Pierre Mougenot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pierre Mougenot has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bogdan Gherman
CESTER, Technical University of Cluj-Napoca
4 shared publications - Doina Pisla
CESTER, Technical University of Cluj-Napoca
4 shared publications - Calin Vaida
CESTER, Technical University of Cluj-Napoca
3 shared publications - Damien Chablat
CESTER, Technical University of Cluj-Napoca
3 shared publications - Ionut Zima
CESTER, Technical University of Cluj-Napoca
3 shared publications - Adrian Pisla
Technical University of Cluj-Napoca
2 shared publications
Latest Publications
- 14 September 2026
- Published by Springer Nature
- p. 114-123
Control-Oriented Integration of a Spherical Parallel Robot for Minimally Invasive Surgery
- 14 September 2026
- Published by Springer Nature
- p. 114-123
Control-Oriented Integration of a Spherical Parallel Robot for Minimally Invasive Surgery
- Open Access
Modeling of a 4-DOF Flexible Laparoscopic Instrument for Robot-Assisted Minimally Invasive Surgery
Background: Flexible surgical instruments for Robot-Assisted Minimally Invasive Surgery (RAMIS) face a critical limitation: the inability to rotate the distal head while the instrument is in a bent configuration, which restricts the maneuverability in narrow surgical workspaces. Methods: This paper presents a novel 4-degree-of-freedom (DOF) flexible laparoscopic instrument with a 10 mm diameter, incorporating a 3D-printed flexible element. The design enables independent bending (0–90°), continuous distal head rotation (360°), gripper actuation (0–60°), and rod rotation (180°). A constant-curvature kinematic model was developed. The instrument was manufactured using PolyJet 3D printing technology and integrated with the ATHENA parallel robot for proof-of-concept experimental validation. Results: Experimental tests demonstrated successful independent 360° distal head rotation across the full bending range (0–90°), validated through simulated surgical procedures including stomach retraction. Quantitative characterization using optical motion capture revealed a maximum angular deflection of 79.85° at 670 g applied load, with tip displacements of 74.95 mm (X) and 91.18 mm (Y). The measured grasping force was approximately 2 N, tip position repeatability was ±2.86 mm, and fatigue testing demonstrated no degradation after 500 bending cycles, confirmed by digital microscope inspection. The instrument performed multiple manipulation tasks, including elastic band transfer, wire path navigation, spring manipulation, and tissue grasping. Conclusions: The proposed instrument addresses a significant white spot in surgical robotics by adding an additional functional capability enabling grasper reorientation without repositioning the entire instrument.
Open AccessModeling of a 4-DOF Flexible Laparoscopic Instrument for Robot-Assisted Minimally Invasive Surgery
Background: Flexible surgical instruments for Robot-Assisted Minimally Invasive Surgery (RAMIS) face a critical limitation: the inability to rotate the distal head while the instrument is in a bent configuration, which restricts the maneuverability in narrow surgical workspaces. Methods: This paper presents a novel 4-degree-of-freedom (DOF) flexible laparoscopic instrument with a 10 mm diameter, incorporating a 3D-printed flexible element. The design enables independent bending (0–90°), continuous distal head rotation (360°), gripper actuation (0–60°), and rod rotation (180°). A constant-curvature kinematic model was developed. The instrument was manufactured using PolyJet 3D printing technology and integrated with the ATHENA parallel robot for proof-of-concept experimental validation. Results: Experimental tests demonstrated successful independent 360° distal head rotation across the full bending range (0–90°), validated through simulated surgical procedures including stomach retraction. Quantitative characterization using optical motion capture revealed a maximum angular deflection of 79.85° at 670 g applied load, with tip displacements of 74.95 mm (X) and 91.18 mm (Y). The measured grasping force was approximately 2 N, tip position repeatability was ±2.86 mm, and fatigue testing demonstrated no degradation after 500 bending cycles, confirmed by digital microscope inspection. The instrument performed multiple manipulation tasks, including elastic band transfer, wire path navigation, spring manipulation, and tissue grasping. Conclusions: The proposed instrument addresses a significant white spot in surgical robotics by adding an additional functional capability enabling grasper reorientation without repositioning the entire instrument.
- 4 February 2026
- Published by Springer Nature
- p. 185-196
Development of an Innovative Parallel Robot Used in Laparoscopic Pancreatic Surgery
- 4 February 2026
- Published by Springer Nature
- p. 185-196
Development of an Innovative Parallel Robot Used in Laparoscopic Pancreatic Surgery
- 11 July 2025
- Published by Springer Nature
- p. 23-32
Review on Retractor Design to Enhance Minimally Invasive Pancreatectomy: Addressing Challenges in Deep Tissue Access
- 11 July 2025
- Published by Springer Nature
- p. 23-32
Review on Retractor Design to Enhance Minimally Invasive Pancreatectomy: Addressing Challenges in Deep Tissue Access