuations of up to 65%. After applying a 1.0 ms moving average, the beam current coincides with the log file recorded beam current, thereby validating the latter data. The time delay between RFK off and HSST on was (0.08 ± 0.01) ms and minimal flap dose was recorded with an average of 4 μMU. The minimum time between break spots was measured to be (1.67 ± 0.04) ms. The analytical log file-based and direct measurement of t rise were correlated with a Pearson correlation coefficient of 0.86. The t rise measurement across the entire spills showed a dependence on beam current where 8 MU s−1 had a notably higher t rise than 14 and 20 MU s−1. Significance. This is the first comprehensive study to characterize the temporal properties of a DDCS proton therapy system. The methodology introduced in this work would help in the proton DDCS commissioning efforts in other centers.